Interactive Time-of-use demand response for industrial electricity customers: A case study

被引:22
作者
Kholerdi, Somayeh Siahchehre [1 ]
Ghasemi-Marzbali, Ali [1 ]
机构
[1] Mazandaran Univ Sci & Technol, Dept Elect & Biomed Engn, Babol, Iran
关键词
Energy management; Interactive demand response; Time-of-use; Electric market;
D O I
10.1016/j.jup.2021.101192
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Demand response (DR) programs are regarded as one of the most reliable and reasonable methods to benefit electricity suppliers and consumers. This paper presents a modified approach to DR based on an Interactive Timeof-Use (ITOU) model by which volunteer industrial customers and their electricity suppliers obtain the best possible performance. Owing to this aim, when studying the region's electrical load profile to determine the peak-hours, the one-year production and sales profile of industrial customers is also studied to select off-peak hours for industrial subscribers. The results of program implementation for the selected and volunteer industrial customers at the sub-transmission level are presented to evaluate the performance of the proposed model. Considering the electricity bills of the subscribers in the program based on reduced energy consumption at peak hours (selected by the utility), and increased energy consumption at the off-peak price (selected by industrial customers), the economic benefits to industrial customers are calculated and verified. Plotting new load curves confirms load shifting from the peak to the valley of the load curve. The obtained results of the conventional TOU and ITOU models indicate that the proposed ITOU is more effective in achieving program goals.
引用
收藏
页数:12
相关论文
共 18 条
[1]   Demand response modeling considering Interruptible/Curtailable loads and capacity market programs [J].
Aalami, H. A. ;
Moghaddam, M. Parsa ;
Yousefi, G. R. .
APPLIED ENERGY, 2010, 87 (01) :243-250
[2]  
[Anonymous], 2013, Tech. Rep.
[3]  
[Anonymous], 2019, ASS DEM RESP ADV MET
[4]  
Artecon A., 2018, ENERGY RELIABILITY M
[5]  
Azman N.A. M., 2017, INDONESIAN J ELECT E, V6, P155
[6]  
Balasubramaniam V.K., 2021, INTELLIGENT PARADIGM
[7]  
BREF, 2010, EUROPEAN COMMISSION
[8]  
Brief K., 2011, FORTNIGHTLY MAGAZINE
[9]  
Gough M., 2020, ENERGIES, V13, P4332
[10]   Implementing Time-of-Use Demand Response Program in microgrid considering energy storage unit participation and different capacities of installed wind power [J].
Imani, Mahmood Hosseini ;
Niknejad, Payam ;
Barzegaran, M. R. .
ELECTRIC POWER SYSTEMS RESEARCH, 2019, 175