Methodological Aspects on Microdialysis Protein Sampling and Quantification in Biological Fluids: An In Vitro Study on Human Ventricular CSF

被引:42
作者
Dahlin, Andreas P. [1 ]
Wetterhall, Magnus [2 ]
Caldwell, Karin D. [2 ]
Larsson, Anders [3 ]
Bergquist, Jonas [2 ]
Hillered, Lars [4 ]
Hjort, Klas [1 ]
机构
[1] Uppsala Univ, Dept Engn Sci, SE-75121 Uppsala, Sweden
[2] Uppsala Univ, Dept Phys & Analyt Chem, SE-75124 Uppsala, Sweden
[3] Uppsala Univ, Univ Uppsala Hosp, Dept Med Sci, SE-75185 Uppsala, Sweden
[4] Uppsala Univ, Univ Uppsala Hosp, Dept Neurosci, SE-75185 Uppsala, Sweden
基金
瑞典研究理事会;
关键词
TRAUMATIC BRAIN-INJURY; HUMAN SKELETAL-MUSCLE; SURFACE INTERACTIONS; CEREBRAL MICRODIALYSIS; CEREBROSPINAL-FLUID; POLYETHYLENE OXIDE; RELATIVE RECOVERY; HUMAN SKIN; MEMBRANE; MACROMOLECULES;
D O I
10.1021/ac1007706
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is growing interest in sampling of protein biomarkers from the interstitial compartment of the brain and other organs using high molecular cutoff membrane microdialysis (MD) catheters. However, recent data suggest that protein sampling across such MD membranes is a highly complex process that needs to be further studied. Here, we report three major improvements for microdialysis sampling of proteins in complex biological matrixes. The improvements in this in vitro study using human ventricular cerebrospinal fluid as the sample matrix include increased fluid recovery control, decreased protein adsorption on the microdialysis membrane and materials, and novel quantitative mass spectrometry analysis. Dextrans in different concentrations and sizes were added to the perfusion fluid. It was found that dextrans with molecular mass 250 and 500 kDa provided a fluid recovery close to 100%. An improved fluid recovery precision could be obtained by self-assembly triblock polymer surface modification of the MD catheters. The modified catheters also delivered a significantly increased extraction efficiency for some of the investigated proteins. The final improvement was to analyze the dialysates with isobaric tagged (iTRAQ) proteomics, followed by tandem mass spectrometric analysis. By using this technique, 48 proteins could be quantified and analyzed with respect to their extraction efficiencies. The novel aspects of microdialysis protein sampling, detection, and quantification in biological fluids presented in this study should be considered as a first step toward better understanding and handling of the challenges associated with microdialysis sampling of proteins. The next step is to optimize the developed methodology in vivo.
引用
收藏
页码:4376 / 4385
页数:10
相关论文
共 49 条
  • [1] POLY(ETHYLENE OXIDE)-POLY(PROPYLENE OXIDE)-POLY(ETHYLENE OXIDE) BLOCK-COPOLYMER SURFACTANTS IN AQUEOUS-SOLUTIONS AND AT INTERFACES - THERMODYNAMICS, STRUCTURE, DYNAMICS, AND MODELING
    ALEXANDRIDIS, P
    HATTON, TA
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1995, 96 (1-2) : 1 - 46
  • [2] Foreign body reaction to biomaterials
    Anderson, James M.
    Rodriguez, Analiz
    Chang, David T.
    [J]. SEMINARS IN IMMUNOLOGY, 2008, 20 (02) : 86 - 100
  • [3] Microdialysis sampling of cytokines
    Ao, XP
    Stenken, JA
    [J]. METHODS, 2006, 38 (04) : 331 - 341
  • [4] Amyloid-β dynamics correlate with neurological status in the injured human brain
    Brody, David L.
    Magnoni, Sandra
    Schwetye, Kate E.
    Spinner, Michael L.
    Esparza, Thomas J.
    Stocchetti, Nino
    Zipfel, Gregory J.
    Holtzman, David M.
    [J]. SCIENCE, 2008, 321 (5893) : 1221 - 1224
  • [5] Utilizing transmembrane convection to enhance solute sampling and delivery by microdialysis: Theory and in vitro validation
    Bungay, Peter M.
    Wang, Tianli
    Yang, Hua
    Elmquist, William F.
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2010, 348 (1-2) : 131 - 149
  • [6] Membrane characterisation and performance of microdialysis probes intended for use as bioprocess sampling units
    Buttler, T
    Nilsson, C
    Gorton, L
    MarkoVarga, G
    Laurell, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 725 (01) : 41 - 56
  • [7] Biocompatible polymer materials: Role of protein-surface interactions
    Chen, Hong
    Yuan, Lin
    Song, Wei
    Wu, Zhongkui
    Li, Dan
    [J]. PROGRESS IN POLYMER SCIENCE, 2008, 33 (11) : 1059 - 1087
  • [8] 8-Plex quantitation of changes in cerebrospinal fluid protein expression in subjects undergoing intravenous immunoglobulin treatment for Alzheimer's disease
    Choe, Leila
    D'Ascenzo, Mark
    Relkin, Norman R.
    Pappin, Darryl
    Ross, Philip
    Williamson, Brian
    Guertin, Steven
    Pribil, Patrick
    Lee, Kelvin H.
    [J]. PROTEOMICS, 2007, 7 (20) : 3651 - 3660
  • [9] What can microdialysis tell us about the temporal and spatial generation of cytokines in allergen-induced responses in human skin in vivo?
    Clough, Geraldine F.
    Jackson, Claire L.
    Lee, Jacob J. P.
    Jamal, Sarah C.
    Church, Martin K.
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2007, 127 (12) : 2799 - 2806
  • [10] Microdialysis of large molecules
    Clough, GF
    [J]. AAPS JOURNAL, 2005, 7 (03) : E686 - E692