Accuracy of Three-Dimensional Photogrammetric Images in Non-Synostotic Cranial Deformities

被引:59
作者
Schaaf, H. [1 ,2 ]
Pons-Kuehnemann, J. [3 ]
Malik, C. Y. [1 ,2 ]
Streckbein, P. [1 ,2 ]
Preuss, M. [2 ,4 ]
Howaldt, H-P. [1 ,2 ]
Wilbrand, J-F. [1 ,2 ]
机构
[1] Univ Hosp Giessen, Dept Maxillofacial Surg, D-35385 Giessen, Germany
[2] Marburg GmbH, Marburg, Germany
[3] Univ Giessen, Inst Med Informat, D-35390 Giessen, Germany
[4] Univ Hosp Giessen, Dept Neurosurg, D-35385 Giessen, Germany
关键词
photogrammetry; three-dimensional imaging; anthropometry; error; plagiocephaly; CRANIOFACIAL TRAITS; INDIVIDUALS; ASYMMETRY; PRECISION; INFANTS;
D O I
10.1055/s-0030-1255060
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Given the increasing incidence of deformational plagiocephaly due to infants' supine sleeping position to prevent sudden infant death syndrome, reliable anthropometric diagnostics are needed. Besides the traditional method of measuring landmarks with callipers, three-dimensional (3D) photography has great potential. In this investigation the accuracy of 3D photogrammetry is studied. Methods: The study included 100 randomly chosen children between the ages of 4 and 20 months with a non-synostotic cranial deformity in a retrospective analysis. Measurements of diagonals A and B on the infant's head were obtained once using callipers. 3D photographs of these children were measured 5 times by 5 clinicians separately. Results: The inter- and intra-rater agreements of the 3D measurements had low variability in the variance component analysis. The standard deviations for reproducibility and repeatability were 0.117-0.283 cm for diagonals A and B. The intra-class correlation coefficients for the inter-rater reliability resulted in excellent agreement (0.97 for plagiocephaly, 0.98 for brachycephaly, 0.96 for combined deformity). The comparison of the 3D photographic and callipers measurements showed that 3D photography resulted in a slight over-estimation. Conclusion: 3D photogrammetry is potentially a reliable tool for treatment planning and follow-up of abnormal head shapes in infancy.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 37 条
  • [1] Precision and error of three-dimensional phenotypic measures acquired from 3dMD photogrammetric images
    Aldridge, K
    Boyadjiev, SA
    Capone, GT
    DeLeon, VB
    Richtsmeier, JT
    [J]. AMERICAN JOURNAL OF MEDICAL GENETICS PART A, 2005, 138A (03) : 247 - 253
  • [2] [Anonymous], 1994, Anthropometry of the head and face
  • [3] Validation of a vision-based, three-dimensional facial imaging system
    Ayoub, A
    Garrahy, A
    Hood, C
    White, J
    Bock, M
    Siebert, JP
    Spencer, R
    Ray, A
    [J]. CLEFT PALATE-CRANIOFACIAL JOURNAL, 2003, 40 (05) : 523 - 529
  • [4] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [5] PHOTOANTHROPOMETRIC STUDY OF CRANIOFACIAL TRAITS OF INDIVIDUALS WITH PRADER-WILLI-SYNDROME
    BUTLER, MG
    LEVINE, GJ
    LE, JY
    HALL, BD
    CASSIDY, SB
    [J]. AMERICAN JOURNAL OF MEDICAL GENETICS, 1995, 58 (01): : 38 - 45
  • [6] Butler MG, 1998, CLIN GENET, V53, P268
  • [7] Head moulding for plagiocephaly
    Carter, Michael R.
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 2008, 93 (09) : 809 - 810
  • [8] Towards computer assisted evaluation of plagiocephaly
    Donegan, HA
    OFlaherty, DC
    Kernohan, WG
    [J]. MEDICAL INFORMATICS, 1996, 21 (02): : 155 - 167
  • [9] Farkas LG, 1996, CLEFT PALATE-CRAN J, V33, P19
  • [10] Farkas LG, 1996, CLEFT PALATE-CRAN J, V33, P10, DOI 10.1597/1545-1569(1996)033<0010:AOAMPP>2.3.CO