Qualification of a fluorescence spectrometer for measuring true fluorescence spectra

被引:45
作者
DeRose, Paul C. [1 ]
Early, Edward A. [1 ]
Kramer, Gary W. [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
关键词
D O I
10.1063/1.2715952
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
New analytical methods using fluorescence detection are becoming increasingly quantitative and require easy-to-use material standards for fluorometer qualification and method validation. NIST is responding to this need by developing and producing such standards. Reported here is the first step in this process, which is to qualify a research-grade fluorescence spectrometer for measuring true fluorescence spectra of reference material candidates. "True" spectra are defined here as those with fluorescence intensity, either relative or absolute as required, and wavelength both being reported with high accuracy and known precision, after wavelength has been calibrated and corrections for excitation intensity and detection system response have been applied. The uncertainties determined in relative and absolute intensity-corrected fluorescence spectra using both calibrated source (CS)- and calibrated detector (CD)-based methods were compared. The CS-based method gave uncertainties, typically about +/- 5% for relative spectral correction, that were about half that of the CD-based method for determining both relative and absolute spectral correction factors. Absolute spectral correction factors can be determined using either method without knowing the optical geometry of the instrument. The absolute spectral correction factors were found to have much larger uncertainties than the corresponding relative correction factors with uncertainties for the CS-based method of +/- 10% to +/- 15% being typical and +/- 20% or more not being uncommon, particularly for excitation and emission wavelengths below 400 nm. Uncertainties arising from detection system nonlinearity and instrument polarization ratios were also explored.
引用
收藏
页数:12
相关论文
共 45 条
[1]  
[Anonymous], 2004, ANN BOOK ASTM STAND
[2]   POLARIZATION EFFECTS ON FLUORESCENCE MEASUREMENTS [J].
CEHELNIK, ED ;
MIELENZ, KD ;
VELAPOLDI, RA .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION A-PHYSICS AND CHEMISTRY, 1975, A 79 (01) :1-15
[3]  
COSTA LF, 1982, OPTICAL RAD MEASUREM, V3, P139
[4]  
DEROSE PC, 2000, J RES NATL INST STAN, V105, P631
[5]  
DEROSE PC, IN PRESS P 5 OXF C S
[6]   REFERENCE MATERIALS FOR FLUORESCENCE MEASUREMENT [J].
EATON, DF .
PURE AND APPLIED CHEMISTRY, 1988, 60 (07) :1107-1114
[7]   Quantitating fluorescence intensity from fluorophore: Assignment of MESF values [J].
Gaigalas, AK ;
Wang, LL ;
Schwartz, A ;
Marti, GE ;
Vogt, RF .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2005, 110 (02) :101-114
[8]   DETERMINATION OF THE WAVELENGTH POSITIONING ACCURACY OF A SEQUENTIAL SCANNING ICP SPECTROMETER [J].
GROSSER, ZA ;
COLLINS, JB .
APPLIED SPECTROSCOPY, 1991, 45 (06) :993-998
[9]  
GRUM F, 1972, J COLOR APPEARANCE, V1, P18
[10]  
*HAM PHOT KK, 2004, DAT SI PHOT S1226 SE