A CLINICAL SYSTEM FOR NON-INVASIVE BLOOD-BRAIN BARRIER OPENING USING A NEURONAVIGATION-GUIDED SINGLE-ELEMENT FOCUSED ULTRASOUND TRANSDUCER

被引:93
|
作者
Pouliopoulos, Antonios N. [1 ]
Wu, Shih-Ying [1 ]
Burgess, Mark T. [1 ]
Karakatsani, Maria Eleni [1 ]
Kamimura, Hermes A. S. [1 ]
Konofagou, Elisa E. [1 ,2 ]
机构
[1] Columbia Univ, Dept Biomed Engn, New York, NY USA
[2] Columbia Univ, Dept Radiol, New York, NY USA
基金
美国国家卫生研究院;
关键词
Blood-brain barrier; Focused ultrasound; Clinical system; Drug delivery; CONTRAST-AGENT; SHORT PULSES; CAVITATION; DISRUPTION; MICROBUBBLES; THERAPY; DRUG; THALAMOTOMY; ENHANCE; FLOW;
D O I
10.1016/j.ultrasmedbio.2019.09.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Focused ultrasound (FUS)-mediated blood-brain barrier (BBB) opening is currently being investigated in clinical trials. Here, we describe a portable clinical system with a therapeutic transducer suitable for humans, which eliminates the need for in-line magnetic resonance imaging (MRI) guidance. A neuronavigation-guided 0.25-MHz single-element FUS transducer was developed for non-invasive clinical BBB opening. Numerical simulations and experiments were performed to determine the characteristics of the FUS beam within a human skull. We also validated the feasibility of BBB opening obtained with this system in two non-human primates using U.S. Food and Drug Administration (FDA)-approved treatment parameters. Ultrasound propagation through a human skull fragment caused 44.4 +/- 1% pressure attenuation at a normal incidence angle, while the focal size decreased by 3.3 +/- 1.4% and 3.9 +/- 1.8% along the lateral and axial dimension, respectively. Measured lateral and axial shifts were 0.5 +/- 0.4 mm and 2.1 +/- 1.1 mm, while simulated shifts were 0.1 +/- 0.2 mm and 6.1 +/- 2.4 mm, respectively. A 1.5-MHz passive cavitation detector transcranially detected cavitation signals of Definity microbubbles flowing through a vessel-mimicking phantom. T-1-weighted MRI confirmed a 153 +/- 5.5 mm(3) BBB opening in two non-human primates at a mechanical index of 0.4, using Definity microbubbles at the FDA-approved dose for imaging applications, without edema or hemorrhage. In conclusion, we developed a portable system for non-invasive BBB opening in humans, which can be achieved at clinically relevant ultrasound exposures without the need for in-line MRI guidance. The proposed FUS system may accelerate the adoption of non-invasive FUS-mediated therapies due to its fast application, low cost and portability. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:73 / 89
页数:17
相关论文
共 50 条
  • [21] Magnetic Resonance-Guided Focused Ultrasound : Current Status and Future Perspectives in Thermal Ablation and Blood-Brain Barrier Opening
    Lee, Eun Jung
    Fomenko, Anton
    Lozano, Andres M.
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2019, 62 (01) : 10 - 26
  • [22] Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice
    Choi, James J.
    Pernot, Mathieu
    Small, Scott A.
    Konofagou, Elisa E.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (01) : 95 - 104
  • [23] Blood-brain barrier opening in Alzheimer's disease using MR-guided focused ultrasound
    Lipsman, Nir
    Meng, Ying
    Bethune, Allison J.
    Huang, Yuexi
    Lam, Benjamin
    Masellis, Mario
    Herrmann, Nathan
    Heyn, Chinthaka
    Aubert, Isabelle
    Boutet, Alexandre
    Smith, Gwenn S.
    Hynynen, Kullervo
    Black, Sandra E.
    NATURE COMMUNICATIONS, 2018, 9
  • [24] Transcranial MRI-guided focused ultrasound-induced blood-brain barrier opening in rats
    Treat, LH
    McDannold, N
    Vykhodtseva, N
    Hynynen, K
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 998 - 1000
  • [25] Non-invasive delivery of stealth, brain-penetrating nanoparticles across the blood - brain barrier using MRI-guided focused ultrasound
    Nance, Elizabeth
    Timbie, Kelsie
    Miller, G. Wilson
    Song, Ji
    Louttit, Cameron
    Klibanov, Alexander L.
    Shih, Ting-Yu
    Swaminathan, Ganesh
    Tamargo, Rafael J.
    Woodworth, Graeme F.
    Hanes, Justin
    Price, Richard J.
    JOURNAL OF CONTROLLED RELEASE, 2014, 189 : 123 - 132
  • [26] MRI-guided Disruption of the Blood-brain Barrier using Transcranial Focused Ultrasound in a Rat Model
    O'Reilly, Meaghan A.
    Waspe, Adam C.
    Chopra, Rajiv
    Hynynen, Kullervo
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2012, (61):
  • [27] Initial In Vivo Feasibility of a Pre-Clinical Focused Ultrasound System Applied to Blood-Brain Barrier Opening in Monkeys
    Marquet, Fabrice
    Tung, Yao-Sheng
    Teichert, Tobias
    Ferrera, Vincent
    Konofagou, Elisa E.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2001 - 2004
  • [28] Localized blood-brain barrier opening in infiltrating gliomas with MRI-guided acoustic emissions-controlled focused ultrasound
    Anastasiadis, Pavlos
    Gandhi, Dheeraj
    Guo, Yutong
    Ahmed, Abdul-Kareem
    Bentzen, Soren M.
    Arvanitis, Costas
    Woodworth, Graeme F.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2021, 118 (37)
  • [29] Nanosonosensitizer-Augmented Sono-Immunotherapy for Glioblastoma by Non-Invasive Opening of the Blood-Brain Barrier
    Lin, Danmin
    Wang, Zhen
    Long, Wei
    Xu, Mingze
    Liu, Aolu
    Gao, Yifei
    Wen, Zhu
    Liu, Chao
    He, Jiecheng
    Cheng, Yuxue
    Jiang, Siyuan
    Chen, Jiapeng
    Liu, Qingpeng
    Zhang, Lingkun
    You, Rong
    Yin, Liang
    Guan, Yanqing
    ADVANCED FUNCTIONAL MATERIALS, 2023, 33 (06)
  • [30] Bilateral-array focused ultrasound transducer with dual-frequency mode for blood-brain barrier opening in presence of microbubbles
    Wu, Sheng-Kai
    Lee, Pei-Chi
    Lee, Yung-Shin
    Wu, Xin-Yu
    Fu, Wen-Mei
    Lin, Win-Li
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 6, 2009, 25 : 16 - +