A Continuous Sample Drop Flow-Based Microextraction Method for Spectrophotometric Determination of Cobalt with 1-(2-Pyridylazo)-2-Naphthol in Water Samples

被引:7
作者
Ezati, Mohanna [1 ]
Moinfar, Soleyman [1 ,2 ]
Mohammadi, Somayeh [1 ,3 ]
Khayatian, Gholamreza [1 ]
机构
[1] Univ Kurdistan, Fac Sci, Dept Chem, POB 416, Sanandaj 6617715175, Iran
[2] Univ Zakho, Sci Res Ctr, Zakho, Iraq
[3] Kermanshah Univ Med Sci, Sch Publ Hlth, Res Ctr Environm Determinants Hlth RCEDH, Kermanshah, Iran
关键词
continuous sample drop flow-based microextraction; cobalt determination; 1-(2-pyridy1azo)-2-naphthol; real water samples; UV-Vis spectroscopy;
D O I
10.1134/S1061934821020076
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is always a need to develop new, fast and non-complicated microextraction methods that consume small amounts of organic solvents. In this study, a new mode of liquid phase microextraction method, termed as continuous sample drop flow-based microextraction (CSDF-ME), was developed for the enrichment and determination of cobalt in water samples. To attain the appropriate conditions for the CSDF-ME, experimental parameters such as pH, type and volume of extraction solvent, concentration of chelating agent, salting effect, sample flow rate and sample volume, needle diameter were examined. The enrichment factor was 167 for 20 mL sample solution. The calibration graph was linear in the concentration range of 5-200 mu g/L with the correlation coefficient of 0.999. The limit of detection was 1.3 mu g/L. The reliability of the recommended procedure was verified by analysis of real water samples (including tap, mineral and river water) and synthetic sample spiked with known amount of cobalt, and the obtained recoveries of spiked samples have demonstrated accuracy and applicability of the proposed method.
引用
收藏
页码:172 / 179
页数:8
相关论文
共 29 条
[1]   A procedure for determination of cobalt in water samples after dispersive liquid-liquid microextraction [J].
Baliza, Patricia Xavier ;
Gomes Teixeira, Leonardo Sena ;
Lemos, Valfredo Azevedo .
MICROCHEMICAL JOURNAL, 2009, 93 (02) :220-224
[2]  
Cheng K.L., 1982, Handbook of Organic Analytical Reagents
[3]   1-(2-PYRIDYLAZO)-2-NAPHTHOL AS A POSSIBLE ANALYTICAL REAGENT [J].
CHENG, KL ;
BRAY, RH .
ANALYTICAL CHEMISTRY, 1955, 27 (05) :782-785
[4]  
Elecková L, 2015, J ANAL CHEM+, V70, P298, DOI [10.7868/S0044450215030056, 10.1134/S1061934815030053]
[5]   Cloud point extraction for the determination of copper, nickel and cobalt ions in environmental samples by flame atomic absorption spectrometry [J].
Ghaedi, M. ;
Shokrollahi, A. ;
Ahmadi, F. ;
Rajabi, H. R. ;
Soylak, M. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 150 (03) :533-540
[6]   Dispersive liquid-liquid microextraction and spectrophotometric determination of cobalt in water samples [J].
Gharehbaghi, Maysam ;
Shemirani, Farzaneh ;
Baghdadi, Majid .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (07) :513-523
[7]   SPECTROPHOTOMETRIC DETERMINATION OF COBALT WITH 1-(2-PYRIDYLAZO)-2-NAPHTHOL - SEPARATION FROM INTERFERING IONS [J].
GOLDSTEIN, G ;
MANNING, DL ;
MENIS, O .
ANALYTICAL CHEMISTRY, 1959, 31 (02) :192-195
[8]   Ultrasonic assisted switchable solvent based on liquid phase microextraction combined with micro sample injection flame atomic absorption spectrometry for determination of some heavy metals in water, urine and tea infusion samples [J].
Habibiyan, Ahmad ;
Ezoddin, Maryam ;
Lamei, Navid ;
Abdi, Khosrou ;
Amini, Mohsen ;
Ghazi-khansari, Mahmoud .
JOURNAL OF MOLECULAR LIQUIDS, 2017, 242 :492-496
[9]   Determination of cobalt(II), nickel(II) and palladium(II) Ions via fabric phase sorptive extraction in combination with high-performance liquid chromatography-UV detection [J].
Heena ;
Kaur, Ramandeep ;
Rani, Susheela ;
Malik, Ashok Kumar ;
Kabir, Abuzar ;
Furton, Kenneth G. .
SEPARATION SCIENCE AND TECHNOLOGY, 2017, 52 (01) :81-90
[10]   Ultrasound-assisted hollow fiber/ionic liquid-based liquid phase microextraction using an ionic liquid solvent for preconcentration of cobalt and nickel ions in urine samples prior to FAAS determination [J].
Hsu, Keng-Chang ;
Lee, Cheng-Fa ;
Chao, Yu-Ying ;
Hung, Chih-Chang ;
Chen, Po-Chih ;
Chiang, Chien-Hua ;
Huang, Yeou-Lih .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (11) :2338-2345