Synergistic effects in mixed gas chromatographic stationary phases consisting of dibenzo-18-crown-6 and MPBHpB

被引:10
作者
Yuan, LM [1 ]
Fu, RN
Chen, XX
Gui, SH
机构
[1] Yunnan Normal Univ, Dept Chem, Kunming 650092, Peoples R China
[2] Beijing Inst Technol, Dept Chem Engn, Beijing 100081, Peoples R China
[3] Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650092, Peoples R China
关键词
gas chromatography; mixed stationary phases; dibenzo-18-crown-6; ether; MPBHpB; synergistic effects;
D O I
10.1007/BF02467498
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The synergistic effect is investigated in mixed gas chromatographic stationary phases containing dibenzo-18-crown-6 + MPBHpB [o-methyl-p-phenylene-bis-(p-heptoxy benzoate)], with benzene/cyclohexane, cyclohexane/hexane, halogenated hydrocarbons, aromatics, ketones, phenols, alcohols and aniline derivatives as sample compound pairs. Some of the separations reveal positive or negative synergistic effect. This effect depends on the temperature, the mixing ratio and the linear velocity of the carrier gas.
引用
收藏
页码:575 / 578
页数:4
相关论文
共 11 条
  • [1] UTILITY OF MIXED PACKINGS IN GAS-LIQUID-CHROMATOGRAPHY
    CHIEN, CF
    LAUB, RJ
    KOPECNI, MM
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (09) : 1402 - 1407
  • [2] USE OF COMBINATION COLUMNS IN GAS LIQUID CHROMATOGRAPHY
    HILDEBRAND, GP
    REILLEY, CN
    [J]. ANALYTICAL CHEMISTRY, 1964, 36 (01) : 47 - &
  • [3] Consequence of diluting modified beta-cyclodextrins in a side-chain crown ether polysiloxane and in a side-chain liquid-crystalline polysiloxane-containing crown ether as stationary phases in capillary gas chromatography
    Jing, P
    Fu, RN
    Dai, RJ
    Ge, JL
    Gu, JL
    Huang, Z
    Chen, Y
    [J]. CHROMATOGRAPHIA, 1996, 43 (9-10) : 546 - 550
  • [4] Lehn J. M., 1995, SUPRAMOLECULAR CHEM
  • [5] GAS-CHROMATOGRAPHIC RETENTION BEHAVIOR OF POLYCYCLIC AROMATIC-COMPOUNDS ON SMECTIC LIQUID-CRYSTALLINE POLYSILOXANE STATIONARY PHASES
    NISHIOKA, M
    JONES, BA
    TARBET, BJ
    BRADSHAW, JS
    LEE, ML
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 357 (01): : 79 - 91
  • [6] COMPARISON OF OLIGO(ETHYLENE OXIDE) SUBSTITUTED POLYSILOXANES WITH POLY(ETHYLENE GLYCOL) AS STATIONARY PHASES FOR CAPILLARY CHROMATOGRAPHY
    ROUSE, CA
    FINLINSON, AC
    TARBET, BJ
    PIXTON, JC
    DJORDJEVIC, NM
    MARKIDES, KE
    BRADSHAW, JS
    LEE, ML
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (09) : 901 - 905
  • [7] WITKIEWICZ Z, 1986, J CHROMATOGR, V357, P79
  • [8] PREPARATION AND CHARACTERISTICS OF A CROWN ETHER POLYSILOXANE STATIONARY PHASE FOR CAPILLARY GAS-CHROMATOGRAPHY
    WU, CY
    WANG, CM
    ZENG, ZR
    LU, XR
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (09) : 968 - 971
  • [9] XIAO DQ, 1997, CHROMATOGRAPHIA, V46, P183
  • [10] YUAN LM, 1990, HE HUAXUE YU FANGSHE, V12, P180