3D Catheter Guidance including Shape Sensing for Endovascular Navigation

被引:8
|
作者
Jaeckle, Sonja [1 ]
Garcia-Vazquez, Veronica [2 ]
von Haxthausen, Felix [2 ]
Eixmann, Tim [3 ]
Sieren, Malte Maria [4 ]
Schulz-Hildebrandt, Hinnerk [3 ,5 ,6 ]
Huttmann, Gereon [3 ,5 ,6 ]
Ernst, Floris [2 ]
Kleemann, Markus [7 ]
Paetz, Torben [8 ]
机构
[1] Inst Digital Med, Fraunhofer MEVIS, Lubeck, Germany
[2] Univ Lubeck, Inst Robot & Cognit Syst, Lubeck, Germany
[3] Med Laserzentrum Lubeck GmbH, Lubeck, Germany
[4] UKSH, Dept Radiol & Nucl Med, Lubeck, Germany
[5] Univ Lubeck, Inst Biomed Opt, Lubeck, Germany
[6] DZL, German Ctr Lung Res, Grohansdorf, Germany
[7] UKSH, Dept Surg, Lubeck, Germany
[8] Inst Digital Med, Fraunhofer MEVIS, Bremen, Germany
来源
MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING | 2021年 / 11315卷
关键词
catheter guidance; electromagnetic tracking; fiber Bragg gratings; shape sensing; endovascular navigation; endovascular aneurysm repair; ELECTROMAGNETIC TRACKING; ANEURYSM REPAIR;
D O I
10.1117/12.2548094
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, fluoroscopy and conventional digital subtraction angiography are used for imaging guidance in endovascular aortic repair (EVAR) procedures. Drawbacks of these image modalities are X-ray exposure, the usage of contrast agents and the lack of depth information. To overcome these disadvantages, a catheter prototype containing a multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape was built in this study. Furthermore, a model for processing the input data from the tracking systems to obtain the located 3D shape of the first 38 cm of the catheter was introduced: A spatial calibration between the optical fiber and each EM sensor was made in a calibration step and used to obtain the located shape of the catheter in subsequent experiments. The evaluation of our shape localization method with the catheter prototype in different shapes resulted in average errors from 0.99 to 2.29 mm and maximum errors from 1.73 to 2.99 mm. The experiments showed that an accurate shape localization with a multicore fiber and three EM sensors is possible, and that this catheter guidance is promising for EVAR procedures. Future work will be focused on the development of catheter guidance based on shape sensing with a multicore fiber, and the orientation and position of less than three EM sensors.
引用
收藏
页数:9
相关论文
共 40 条
  • [31] Femtosecond Laser Aided Processing of Optical Sensor Fibers for 3D Medical Navigation and Tracking (FiberNavi)
    Waltermann, Christian
    Koch, Jan
    Angelmahr, Martin
    Schade, Wolfgang
    Witte, Michael
    Kohn, Nils
    Wilhelm, Dirk
    Schneider, Armin
    Reiser, Silvano
    Feussner, Hubertus
    23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2014, 9157
  • [32] Virtual Angioscopy and 3D Navigation: A New Technique for Analysis of the Aortic Arch after Vascular Surgery
    Louis, N.
    Bruguiere, E.
    Kobeiter, H.
    Desgranges, P.
    Allaire, E.
    Kirsch, M.
    Becquemin, J. P.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 40 (03) : 340 - 347
  • [33] Feasibility of an endovascular training and research environment with exchangeable patient specific 3D printed vascular anatomy Simulator with exchangeable patient-specific 3D-printed vascular anatomy for endovascular training and research
    Kaschwich, Mark
    Sieren, Malte
    Matysiak, Florian
    Bouchagiar, Juljan
    Dell, Annika
    Bayer, Andreas
    Ernst, Floris
    Ellebrecht, David
    Kleemann, Markus
    Horn, Marco
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2020, 231
  • [34] Polymer optical Bend Sensor based on eccentric Fiber Bragg Gratings for 3D Shape Detection
    Leffers, Lennart
    Roth, Bernhard
    Overmeyer, Ludger
    ORGANIC PHOTONIC MATERIALS AND DEVICES XXIV, 2022, 11998
  • [35] Planning the use of endografts in the endovascular repair of complex abdominal and thoraco-abdominal aortic lesions leveraging 3D printing
    Mazzaccaro, Daniela
    Sturla, Francesco
    Rosato, Antonio
    Righini, Paolo
    Nano, Giovanni
    EXPERT REVIEW OF MEDICAL DEVICES, 2024, 21 (12) : 1121 - 1130
  • [36] 3D Printing of an Aortic Aneurysm to Facilitate Decision Making and Device Selection for Endovascular Aneurysm Repair in Complex Neck Anatomy
    Tam, Matthew D. B. S.
    Laycock, Stephen D.
    Brown, James R. I.
    Jakeways, Matthew
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (06) : 863 - 867
  • [37] Multislice CT Angiography in the Follow-up of Fenestrated Endovascular Grafts: Effect of Slice Thickness on 2D and 3D Visualization of the Fenestration Stents
    Sun, Zhonghua
    Allen, Yvonne B.
    Mwipatayi, Bibombe P.
    Hartley, David E.
    Lawrence-Brown, Michael M. D.
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (04) : 417 - 426
  • [38] A versatile intensity-based 3D/2D rigid registration compatible with mobile C-arm for endovascular treatment of abdominal aortic aneurysm
    A. Duménil
    A. Kaladji
    M. Castro
    C. Göksu
    A. Lucas
    P. Haigron
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 1713 - 1729
  • [39] A versatile intensity-based 3D/2D rigid registration compatible with mobile C-arm for endovascular treatment of abdominal aortic aneurysm
    Dumenil, A.
    Kaladji, A.
    Castro, M.
    Goksu, C.
    Lucas, A.
    Haigron, P.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (09) : 1713 - 1729
  • [40] Three-Dimensional Holographic Guidance, Navigation, and Control (3D-GNC) for Endograft Positioning in Porcine Aorta: Feasibility Comparison With 2-Dimensional X-Ray Fluoroscopy
    West, Karl
    Al-Nimer, Sara
    Goel, Vikash R.
    Yanof, Jeffrey H.
    Hanlon, Aydan T.
    Weunski, Crew J.
    Kattar, Jackie
    Farivar, Behzad S.
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (05) : 796 - 803