3D Catheter Guidance including Shape Sensing for Endovascular Navigation

被引:8
|
作者
Jaeckle, Sonja [1 ]
Garcia-Vazquez, Veronica [2 ]
von Haxthausen, Felix [2 ]
Eixmann, Tim [3 ]
Sieren, Malte Maria [4 ]
Schulz-Hildebrandt, Hinnerk [3 ,5 ,6 ]
Huttmann, Gereon [3 ,5 ,6 ]
Ernst, Floris [2 ]
Kleemann, Markus [7 ]
Paetz, Torben [8 ]
机构
[1] Inst Digital Med, Fraunhofer MEVIS, Lubeck, Germany
[2] Univ Lubeck, Inst Robot & Cognit Syst, Lubeck, Germany
[3] Med Laserzentrum Lubeck GmbH, Lubeck, Germany
[4] UKSH, Dept Radiol & Nucl Med, Lubeck, Germany
[5] Univ Lubeck, Inst Biomed Opt, Lubeck, Germany
[6] DZL, German Ctr Lung Res, Grohansdorf, Germany
[7] UKSH, Dept Surg, Lubeck, Germany
[8] Inst Digital Med, Fraunhofer MEVIS, Bremen, Germany
来源
MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING | 2021年 / 11315卷
关键词
catheter guidance; electromagnetic tracking; fiber Bragg gratings; shape sensing; endovascular navigation; endovascular aneurysm repair; ELECTROMAGNETIC TRACKING; ANEURYSM REPAIR;
D O I
10.1117/12.2548094
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, fluoroscopy and conventional digital subtraction angiography are used for imaging guidance in endovascular aortic repair (EVAR) procedures. Drawbacks of these image modalities are X-ray exposure, the usage of contrast agents and the lack of depth information. To overcome these disadvantages, a catheter prototype containing a multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape was built in this study. Furthermore, a model for processing the input data from the tracking systems to obtain the located 3D shape of the first 38 cm of the catheter was introduced: A spatial calibration between the optical fiber and each EM sensor was made in a calibration step and used to obtain the located shape of the catheter in subsequent experiments. The evaluation of our shape localization method with the catheter prototype in different shapes resulted in average errors from 0.99 to 2.29 mm and maximum errors from 1.73 to 2.99 mm. The experiments showed that an accurate shape localization with a multicore fiber and three EM sensors is possible, and that this catheter guidance is promising for EVAR procedures. Future work will be focused on the development of catheter guidance based on shape sensing with a multicore fiber, and the orientation and position of less than three EM sensors.
引用
收藏
页数:9
相关论文
共 40 条
  • [21] Shape sensing of 3D frame structures using an inverse Finite Element Method
    Gherlone, Marco
    Cerracchio, Priscilla
    Mattone, Massimiliano
    Di Sciuva, Marco
    Tessler, Alexander
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2012, 49 (22) : 3100 - 3112
  • [22] Nonfluoroscopic 3D Image Guidance System Reduces Navigation Times Through Five 3D-Printed Iliofemoral Vascular Phantoms
    Braga, Daniel
    Ducaud, Cristobal
    Camardo, Andrew
    Hofacker, Hannah
    Goel, Vikash
    Beasley, Robert
    JOURNAL OF ENDOVASCULAR THERAPY, 2023,
  • [23] 3D printing in the planning and teaching of endovascular procedures
    Stana, J.
    Grab, M.
    Kargl, R.
    Tsilimparis, N.
    RADIOLOGIE, 2022, 62 (SUPPL 1): : S28 - S33
  • [24] 3D shape sensing of an epidural needle based on simultaneous spatial multiplexing of optical backscattering reflectometry
    Molardi, Carlo
    Beisenova, Aidana
    Issatayeva, Aizhan
    Blanc, Wilfried
    Tosi, Daniele
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XX, 2020, 11233
  • [25] Fusion Imaging to Guide Thoracic Endovascular Aortic Repair (TEVAR): A Randomized Comparison of Two Methods, 2D/3D Versus 3D/3D Image Fusion
    Barral, P. -A.
    Demasi-Jacquier, M. A.
    Bal, L.
    Omnes, V.
    Bartoli, A.
    Piquet, P.
    Jacquier, A.
    Gaudry, M.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (11) : 1522 - 1529
  • [26] Pros and Cons of 3D Image Fusion in Endovascular Aortic Repair: A Systematic Review and Meta-analysis
    Goudeketting, Seline R.
    Heinen, Stefan G. H.
    Unlu, Cagdas
    van den Heuvel, Daniel A. F.
    de Vries, Jean-Paul P. M.
    van Strijen, Marco J.
    Sailer, Anna M.
    JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (04) : 595 - 603
  • [27] Using of 3D Virtual Reality Electromagnetic Navigation for Challenging Cannulation in FEVAR Procedure
    Piazza, Roberta
    Condino, Sara
    Alberti, Aldo
    Giannetti, Davide
    Ferrari, Vincenzo
    Gesi, Marco
    Ferrari, Mauro
    AUGMENTED REALITY, VIRTUAL REALITY, AND COMPUTER GRAPHICS, AVR 2017, PT II, 2017, 10325 : 221 - 229
  • [28] Dynamic Validation of a Strain-Based 3-D Shape Sensing System
    Di Napoli, Isaac
    Harwood, Casey M.
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2020, 2020, 11379
  • [29] 3D Shape Sensing With Multicore Optical Fibers: Transformation Matrices Versus Frenet-Serret Equations for Real-Time Application
    Paloschi, Davide
    Bronnikov, Kirill A.
    Korganbayev, Sanzhar
    Wolf, Alexey A.
    Dostovalov, Alexander
    Saccomandi, Paola
    IEEE SENSORS JOURNAL, 2021, 21 (04) : 4599 - 4609
  • [30] 3D Contrast Enhanced Ultrasound for Detecting Endoleak Following Endovascular Aneurysm Repair (EVAR)
    Abbas, A.
    Hansrani, V.
    Sedgwick, N.
    Ghosh, J.
    McCollum, C. N.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 47 (05) : 487 - 492