3D Catheter Guidance including Shape Sensing for Endovascular Navigation

被引:8
|
作者
Jaeckle, Sonja [1 ]
Garcia-Vazquez, Veronica [2 ]
von Haxthausen, Felix [2 ]
Eixmann, Tim [3 ]
Sieren, Malte Maria [4 ]
Schulz-Hildebrandt, Hinnerk [3 ,5 ,6 ]
Huttmann, Gereon [3 ,5 ,6 ]
Ernst, Floris [2 ]
Kleemann, Markus [7 ]
Paetz, Torben [8 ]
机构
[1] Inst Digital Med, Fraunhofer MEVIS, Lubeck, Germany
[2] Univ Lubeck, Inst Robot & Cognit Syst, Lubeck, Germany
[3] Med Laserzentrum Lubeck GmbH, Lubeck, Germany
[4] UKSH, Dept Radiol & Nucl Med, Lubeck, Germany
[5] Univ Lubeck, Inst Biomed Opt, Lubeck, Germany
[6] DZL, German Ctr Lung Res, Grohansdorf, Germany
[7] UKSH, Dept Surg, Lubeck, Germany
[8] Inst Digital Med, Fraunhofer MEVIS, Bremen, Germany
来源
MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING | 2021年 / 11315卷
关键词
catheter guidance; electromagnetic tracking; fiber Bragg gratings; shape sensing; endovascular navigation; endovascular aneurysm repair; ELECTROMAGNETIC TRACKING; ANEURYSM REPAIR;
D O I
10.1117/12.2548094
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, fluoroscopy and conventional digital subtraction angiography are used for imaging guidance in endovascular aortic repair (EVAR) procedures. Drawbacks of these image modalities are X-ray exposure, the usage of contrast agents and the lack of depth information. To overcome these disadvantages, a catheter prototype containing a multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape was built in this study. Furthermore, a model for processing the input data from the tracking systems to obtain the located 3D shape of the first 38 cm of the catheter was introduced: A spatial calibration between the optical fiber and each EM sensor was made in a calibration step and used to obtain the located shape of the catheter in subsequent experiments. The evaluation of our shape localization method with the catheter prototype in different shapes resulted in average errors from 0.99 to 2.29 mm and maximum errors from 1.73 to 2.99 mm. The experiments showed that an accurate shape localization with a multicore fiber and three EM sensors is possible, and that this catheter guidance is promising for EVAR procedures. Future work will be focused on the development of catheter guidance based on shape sensing with a multicore fiber, and the orientation and position of less than three EM sensors.
引用
收藏
页数:9
相关论文
共 40 条
  • [1] Three-dimensional guidance including shape sensing of a stentgraft system for endovascular aneurysm repair
    Jaeckle, Sonja
    Garcia-Vazquez, Veronica
    Eixmann, Tim
    Matysiak, Florian
    von Haxthausen, Felix
    Sieren, Malte Maria
    Schulz-Hildebrandt, Hinnerk
    Huettmann, Gereon
    Ernst, Floris
    Kleemann, Markus
    Paetz, Torben
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2020, 15 (06) : 1033 - 1042
  • [2] Three-dimensional guidance including shape sensing of a stentgraft system for endovascular aneurysm repair
    Sonja Jäckle
    Verónica García-Vázquez
    Tim Eixmann
    Florian Matysiak
    Felix von Haxthausen
    Malte Maria Sieren
    Hinnerk Schulz-Hildebrandt
    Gereon Hüttmann
    Floris Ernst
    Markus Kleemann
    Torben Pätz
    International Journal of Computer Assisted Radiology and Surgery, 2020, 15 : 1033 - 1042
  • [3] Improved Catheter Navigation With 3D Electromagnetic Guidance
    Cochennec, Frederic
    Riga, Celia
    Hamady, Mohamad
    Cheshire, Nicholas
    Bicknell, Colin
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (01) : 39 - 47
  • [4] Improved 3D Catheter Shape Estimation Using Ultrasound Imaging for Endovascular Navigation: A Further Study
    Chen, Fang
    Liu, Jia
    Zhang, Xinran
    Zhang, Daoqiang
    Liao, Hongen
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (12) : 3616 - 3629
  • [5] 3D Catheter Shape Determination for Endovascular Navigation Using a Two-Step Particle Filter and Ultrasound Scanning
    Chen, Fang
    Liu, Jia
    Liao, Hongen
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (03) : 685 - 695
  • [6] Fiber optical shape sensing of flexible instruments for endovascular navigation
    Jaeckle, Sonja
    Eixmann, Tim
    Schulz-Hildebrandt, Hinnerk
    Huettmann, Gereon
    Paetz, Torben
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (12) : 2137 - 2145
  • [7] Fiber optical shape sensing of flexible instruments for endovascular navigation
    Sonja Jäckle
    Tim Eixmann
    Hinnerk Schulz-Hildebrandt
    Gereon Hüttmann
    Torben Pätz
    International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 2137 - 2145
  • [8] 3D small strain large deflection beam shape sensing including poisson effect
    Schaefer, Pierre-Loup
    Chagnon, Gregory
    Moreau-Gaudry, Alexandre
    ENGINEERING STRUCTURES, 2020, 209
  • [9] Estimation of 2D/3D rigid transformation for Computer-assisted Endovascular Navigation
    Castro, Miguel
    Goeksu, Cemil
    Haigron, Pascal
    Lucas, Antoine
    Urbano, Luis
    2008 3RD INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGIES: FROM THEORY TO APPLICATIONS, VOLS 1-5, 2008, : 1099 - +
  • [10] 2D and 3D Shape Sensing Based on 7-Core Fiber Bragg Gratings
    Lai, Tianting
    Cheng, Pu
    Yan, Congliao
    Li, Chi
    Hu, Wenbin
    Yang, Minghong
    PHOTONIC SENSORS, 2020, 10 (04) : 306 - 315