Adenosine stress protocols for myocardial perfusion imaging

被引:21
作者
Bokhari, Sabahat [1 ]
Ficaro, Edward P. [1 ]
McCallister, Benjamin D., Jr. [1 ]
机构
[1] Amer Soc Nucl Cardiol, Bethesda, MD 20814 USA
关键词
D O I
10.1016/j.nuclcard.2007.04.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although there are no large randomized, blinded, prospective trials comparing 3- or 4-minute protocols with the 6-minute adenosine infusion protocol, there has been a history of clinical use of a 4-minute protocol with favorable results. Kinetic data for adenosine define that the minimum time to injection of tracer should be 2 minutes to provide adequate time to achieve maximal vasodilation, and that the maximal vasodilation should continue for 2 minutes to ensure adequate uptake for both Tc-99m- and Tl-201-labeled radiotracers. © 2007 American Society of Nuclear Cardiology.
引用
收藏
页码:415 / 416
页数:2
相关论文
共 16 条
[1]  
ABREU A, 1990, CIRCULATION, V82, P730
[2]   TOLERANCE AND SAFETY OF PHARMACOLOGICAL CORONARY VASODILATION WITH ADENOSINE IN ASSOCIATION WITH TL-201 SCINTIGRAPHY IN PATIENTS WITH SUSPECTED CORONARY-ARTERY DISEASE [J].
ABREU, A ;
MAHMARIAN, JJ ;
NISHIMURA, S ;
BOYCE, TM ;
VERANI, MS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) :730-735
[3]  
DEPUEY EG, 2006, IMAGING GUIDELINES N
[4]  
GUPTA N, 1990, Journal of Nuclear Medicine, V31, P733
[5]   COMPARISON OF THE MYOCARDIAL UPTAKE OF A TECHNETIUM-LABELED ISONITRILE ANALOG AND THALLIUM [J].
LEPPO, JA ;
MEERDINK, DJ .
CIRCULATION RESEARCH, 1989, 65 (03) :632-639
[6]  
MAHMARIAN J J, 1989, Journal of Nuclear Medicine, V30, P760
[7]  
MAHMARIAN JJ, 1989, CIRCULATION S2, V80, P308
[8]   SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY WITH TL-201 DURING ADENOSINE-INDUCED CORONARY HYPEREMIA - CORRELATION WITH CORONARY ARTERIOGRAPHY, EXERCISE THALLIUM IMAGING AND 2-DIMENSIONAL ECHOCARDIOGRAPHY [J].
NGUYEN, T ;
HEO, J ;
OGILBY, JD ;
ISKANDRIAN, AS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (06) :1375-1383
[9]  
NISHIMURA S, 1990, CIRCULATION, V82, P731
[10]   MYOCARDIAL KINETICS OF TECHNETIUM-99M-HEXAKIS-2-METHOXY-2-METHYLPROPYL-ISONITRILE [J].
OKADA, RD ;
GLOVER, D ;
GAFFNEY, T ;
WILLIAMS, S .
CIRCULATION, 1988, 77 (02) :491-498