Near-infrared spectroscopy and indocyanine green derived blood flow index for noninvasive measurement of muscle perfusion during exercise

被引:51
作者
Habazettl, Helmut [1 ,2 ]
Athanasopoulos, Dimitris [3 ,4 ]
Kuebler, Wolfgang M. [1 ,2 ]
Wagner, Harrieth [5 ]
Roussos, Charis [3 ]
Wagner, Peter D. [5 ]
Ungruhe, Juergen [1 ]
Zakynthinos, Spyros [3 ]
Vogiatzis, Ioannis [3 ,4 ]
机构
[1] Charite CBF, Inst Physiol, D-14195 Berlin, Germany
[2] German Heart Inst, Inst Anesthesiol, Berlin, Germany
[3] Univ Athens, M Simou & GP Livanos Labs, Evangelismos Hosp, Dept Crit Care Med & Pulm Serv, Athens, Greece
[4] Univ Athens, Dept Phys Educ & Sport Sci, Athens, Greece
[5] Univ Calif San Diego, Dept Med, La Jolla, CA 92093 USA
关键词
exercise; Fick principle; interobserver variability; NIRS; PULSE DYE DENSITOMETRY; NEWBORN PIGLETS;
D O I
10.1152/japplphysiol.01269.2009
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Habazettl H, Athanasopoulos D, Kuebler WM, Wagner H, Roussos C, Wagner PD, Ungruhe J, Zakynthinos S, Vogiatzis I. Near-infrared spectroscopy and indocyanine green derived blood flow index for noninvasive measurement of muscle perfusion during exercise. J Appl Physiol 108: 962-967, 2010. First published January 28, 2010; doi: 10.1152/japplphysiol.01269.2009.-Near-infrared spectroscopy (NIRS) with the tracer indocyanine green (ICG) may be used for measuring muscle blood flow (MBF) during exercise, if arterial ICG concentration is measured simultaneously. Although pulse dye densitometry allows for noninvasive measurement of arterial dye concentration, this technique is sensitive to motion and may not be applicable during exercise. The aim of this study was to evaluate a noninvasive blood flow index (BFI), which is derived solely from the muscle ICG concentration curve. In 10 male cyclists 5 mg ICG were injected into an antecubital vein at rest and during cycling at 30, 60, 70, 80, 90, and 100% of previously determined maximal work load. Simultaneously blood was withdrawn through a photodensitometer at 20 ml/min from the radial artery to measure arterial ICG concentration. To measure muscle tissue ICG concentrations, two sets of NIRS optodes were positioned on the skin, one over the left seventh intercostal space and the other over the left vastus lateralis muscle. MBF was calculated from the arterial and muscle concentration data according to Fick's principle. BFI was calculated solely from the muscle concentration curve as ICG concentration difference divided by rise time between 10 and 90% of peak. During exercise mean BFI values changed similarly to MBF in both intercostal and quadriceps muscles and showed excellent correlations with MBF: r = 0.98 and 0.96, respectively. Individual data showed some scattering among BFI and MBF values but still reasonable correlations of BFI with MBF: r = 0.73 and 0.72 for intercostal and quadriceps muscles, respectively. Interobserver variability, as analyzed by Bland-Altman plots, was considerably less for BFI than MBF. These data suggest that BFI can be used for measuring changes in muscle perfusion from rest to maximal exercise. Although absolute blood flow cannot be determined, BFI has the advantages of being essentially noninvasive and having low interobserver variability.
引用
收藏
页码:962 / 967
页数:6
相关论文
共 50 条
[21]   In vivo quantitative near-infrared spectroscopy in skeletal muscle during incremental isometric handgrip exercise [J].
van Beekvelt, MCP ;
van Engelen, BGM ;
Wevers, RA ;
Colier, WNJM .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2002, 22 (03) :210-217
[22]   Heterogeneity of blood flow and metabolism in exercising muscle by near-infrared spectroscopy (NIRS) in COPD patients [J].
Louvaris, Zafeiris ;
Vogiatzis, Ioannis ;
Habazettl, Helmut ;
Asimakos, Andreas ;
Wagner, Harrieth ;
Zakynthinos, Spyros ;
Wagner, Peter .
EUROPEAN RESPIRATORY JOURNAL, 2015, 46
[23]   Near-infrared spectroscopy-derived muscle oxygen saturation during exercise recovery and flow-mediated dilation are impaired in HIV-infected patients [J].
Volino-Souza, Monica ;
de Oliveira, Gustavo Vieira ;
Barros-Santos, Elisa ;
Pinheiro, Vivian ;
Machado-Santos, Ana Paula ;
Conte-Junior, Carlos A. ;
Alvares, Thiago Silveira .
MICROVASCULAR RESEARCH, 2020, 130
[24]   Noninvasive measurement of postocclusive parameters in human forearm blood by near infrared spectroscopy [J].
Rao, KP ;
Radhakrishnan, S ;
Reddy, MR .
Third International Conference on Experimental Mechanics and Third Conference of the Asian-Committee-on-Experimental-Mechanics, Pts 1and 2, 2005, 5852 :443-447
[25]   Noninvasive tissue blood oxygenation measurement based on near infrared spectroscopy (NIRS) [J].
Cao, Ning ;
Gao, Tianxin .
2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, :1346-1349
[26]   The influence of cardiovascular risk factors on near-infrared spectroscopy-derived muscle oxygen saturation during exercise recovery in older adults [J].
Gustavo Vieira de Oliveira ;
Mônica Volino-Souza ;
Elisa Barros-Santos ;
Carlos Adam Conte-Junior ;
Thiago Silveira Alvares .
Sport Sciences for Health, 2022, 18 :1221-1228
[27]   The influence of cardiovascular risk factors on near-infrared spectroscopy-derived muscle oxygen saturation during exercise recovery in older adults [J].
de Oliveira, Gustavo Vieira ;
Volino-Souza, Monica ;
Barros-Santos, Elisa ;
Conte-Junior, Carlos Adam ;
Alvares, Thiago Silveira .
SPORT SCIENCES FOR HEALTH, 2022, 18 (04) :1221-1228
[28]   Near-infrared spectroscopy during exercise and recovery in children with juvenile dermatomyositis [J].
Habers, G. Esther A. ;
De Knikker, Rogier ;
Van Brussel, Marco ;
Hulzebos, Erik ;
Stegeman, Dick F. ;
Van Royen, Annet ;
Takken, Tim .
MUSCLE & NERVE, 2013, 47 (01) :108-115
[29]   Epinephrine iontophoresis attenuates changes in skin blood flow and abolishes cutaneous contamination of near-infrared diffuse correlation spectroscopy estimations of muscle perfusion [J].
Bartlett, Miles F. ;
Palmero-Canton, Alberto ;
Oneglia, Andrew P. ;
Mireles, Julissa ;
Brothers, Matthew ;
Trowbridge, Cynthia A. ;
Wilkes, Dustin ;
Nelson, Michael D. .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY, INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2023, 324 (03) :R368-R380
[30]   A method for assessing heterogeneity of blood flow and metabolism in exercising normal human muscle by near-infrared spectroscopy [J].
Vogiatzis, Ioannis ;
Habazettl, Helmut ;
Louvaris, Zafeiris ;
Andrianopoulos, Vasileios ;
Wagner, Harrieth ;
Zakynthinos, Spyros ;
Wagner, Peter D. .
JOURNAL OF APPLIED PHYSIOLOGY, 2015, 118 (06) :783-793