Stress Distribution in Cortical Bone around the Basal Implant - A Finite Element Analysis

被引:1
作者
Roy, Anip Kumar [1 ]
Dixit, Nivedita [1 ]
Punde, Prashant [2 ]
Sinha, Koshika Tondon [3 ]
Jalaluddin, Mohammad [4 ]
Kumar, Ashish
机构
[1] Inst Dent Sci, Dept Prosthodont, Baeilly, Uttar Pradesh, India
[2] Krishna Inst Med Sci Deemed Univ, Sch Dent Sci, Dept Oral & Maxillofacial Surg, Karad, Maharashtra, India
[3] Purvanchal Inst Dent Sci, Dept Prosthodont, Gorakhpur, Uttar Pradesh, India
[4] KIIT Deemed Univ, Kalinga Inst Dent Sci, Dept Periodont & Oral Implantol, Bhubaneswar, Odisha, India
来源
JOURNAL OF PHARMACY AND BIOALLIED SCIENCES | 2021年 / 13卷 / 05期
关键词
Basal implant; cortical bone; finite element analysis; stress;
D O I
10.4103/jpbs.JPBS_679_20
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim: The aim of the study was to develop a model that represents a basal implant with stress distribution in the cortical bone on application of loads emulating masticatory forces. Materials and Methods: In this study, the stress distribution in the bone and the implant is evaluated by applying various loads that emulate the masticatory forces. The geometric models of cortical bone representing the premolar area and a basal implant model of the following specifications, longitudinal oval threaded pin (1.95 mm x 2.1/2.3 mm o), height of the implant head (7.2 mm), and width of the implant head (3.5 mm) (BOI BS, IDHEDENTAL), were generated with Ansys software, and both the implant model and the bone model are superimposed to mimic the bone implant system as a unit. Results: Overall comparison of stress distribution on both implant shaft and implant neck showed that maximum stresses are located at implant neck irrespective of forces applied and minimum stresses are located at implant shaft. On overall comparison of stresses seen within the bone and the implant, it was observed that the maximum stresses were seen in the implant neck followed by the implant shaft followed by the bone interface. Conclusion: The present study concluded that the stress transmission is greatest during application of oblique load (70 N) followed by horizontal load (10 N) and the least by vertical load (35 N).
引用
收藏
页码:633 / 636
页数:4
相关论文
共 50 条
  • [41] Effect of Implant Design on Stress Distribution: A Finite Element Study
    Houshmand B.
    Ardakani M.T.
    Moscowchi A.
    Oskoui I.Z.
    Journal of Long-Term Effects of Medical Implants, 2022, 32 (04) : 39 - 45
  • [42] Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis
    Pinar Ercal
    Aysegul Erten Taysi
    Demet Cagil Ayvalioglu
    Meltem Mert Eren
    Soner Sismanoglu
    Medical & Biological Engineering & Computing, 2021, 59 : 813 - 824
  • [43] Effect of implant systems in differing bone densities on peri-implant bone stress: A 3 dimensional finite element analysis
    Sahi, Aoujashwie
    Gali, Sivaranjani
    MATERIALS TODAY-PROCEEDINGS, 2022, 50 : 1300 - 1307
  • [44] Assessment of Stress Shielding around a Dental Implant for Variation of Implant Stiffness and Parafunctional Loading using Finite Element Analysis
    Ishak, Muhammad Ikman
    Daud, Ruslizam
    Noor, Siti Noor Fazliah Mohd
    Khor, C. Y.
    Roslan, Husniyati
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2022, 24 (03) : 147 - 159
  • [45] Bone-Implant Interface with Simulated Insertion Stress Around an Immediately Loaded Dental Implant in the Anterior Maxilla: A Three-Dimensional Finite Element Analysis
    Lee, Joon-Seok
    Cho, In-Ho
    Kim, Yung-Soo
    Heo, Seong-Joo
    Kwon, Ho-Beom
    Lim, Young-Jun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (02) : 295 - 302
  • [46] Influence of insertion depth on stress distribution in orthodontic miniscrew and the surrounding bone by finite element analysis
    Hirai, Yuzo
    Watanabe, Keiichiro
    Deguchi, Toru
    Ueda, Kanji
    Hamada, Kenichi
    Tanaka, Eiji
    DENTAL MATERIALS JOURNAL, 2021, 40 (05) : 1270 - 1276
  • [47] A Comparative Evaluation of Stress Distribution Around Different Widths of Implant and Bony Interface in Function During Axial and Non-axial Loading: A Finite Element Analysis
    Pai, Deepika R.
    Prabhu, Damodar M.
    Sameeh, Abdul
    Soman, Ajay
    Thomas, Anjana
    Koruthu, Anil Varghese
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (06)
  • [48] Stress Distribution on Short Implants at Maxillary Posterior Alveolar Bone Model With Different Bone-to-Implant Contact Ratio: Finite Element Analysis
    Yazicioglu, Duygu
    Bayram, Burak
    Oguz, Yener
    Cinar, Duygu
    Uckan, Sina
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (01) : 27 - 33
  • [49] Finite Element Analysis of Bone Stress for Miniscrew Implant Proximal to Root Under Occlusal Force and Implant Loading
    Shan, Li-Hua
    Guo, Na
    Zhou, Guan-jun
    Qie, Hui
    Li, Chen-Xi
    Lu, Lin
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (07) : 2072 - 2076
  • [50] Comparison of Stress and Strain Distribution Patterns in Canine Implant and Maxillary Bone in Three Occlusal Schemes Using Finite Element Analysis
    Fathi, Amirhossein
    Hoshyar, Younes
    Ebadian, Behnaz
    Ghorbani, Mahsa
    EUROPEAN JOURNAL OF DENTISTRY, 2024, 18 (03) : 852 - 859