Impact of continuous and intermittent supply of electric assistance on high-strength 2,4-dichlorophenol (2,4-DCP) degradation in electro-microbial system

被引:31
|
作者
Cao, Zhanping [1 ]
Zhang, Minghui [1 ]
Zhang, Jingli [2 ]
Zhang, Hongwei [1 ]
机构
[1] Tianjin Polytech Univ, Sch Environm & Chem Engn, Tianjin 300387, Peoples R China
[2] Tianjin Chengjian Univ, Sch Environm & Municipal Engn, Tianjin 300384, Peoples R China
关键词
Continuously electro-microbial system (CEMS); Intermittently electro-microbial system (IEMS); 2,4-DCP hydrolysis; Zero-order reaction; Microbial characteristics; SLUDGE; HYDROPHOBICITY; BIOSTIMULATION; SUBSTANCES; COMMUNITY; BEHAVIOR; ACID;
D O I
10.1016/j.biortech.2016.03.165
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The high-strength 2,4-DCP, which exists in two states: dissolved and colloidal, was studied by a continuously electro-microbial system (CEMS) and an intermittently electro-microbial system (IEMS). The hydrolysis rate of colloidal 2,4-DCP in the IEMS without electric assistance was much higher than that in the CEMS. However, the degradation rate of the dissolved 2,4-DCP and the dissolved intermediates (2-chlorophenol and 4-chlorophenol) in the IEMS without electric assistance were much lower than that in the CEMS. By adjusting the intermittent operation mode, the degradation time of 2,4-DCP was shortened greatly. Microbial characteristics in the CEMS and the IEMS were different. The correlation analysis for the main factors affecting the hydrolysis was performed by SPSS, and it was found that the correlation coefficient (tau(p)) was -0.912 for extracellular polymeric substances (EPS) content, 0.823 for zeta potential and 0.632 for relative hydrophobicity, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:138 / 143
页数:6
相关论文
共 5 条
  • [1] Glutathione S-Transferase Activity in Wild Plants with 2,4-Dichlorophenol (2,4-DCP) Phytoremediation Potential
    Moharramzadeh, Mohammad
    Ceylan, Zeynep
    Atici, Okkes
    ANALYTICAL LETTERS, 2023, 56 (03) : 411 - 421
  • [2] A high activity of Ti/SnO2-Sb electrode in the electrochemical degradation of 2,4-dichlorophenol in aqueous solution
    Niu, Junfeng
    Maharana, Dusmant
    Xu, Jiale
    Chai, Zhen
    Bao, Yueping
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2013, 25 (07) : 1424 - 1430
  • [3] Simultaneously degradation of 2,4-Dichlorophenol and EDTA in aqueous solution by the bimetallic Cu-Fe/O2 system
    Liu, Xin
    Fan, Jin-Hong
    Ma, Lu-Ming
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (02) : 1186 - 1198
  • [4] Complete degradation of 2,4-dichlorophenol in a sequential sulfidated nanoscale zero-valent iron/peroxydisulfate system: dechlorination, mineralization and mechanism
    Pi, Zhoujie
    Zhou, Puyu
    Luo, Kun
    He, Li
    Chen, Shengjie
    Wang, Zhu
    Zhang, Shanshan
    Li, Xiaoming
    Yang, Qi
    ENVIRONMENTAL SCIENCE-NANO, 2025, 12 (02) : 1414 - 1430
  • [5] Impact of different zero valent iron-based particles on anaerobic microbial dechlorination of 2,4-dichlorophenol: Comparison of dechlorination performance and the underlying mechanism
    Ri, Cholnam
    Li, Fengxiang
    Mun, Hyokchol
    Liu, Linan
    Tang, Jingchun
    JOURNAL OF HAZARDOUS MATERIALS, 2023, 458