Point-of-care hip ultrasound leads to expedited results in emergency department patients with suspected septic arthritis

被引:15
|
作者
Thom, Christopher [1 ]
Ahmed, Azhar [1 ]
Kongkatong, Matthew [1 ]
Moak, James [1 ]
机构
[1] Univ Virginia Hlth Syst, Emergency Med, Charlottesville, VA USA
关键词
atraumatic hip pain; hip arthrocentesis; hip ultrasound; joint effusion; septic arthritis; toxic synovitis; transient synovitis; GUIDED ARTHROCENTESIS; TRANSIENT SYNOVITIS; PAINFUL HIP; DIAGNOSIS; ULTRASONOGRAPHY; INFECTIONS; MANAGEMENT; CRITERIA; EFFUSION; CHILDREN;
D O I
10.1002/emp2.12167
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BackgroundThe evaluation of septic hip arthritis often incorporates the utilization of hip ultrasonography to determine the presence of a hip joint effusion, as well as to guide arthrocentesis. Point-of-care (POC) hip ultrasound has previously been demonstrated to be accurate when performed by the emergency physician. Time to diagnosis and subsequent intervention in septic arthritis (SA) is critical to favorable outcomes. MethodsRetrospective single-center study of all emergency department (ED) patients who had a POC or radiology hip ultrasound or arthrocentesis as part of their ED evaluation for SA in a 3-year period. We investigated the difference in time to obtain hip ultrasonography results and the time to arthrocentesis between radiology and emergency physician-performed studies in cases of suspected septic hip arthritis. ResultsSeventy-four patients met inclusion criteria. The median time to hip ultrasound completion was 68 (interquartile range [IQR], 38.8-132) minutes in the emergency physician-performed ultrasound group versus 208.5 (IQR, 163.8-301.3) minutes for the radiology group (P < 0.001). A total of 17 patients had a hip arthrocentesis performed. Time to arthrocentesis was 211 (IQR 141.3-321.5) minutes in the emergency physician-performed arthrocentesis group and 602 (IQR 500-692) minutes in the radiology arthrocentesis (P < 0.001). ConclusionThere was a statistically shorter time to ultrasound result and arthrocentesis when POC hip ultrasound was utilized by the emergency physician. Given that unfavorable outcomes in SA are associated with delay in treatment, further study is warranted to determine if emergency physician-performed hip ultrasound and arthrocentesis could lead to improved patient-centered clinical end points.
引用
收藏
页码:512 / 520
页数:9
相关论文
共 50 条
  • [21] The use of point-of-care ultrasound for detection of retinal detachment in emergency department
    Sung, Kai Man
    Li, Chi
    Chiu, King Yung
    Chan, Ho Yin
    Lee, Ping Chung Gordon
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2024, : 354 - 359
  • [22] Point-of-Care Ultrasound Could Streamline the Emergency Department Workflow of Clinically Nonspecific Intussusception
    Kim, Jung Heon
    Lee, Jeong-Yong
    Kwon, Jae Hyun
    Cho, Hyung-Rae
    Lee, Jong Seung
    Ryu, Jeong-Min
    PEDIATRIC EMERGENCY CARE, 2020, 36 (02) : E90 - E95
  • [23] Point-of-care ultrasound for stroke patients in the emergency room
    Takekawa, Hidehiro
    Tsukui, Daisuke
    Kobayasi, Saro
    Suzuki, Keisuke
    Hamaguchi, Hirotoshi
    JOURNAL OF MEDICAL ULTRASONICS, 2022, 49 (04) : 581 - 592
  • [24] Point-of-care ultrasound findings in unselected patients in an emergency department -results from a prospective observational trial
    Weile, Jesper
    Laursen, Christian B.
    Frederiksen, Christian A.
    Graumann, Ole
    Sloth, Erik
    Kirkegaard, Hans
    BMC EMERGENCY MEDICINE, 2018, 18
  • [25] Emergency Point-of-Care Ultrasound Detection of Papilledema in the Pediatric Emergency Department
    Ben-Yakov, Maxim
    Desjardins, Marie-Pier
    Fischer, Jason W. J.
    PEDIATRIC EMERGENCY CARE, 2015, 31 (11) : 766 - 770
  • [26] Point-Of-Care Ultrasound for Lung Assessment in Patients With Severe Scoliosis and Chest Deformities: An Emergency Department Case Series
    de Castro Giorno, Eliana Paes
    Preto-Zamperlini, Marcela
    Weerdenburg, Kirstin
    Ferraz, Isabel de Siqueira
    Leite, Marcia Marques
    Lima Farhat, Sylvia Costa
    Schvartsman, Claudio
    JOURNAL OF EMERGENCY MEDICINE, 2020, 58 (05) : 775 - 780
  • [27] Point-of-Care Ultrasound for Pediatric Vaginal Obstruction in the Emergency Department
    Sosa, Philip
    Tsung, James W.
    Firnberg, Maytal
    PEDIATRIC EMERGENCY CARE, 2024, 40 (10) : 753 - 756
  • [28] A Systemic Review on the Diagnostic Accuracy of Point-of-Care Ultrasound in Patients With Undifferentiated Shock in the Emergency Department
    Berg, Ingvar
    Walpot, Kris
    Lamprecht, Hein
    Valois, Maxime
    Lanctot, Jean-Francois
    Srour, Nadim
    van den Brand, Crispijn
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [29] Point-of-care Ultrasound to Evaluate Breast Pathology in the Emergency Department
    Acuna, Josie
    Pierre, Cubby M.
    Sorenson, Jacob
    Adhikari, Srikar
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2021, 22 (02) : 284 - 290
  • [30] Use of Cardiac Point-of-Care Ultrasound in the Pediatric Emergency Department
    Miller, Andrew F.
    Arichai, Piyawat
    Gravel, Cynthia A.
    Vieira, Rebecca L.
    Neal, Jeffrey T.
    Neuman, Mark, I
    Monuteaux, Michael C.
    Levy, Jason A.
    PEDIATRIC EMERGENCY CARE, 2022, 38 (01) : E300 - E305