Three-dimensional graphene-like homogeneous carbon architecture loaded with gold-platinum for the electrochemical detection of circulating tumor DNA

被引:12
作者
Chen, K. C. [1 ]
Zhao, H. L. [1 ]
Wang, Z. X. [1 ]
Lan, M. B. [1 ,2 ]
机构
[1] East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] East China Univ Sci & Technol, Res Ctr Anal & Test, Shanghai 200237, Peoples R China
关键词
Tumor biomarker; Three-dimensional architecture; Graphene-like carbon; Gold-platinum alloy; Electrochemical biosensor; CELL-FREE DNA; HYDROGEN-PEROXIDE; LIQUID BIOPSY; CANCER; PERFORMANCE; NANOPARTICLES; SPECTROSCOPY; IMMUNOASSAY; OXIDATION; EFFICIENT;
D O I
10.1016/j.mtchem.2022.100892
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The analysis of circulating tumor DNA (ctDNA) turns out to be increasingly significant considering its potential value in the clinical diagnosis of cancer. Herein, a ctDNA electrochemical biosensor was developed with a low detection limit and high selectivity by using three-dimensional graphene-like homogeneous carbon architecture (3D-GHC600) loaded with gold-platinum (AuPt). The 3D-GHC600 was derived from the annealing process of copper-based metal-organic framework (denoted as Cu-BTC) at the optimal temperature (600 ?), which includes the merits of large area, rich mesopores, homogeneous size and morphology, and 3D structure. AuPt was formed on the 3D-GHC(600) surface via an in-situ reduction reaction. Characterizations demonstrated that the resultant composite catalyst (AuPt/3DGHC600) was prepared successfully and exhibited remarkable electrochemical properties. Further, the catalyst was used as a label of signal probes (SPs) to form SPs-label. The hybridization reactions were completed by layer-by-layer recognition of capture probes (CPs), target DNA (tDNA), and SPs-label on the electrode, thus forming a sandwich-like structure. The current signals of the SPs-label toward the electrocatalytic reduction of H2O2 were recorded in all tests for tDNA analysis. Accordingly, this recommended biosensor of tDNA showed good performance including a wide linear range of 10(-8) M 10(-17) M with a detection limit of 2.25 x 10-18 M (S/N = 3), excellent selectivity for the recognition of different interferences, satisfying reproducibility, good stability, and outstanding recovery. These results demonstrated the promising application of the biosensor in the detection of ctDNA. (C)& nbsp;2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:11
相关论文
共 59 条
[1]   Liquid biopsy in ovarian cancer using circulating tumor DNA and cells: Ready for prime time? [J].
Asante, Du-Bois ;
Calapre, Leslie ;
Ziman, Melanie ;
Meniawy, Tarek M. ;
Gray, Elin S. .
CANCER LETTERS, 2020, 468 :59-71
[2]   Developing a Low-Cost, Simple-to-Use Electrochemical Sensor for the Detection of Circulating Tumour DNA in Human Fluids [J].
Attoye, Bukola ;
Pou, Chantevy ;
Blair, Ewen ;
Rinaldi, Christopher ;
Thomson, Fiona ;
Baker, Matthew J. ;
Corrigan, Damion K. .
BIOSENSORS-BASEL, 2020, 10 (11)
[3]  
Cai Chunyan, 2018, Nanotheranostics, V2, P12, DOI 10.7150/ntno.22419
[4]   3D graphene-based foam induced by phytic acid: An effective enzyme-mimic catalyst for electrochemical detection of cell-released superoxide anion [J].
Cai, Xuan ;
Chen, Huilan ;
Wang, Zhenxing ;
Sun, Wenqian ;
Shi, Libo ;
Zhao, Hongli ;
Lan, Minbo .
BIOSENSORS & BIOELECTRONICS, 2019, 123 :101-107
[5]   Rapid and ultrasensitive electrochemical detection of circulating tumor DNA by hybridization on the network of gold-coated magnetic nanoparticles [J].
Chen, Dongfei ;
Wu, Yanfang ;
Hoque, Sharmin ;
Tilley, Richard D. ;
Gooding, J. Justin .
CHEMICAL SCIENCE, 2021, 12 (14) :5196-5201
[6]   Size-Controlled Synthesis of Platinum-Copper Hierarchical Trigonal Bipyramid Nanoframes [J].
Chen, Sheng ;
Su, Hongyang ;
Wang, Youcheng ;
Wu, Wenlong ;
Zeng, Jie .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2015, 54 (01) :108-113
[7]   A review on C1s XPS-spectra for some kinds of carbon materials [J].
Chen, Xiangnan ;
Wang, Xiaohui ;
Fang, De .
FULLERENES NANOTUBES AND CARBON NANOSTRUCTURES, 2020, 28 (12) :1048-1058
[8]   Effect of electrode configuration on the sensitivity of nucleic acid detection in a non-planar, flow-through, porous interdigitated electrode [J].
Cheng, Yu-Hsuan ;
Moura, Pedro Antonio Reis ;
Li Zhenglong ;
Feng, Lixin ;
Arokiam, Siril ;
Yang, Juliana ;
Hariharan, Mahima ;
Basuray, Sagnik .
BIOMICROFLUIDICS, 2019, 13 (06)
[9]   High-Performance Nucleic Acid Sensors for Liquid Biopsy Applications [J].
Das, Jagotamoy ;
Kelley, Shana O. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2020, 59 (07) :2554-2564
[10]   DNA Clutch Probes for Circulating Tumor DNA Analysis [J].
Das, Jagotamoy ;
Ivanov, Ivaylo ;
Sargent, Edward H. ;
Kelley, Shana O. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2016, 138 (34) :11009-11016