Experimental study on demountable steel ultra-high performance concrete composite slabs under hogging moment

被引:5
作者
Guo, Jun-Yuan [1 ]
Wang, Jun-Yan [1 ,3 ]
Wang, Yan-Bo [2 ]
Gao, Xiao-Long [1 ]
Bian, Chen [1 ]
机构
[1] Tongji Univ, Key Lab Adv Civil Engn Mat, Minist Educ, Shanghai 201804, Peoples R China
[2] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
[3] Tongji Univ, Sch Mat Sci & Engn, 4800 Caoan Rd, Shanghai, Peoples R China
基金
中国博士后科学基金;
关键词
Composite slab; Ultra-high performance concrete; Flexural behavior; Demountable shear connectors; Hogging moment; PRECAST CONCRETE; SHEAR CONNECTORS; BEHAVIOR; TESTS;
D O I
10.1007/s43452-022-00458-w
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Demountable steel-concrete composite structures have attracted much attention from researchers because of its fast construction, demountability and environmental friendliness. Using ultra-high performance concrete (UHPC) in the hogging moment regions of demountable steel-concrete composite structures might improve their crack resistance and flexural performance. In this study, the cracking behavior, failure mode, stiffness, ultimate strength and relative slip of demountable steel-UHPC composite slabs with different stud spacings and longitudinal reinforcement ratios under hogging moment were experimentally investigated. A welded steel-UHPC composite slab was also tested to compare its behavior with the demountable slabs. The test results show the demountable steel-UHPC composite slabs have excellent crack control ability under hogging moment due to the slip of threaded headed stud and the strain hardening behavior of UHPC; the relative slip is directly associated with the stud spacing and controlled by the friction and shear force of threaded headed studs. As compared to the welded composite slab, the demountable composite slab can be easily separated after loading, the flexural capacity is slightly smaller, while the crack control ability is better and the ductility is higher. A constitutive model considering the reduction of tensile strength of UHPC after reinforcement was adoptedl the design formulas were developed to predict the elastic limit and the ultimate moment, and the bending stiffness of the demountable composite slabs under hogging moment. The test results verify the applicability of the proposed constitutive model of UHPC and design formulas.
引用
收藏
页数:24
相关论文
共 47 条
[1]  
[Anonymous], 2016, RECOMMENDATION ULTRA
[2]  
[Anonymous], 2009, BS EN 12350-2:2009
[3]  
[Anonymous], 2005, Load and resistance factor design specification for structural steel buildings
[4]  
[Anonymous], 2004, EN 1994-1-1
[5]  
[Anonymous], 2014, Standard Test Methods for Determining Average Grain Size, P1, DOI 10.1520/C0469
[6]  
[Anonymous], 2009, 1235032009 BS EN
[7]  
[Anonymous], 2020, Technical Requirements for Ultra High Performance Concrete
[8]  
[Anonymous], 2013, ULTRA HIGH PERFORMAN
[9]   Mechanical and damage mechanisms of reinforced ultra high performance concrete under tensile loading [J].
Bian, Chen ;
Wang, Jun-Yan .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 226 :259-279
[10]   Tension stiffening and cracking of steel fiber-reinforced concrete [J].
Bischoff, PH .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2003, 15 (02) :174-182