Quantitative imaging of iodine-131 distributions in brain tumors with pinhole SPECT: A phantom study

被引:0
作者
Smith, MF
Gilland, DR
Coleman, RE
Jaszczak, RJ
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Biomed Engn, Durham, NC 27710 USA
关键词
pinhole collimator; SPECT; iodine-131; imaging; brain tumor; radioimmunotherapy;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
method of quantitatively imaging I-131 distributions in brain tumors from intratumoral administration of activity was developed and investigated using pinhole SPECT of brain tumor phantoms, Methods: Pinhole SPECT sensitivity and resolution were characterized using I-131 point-source acquisitions with high-resolution lead (1.4-mm diameter aperture) and tungsten (1.0-mm diameter aperture) pinhole inserts. SPECT scans were obtained from brain tumor phantoms in a water-filled cylinder. The tumor phantoms consisted of spheres filled with an I-131 solution to model intratumoral administration of radiolabeled monoclonal antibodies. Two spheres were 20.5 and 97 mi, and two other concentric spheres modeled a tumor with a high-activity shell (71.5 ml) and a low-activity core (21 ml). The collimator focal length was 16 cm and the distance from the pinhole to the center of rotation was 13 cm, The filtered backprojection reconstruction algorithm incorporated scatter and attenuation compensation. SPECT tumor activities and concentrations were estimated using scaling factors from reference point-source scans. Results: System sensitivities for point sources at the center of rotation were 28.4 cts/sec(-1) MBq(-1) (lead insert) and 13.6 cts/sec(-1) MBq(-1) (tungsten insert). SPECT resolutions (FWHM) at the center of rotation were 8.1-11.9 mm (lead) and 6.7-10.3 mm (tungsten). Total tumor activity estimates from SPECT were within 17% of the true activities. SPECT activity concentration estimates in small regions of interest (ROIs) averaged -20% for the 20.5-ml sphere, -11 % for the 97-ml sphere, -39% for the shell and +20% for the core of the shell-core phantom. Activity spillover due to limited spatial resolution and the tails of the system response functions biased the estimates. The shell-to-core activity concentration ratio of 4.1 was better estimated with the tungsten insert (2.3) than with the lead insert (1.9) due to better resolution. Conclusion: Pinhole SPECT is a promising technique for imaging and quantifying total I-131 activity in regions the size of brain tumors. Relative errors were greater for activity concentration estimates in small ROIs than for total activity estimates.
引用
收藏
页码:856 / 864
页数:9
相关论文
共 50 条
[41]   The magnitude of the partial volume effect in SPECT imaging of the kidneys: a phantom study [J].
Andreas Grings ;
Camille Jobic ;
Torsten Kuwert ;
Philipp Ritt .
EJNMMI Physics, 9
[42]   Volume reduction versus radiation dose for tumors in previously untreated lymphoma patients who received iodine-131 tositumomab therapy - Conjugate views compared with a hybrid method [J].
Koral, KF ;
Francis, IR ;
Kroll, S ;
Zasadny, KR ;
Kaminski, MS ;
Wahl, RL .
CANCER, 2002, 94 (04) :1258-1263
[43]   Design and Evaluation of a Portable Pinhole SPECT System for 177Lu Imaging: Monte Carlo Simulations and Experimental Study [J].
Savvidis, Georgios ;
Eleftheriadis, Vasileios ;
Paneta, Valentina ;
Fysikopoulos, Eleftherios ;
Georgiou, Maria ;
Lamprou, Efthimis ;
Lagoumtzi, Sofia ;
Loudos, George ;
Katsakiori, Paraskevi ;
Kagadis, George C. ;
Papadimitroulas, Panagiotis .
DIAGNOSTICS, 2025, 15 (11)
[44]   Comparative Study of Two Oxidizing Agents, Chloramine T and Iodo-Gen®, for the Radiolabeling of β-CIT with Iodine-131: Relevance for Parkinson's Disease [J].
Durante, Ana Claudia R. ;
Sobral, Danielle V. ;
Miranda, Ana Claudia C. ;
de Almeida, Erika V. ;
Fuscaldi, Leonardo L. ;
de Barboza, Marycel R. F. F. ;
Malavolta, Luciana .
PHARMACEUTICALS, 2019, 12 (01)
[45]   IODINE-123-MIBG SPECT VERSUS PLANAR IMAGING IN CHILDREN WITH NEURAL CREST TUMORS [J].
GELFAND, MJ ;
ELGAZZAR, AH ;
KRISS, VM ;
MASTERS, PR ;
GOLSCH, GJ .
JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (11) :1753-1757
[46]   Optimisation of quantitative lung SPECT applied to mild COPD: a software phantom simulation study [J].
Pernilla Norberg ;
Anna Olsson ;
Gudrun Alm Carlsson ;
Michael Sandborg ;
Agnetha Gustafsson .
EJNMMI Research, 5
[47]   Optimisation of quantitative lung SPECT applied to mild COPD: a software phantom simulation study [J].
Norberg, Pernilla ;
Olsson, Anna ;
Carlsson, Gudrun Alm ;
Sandborg, Michael ;
Gustafsson, Agnetha .
EJNMMI RESEARCH, 2015, 5 :1-8
[48]   Comparison of Fixed 10 mCi and 15 mCi Iodine-131 Doses for the Treatment of Graves' Disease: 11 Year Study [J].
Dede, Fuat ;
Ones, Tunc ;
Candemir, Sinem ;
Novruzov, Fuad ;
Gungor, Serkan ;
Aras, Mustafa ;
Ozguven, Salih ;
Inanir, Sabahat ;
Erdil, Tanju Yusuf ;
Turoglu, Halil Turgut .
MARMARA MEDICAL JOURNAL, 2011, 24 (01) :26-30
[49]   VALUE OF TL-201 SPECT IMAGING IN CHILDHOOD BRAIN-TUMORS [J].
MARIA, BL ;
DRANE, WE ;
QUISLING, RG ;
RINGDAHL, DM ;
MICKLE, JP ;
MENDENHALL, NP ;
MARCUS, RB ;
MCCOLLOUGH, WM ;
HAMED, LM ;
ESKIN, TA ;
KEDAR, A .
PEDIATRIC NEUROSURGERY, 1994, 20 (01) :11-18
[50]   Real-life radiation burden to relatives of patients treated with iodine-131: a study in eight centres in Flanders (Belgium) [J].
Monsieurs, M ;
Thierens, H ;
Dierckx, RA ;
Casier, K ;
De Baere, E ;
De Ridder, L ;
De Saedeleer, C ;
De Winter, H ;
Lippens, M ;
van Imschoot, S ;
Wulfrank, D ;
Simons, M .