Removal of the intruding Miragel's scleral buckle by pars plana ultrasonic fragmentation

被引:9
作者
Çekiç, O [1 ]
Chang, S [1 ]
Schiff, WM [1 ]
Barile, GR [1 ]
机构
[1] Columbia Univ, Coll Phys & Surg, Dept Ophthalmol, Harkness Eye Inst, New York, NY 10032 USA
关键词
D O I
10.1016/j.ajo.2004.07.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To introduce a surgical approach for removing, intruded scleral buckle resulting from Miragel's implant. DESIGN: Interventional case report. METHODS: After cutting and releasing scleral band externally, a pars plana Fragmatome was used to break up and aspirate pieces of the Miragel's implant that had grown into the eye, filling the vitreous cavity. RESULTS: The intruding Miragel's buckle was Shaved to the plane of the retina without any complication. The retina was completely attached. CONCLUSION: Use of ultrasonic fragmentation by a pars plana approach was effective in removing the intavitreally expanded buckling element without harming the retina. (C) 20105 by Elsevier Inc. All rights reserved.