Recently, concerns have been raised about thermal neutrons causing single event effects in semiconductor devices. For example, if B-10 is present in a semiconductor device, thermal neutron capture reactions can produce several MeV alpha particles. The charge that these alpha particles deposit in a sensitive volume can cause a failure. The number of single event effects from thermal neutrons is the product of the thermal neutron intensity times the thermal neutron failure cross section. This paper presents the status of the thermal neutron flux measurements with the TinMan thermal neutron detector at aircraft altitudes. Thermal neutrons are produced in an airplane when high energy-neutrons, created by the interaction of cosmic rays in the atmosphere, are thermalized in the fuel, the passengers and the airplane itself. Therefore, they are very environment dependent. Airplanes are a particular concern because at aircraft altitudes, the cosmic-ray neutron flux is approximately 300 times the sea-level neutron flux. Therefore, the understanding of the thermal neutron intensity at aircraft altitude is critical for understanding the risks of thermal neutrons to avionics systems. We have designed and built TinMan to measure the thermal neutron environment in prototypical aircraft. The TinMan detector consists of two He-3 ionization chambers. One of the 3He ionization chamber is wrapped in a thin layer of cadmium. Because the cadmium shielding attenuates the thermal neutrons, the difference in count rates between these two detectors reflects the number of thermal neutrons detected. We have calibrated the detector prior to the flight, acquired data during several flights in a NASA ER-2 airplane and plan to fly the detector on other NASA experimental aircrafts, which are more prototypical of a large commercial airplane. This paper will present the status of these measurements.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Development of a High Temperature Neutron Flux Detector
    Shaw, Martin
    Campbell, Bradley
    Ballantine, James
    Roberts, Kevin
    ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2019), 2020, 225
  • [32] THERMAL NEUTRON FLUX DEPRESSION BY ABSORBING FOILS AND FLUX PERTURBATIONS BY THERMAL NEUTRON DETECTORS - REPLY
    RITCHIE, RH
    DALTON, GR
    NUCLEAR SCIENCE AND ENGINEERING, 1961, 11 (04) : 451 - 452
  • [33] Characterization of the hybrid neutron detector
    Singh, M. K.
    Singh, V
    Subrahmanyam, V. S.
    Wong, H. T.
    INDIAN JOURNAL OF PHYSICS, 2019, 93 (02) : 235 - 242
  • [34] Characterization of the hybrid neutron detector
    M. K. Singh
    V. Singh
    V. S. Subrahmanyam
    H. T. Wong
    Indian Journal of Physics, 2019, 93 : 235 - 242
  • [35] Characterization of Thermoluminescent Dosimeters for Neutron Dosimetry at High Altitudes
    D'Avino, Vittoria
    Ambrosino, Fabrizio
    Bedogni, Roberto
    Campoy, Abner Ivan C.
    La Verde, Giuseppe
    Vernetto, Silvia
    Vigorito, Carlo Francesco
    Pugliese, Mariagabriella
    SENSORS, 2022, 22 (15)
  • [36] Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments
    Miller, Marcelo E.
    Sztejnberg, Manuel L.
    Gonzalez, Sara J.
    Thorp, Silvia I.
    Longhino, Juan M.
    Estryk, Guillermo
    MEDICAL PHYSICS, 2011, 38 (12) : 6502 - 6512
  • [37] Thermal neutron flux evaluation by a single crystal CVD diamond detector in LHD deuterium experiment
    Kobayashi, M.
    Ogawa, K.
    Isobe, M.
    Nishitani, T.
    Kamio, S.
    Fujiwara, Y.
    Tsubouchi, T.
    Yoshihashi, S.
    Uritani, A.
    Sakama, M.
    Osakabe, M.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (09):
  • [38] Measurements of Cosmic-Ray Neutron Energy Spectra from Thermal to 15 MeV with Bonner Ball Neutron Detector in Aircraft
    Yajima, Kazuaki
    Yasuda, Hiroshi
    Takada, Masashi
    Sato, Tatsuhiko
    Goka, Tateo
    Matsumoto, Haruhisa
    Nakamura, Takashi
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2010, 47 (01) : 31 - 39
  • [39] Development of a CdTe thermal neutron detector for neutron imaging
    Miyake, Aki
    Nishioka, Takahiro
    Singh, Shailendra
    Morii, Hisashi
    Mimura, Hidenori
    Aoki, Toru
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 677 : 41 - 44
  • [40] Thermal neutron response of neutron detector based on SiC
    Chen, Yu
    Jiang, Yong
    Wu, Jian
    Fan, Xiaoqiang
    Bai, Lixin
    Liu, Bo
    Li, Meng
    Rong, Ru
    Zou, Dehui
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2013, 25 (10): : 2711 - 2716