Effects of abutment screw preload in two implant connection systems: A 3D finite element study

被引:9
|
作者
Jung, Won-kyung [1 ,2 ]
Lee, Won-sup [3 ,4 ]
Kwon, Ho-Beom [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dent Res Inst, 101 Daehak Ro, Seoul 110744, South Korea
[2] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak Ro, Seoul 110744, South Korea
[3] Seoul Natl Univ, Grad Sch Dent, Dept Prosthodont, Seoul, South Korea
[4] Catholic Univ Korea, Dent Hosp, Dept Prosthodont, St Marys Hosp, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
STRESS-DISTRIBUTION; LOADING CONDITIONS; BONE;
D O I
10.1016/j.prosdent.2019.04.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Finite element analysis (FEA) has been used to evaluate the biomechanical behaviors of dental implants. However, in some FEA studies, the influence of the preload condition has been omitted to simplify the analysis. This might affect the results of biomechanical analysis significantly. The preload condition requires analysis. Purpose. The purpose of this FEA study was to evaluate and verify the effects of the presence of the preload condition on abutment screws under the occlusal load for external and internal hexagonal connection systems. Material and method. The finite element models consisting of bone blocks, 2 different implant systems (Osstem US and GS system; Osstem Implant Co), and crowns were created. With these components, a total of 6 models with different conditions were constructed for FEA: external hexagonal connection system only with preload (E0), external hexagonal connection system with no preload but occlusal load (EN), external hexagonal system with both preload and occlusal load (EP), internal hexagonal system only with preload (10), internal hexagonal system with no preload but occlusal load (IN), and internal hexagonal system with both preload and occlusal load (IP). An 113-degree oblique load (100 N) to the axis of the implant was applied on the occlusal surface of the crown for the models with occlusal load. A preload of 825 N was applied in the abutment screw of the models EO, EP, IO, and IP. The maximum von Mises stress, maximum principal stress, and maximum displacement of the components of the models were evaluated. Results. Both external and internal connection systems resulted in higher maximum von Mises stress and maximum principal stress values in the presence of preload in the abutment screw. The internal connection system showed higher displacement values than the external system with or without occlusal loading, and values tended to increase with the preload condition. Conclusion. The presence of a preload condition significantly affected the biomechanical behaviors of the components of 2 different connection systems. The preload condition should be included in FEA to achieve more realistic results.
引用
收藏
页码:474.e1 / 474.e8
页数:8
相关论文
共 50 条
  • [31] Comparison of three implant systems under preload loss: A finite element analysis validated by digital image correlation methods
    Anniwaer, Annikaer
    Yin, Zhengrong
    Zhu, Jiakang
    Jin, Chunxiao
    Muhetaer, Aihemaiti
    Huang, Cui
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024, : 285 - 293
  • [32] Mechanical effect of taper position in abutment hole and screw taper angles on implant system and peri-implant tissue: a finite element analysis
    Hou, Hu
    Zhang, Jianguo
    Huang, Song
    Hu, Fengling
    Yu, Youcheng
    Song, Liang
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [33] The Effects of Loading on the Preload and Dimensions of the Abutment Screw for a 3-Unit Cantilever-Fixed Prosthesis Design
    Setia, Gaurav
    Yousef, Hoda
    Ehrenberg, David
    Luke, Allyn
    Weiner, Saul
    IMPLANT DENTISTRY, 2013, 22 (04) : 414 - 421
  • [34] Mechanical Evaluation of an Implant-Abutment Self-Locking Taper Connection: Finite Element Analysis and Experimental Tests
    Sannino, Gianpaolo
    Barlattani, Alberto
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : E17 - E26
  • [35] Biomechanical analysis of rigid and non-rigid connection with implant abutment designs for tooth-implant supported prosthesis: A finite element analysis
    Huang, Yen-Chang
    Ding, Shinn-Jyh
    Yuan, Cadmus
    Yan, Min
    JOURNAL OF DENTAL SCIENCES, 2022, 17 (01) : 490 - 499
  • [36] Effect of Marginal Bone Integrity and Aftermarket Abutment Screws on Dental Implant Systems-A Preliminary Study with Finite Element Method
    Wu, Yu-Ling
    Tsai, Ming-Hsu
    Chen, Hung-Shyong
    Lin, Ching-Ping
    Wu, Aaron Yu-Jen
    MATERIALS, 2022, 15 (17)
  • [37] Influence of parafunctional loading and prosthetic connection on stress distribution: A 3D finite element analysis
    Torcato, Leonardo Bueno
    Pellizzer, Eduardo Piza
    Verri, Fellippo Ramos
    Falcon-Antenucci, Rosse Mary
    Santiago Junior, Joel Ferreira
    de Faria Almeida, Daniel Augusto
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (05) : 644 - 651
  • [38] Biomechanics of internal connection in mandibular implant-supported prosthesis under effect of loadings and number of implants: A 3D finite element analysis
    Dayrell, Andreza Costa
    Pimenta de Araujo, Cintia Tereza
    Rocha, Ricardo Lopes
    Isolan, Cristina Pereira
    Noritomi, Pedro Yoshito
    Mesquita, Marcelo Ferraz
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 148
  • [39] Finite Element Analysis of the Effect of Tightening Torque on the Connection Stability of a Two-Piece Zirconia Implant System
    Choi, Hyunsuk
    Hong, Min-Ho
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2022, 2022
  • [40] Evaluation of postoperative dental implant primary stability using 3D finite element analysis
    Pammer, David
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (03) : 280 - 287