Effects of abutment screw preload in two implant connection systems: A 3D finite element study

被引:9
|
作者
Jung, Won-kyung [1 ,2 ]
Lee, Won-sup [3 ,4 ]
Kwon, Ho-Beom [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dent Res Inst, 101 Daehak Ro, Seoul 110744, South Korea
[2] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak Ro, Seoul 110744, South Korea
[3] Seoul Natl Univ, Grad Sch Dent, Dept Prosthodont, Seoul, South Korea
[4] Catholic Univ Korea, Dent Hosp, Dept Prosthodont, St Marys Hosp, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
STRESS-DISTRIBUTION; LOADING CONDITIONS; BONE;
D O I
10.1016/j.prosdent.2019.04.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Finite element analysis (FEA) has been used to evaluate the biomechanical behaviors of dental implants. However, in some FEA studies, the influence of the preload condition has been omitted to simplify the analysis. This might affect the results of biomechanical analysis significantly. The preload condition requires analysis. Purpose. The purpose of this FEA study was to evaluate and verify the effects of the presence of the preload condition on abutment screws under the occlusal load for external and internal hexagonal connection systems. Material and method. The finite element models consisting of bone blocks, 2 different implant systems (Osstem US and GS system; Osstem Implant Co), and crowns were created. With these components, a total of 6 models with different conditions were constructed for FEA: external hexagonal connection system only with preload (E0), external hexagonal connection system with no preload but occlusal load (EN), external hexagonal system with both preload and occlusal load (EP), internal hexagonal system only with preload (10), internal hexagonal system with no preload but occlusal load (IN), and internal hexagonal system with both preload and occlusal load (IP). An 113-degree oblique load (100 N) to the axis of the implant was applied on the occlusal surface of the crown for the models with occlusal load. A preload of 825 N was applied in the abutment screw of the models EO, EP, IO, and IP. The maximum von Mises stress, maximum principal stress, and maximum displacement of the components of the models were evaluated. Results. Both external and internal connection systems resulted in higher maximum von Mises stress and maximum principal stress values in the presence of preload in the abutment screw. The internal connection system showed higher displacement values than the external system with or without occlusal loading, and values tended to increase with the preload condition. Conclusion. The presence of a preload condition significantly affected the biomechanical behaviors of the components of 2 different connection systems. The preload condition should be included in FEA to achieve more realistic results.
引用
收藏
页码:474.e1 / 474.e8
页数:8
相关论文
共 50 条
  • [21] Comparative Evaluation of Three Abutment-Implant Interfaces on Stress Distribution in and Around Different Implant Systems: A Finite Element Analysis
    Kharsan, Vishwas
    Bandgar, Vaibhav
    Mirza, Aftab
    Jagtiani, Kiran
    Dhariwal, Neha
    Kore, Rahul
    CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (04) : 590 - 594
  • [22] A SENSITIVITY STUDY BY FINITE ELEMENT ANALYSIS FOR THE ABUTMENT-IMPLANT-BONE SYSTEM
    Muraev, A. A.
    Tatoyan, A. D.
    Dolgalev, A. A.
    Vershinin, A. V.
    Yakovlev, M. Ya.
    Ivanov, S. Yu
    Konovalov, D. A.
    Petrovsky, K. A.
    Levin, V. A.
    MATHEMATICS AND MECHANICS OF COMPLEX SYSTEMS, 2022, 10 (01) : 1 - 20
  • [23] Crestal and Subcrestal Placement of Morse Cone Implant-Abutment Connection Implants: An In Vitro Finite Element Analysis (FEA) Study
    Comuzzi, Luca
    Ceddia, Mario
    Di Pietro, Natalia
    Inchingolo, Francesco
    Inchingolo, Angelo Michele
    Romasco, Tea
    Tumedei, Margherita
    Specchiulli, Alessandro
    Piattelli, Adriano
    Trentadue, Bartolomeo
    BIOMEDICINES, 2023, 11 (11)
  • [24] Biomechanical Effects of Ti-Base Abutment Height on the Dental Implant System: A Finite Element Analysis
    Beltran-Guijarro, Miguel
    Perez-Pevida, Esteban
    Chavarri-Prado, David
    Estrada-Martinez, Alejandro
    Dieguez-Pereira, Markel
    Sanchez-Lasheras, Fernando
    Brizuela-Velasco, Aritza
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (04)
  • [25] A Comparative 3D Finite Element Computational Study of Three Connections
    Farronato, Davide
    Manfredini, Mattia
    Stevanello, Andrea
    Campana, Veronica
    Azzi, Lorenzo
    Farronato, Marco
    MATERIALS, 2019, 12 (19)
  • [26] How do implant threads and diameters affect the all-on-four success? A 3D finite element analysis study
    Zor, Zeynep Fatma
    Kilinc, Yeliz
    Erkmen, Erkan
    Kurt, Ahmet
    TECHNOLOGY AND HEALTH CARE, 2022, 30 (05) : 1031 - 1042
  • [27] Effect of Different Implant-Abutment Mismatches on Stress Distribution: A 3-Dimensional Finite Element Study
    Esfahanian, Vahid
    Khosravi, Armin
    Ketabi, Mohammad
    Deporter, Douglas
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (05) : 370 - 374
  • [28] Can the modeling for simplification of a dental implant surface affect the accuracy of 3D finite element analysis?
    Verri, Fellippo Ramos
    Cruz, Ronaldo Silva
    de Souza Batista, Victor Eduardo
    de Faria Almeida, Daniel Augusto
    Goncales Verri, Ana Caroline
    de Araujo Lemos, Cleidiel Aparecido
    Santiago Junior, Joel Ferreira
    Pellizzer, Eduardo Piza
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (15) : 1665 - 1672
  • [29] Characteristics of implant-CAD/CAM abutment connections of two different internal connection systems
    Sumi, T.
    Braian, M.
    Shimada, A.
    Shibata, N.
    Takeshita, K.
    Vandeweghe, S.
    Coelho, P. G.
    Wennerberg, A.
    Jimbo, R.
    JOURNAL OF ORAL REHABILITATION, 2012, 39 (05): : 391 - 398
  • [30] Effects of the Screw-Access Hole Diameter on the Biomechanical Behaviors of 4 Types of Cement-Retained Implant Prosthodontic Systems and Their Surrounding Cortical Bones: A 3D Finite Element Analysis
    Du, Liangzhi
    Li, Zhe
    Chang, Xiaofeng
    Rahhal, Omar
    Qin, Bowen
    Wen, Xi
    Zhou, Dangxia
    IMPLANT DENTISTRY, 2018, 27 (05) : 555 - 563