Effects of abutment screw preload in two implant connection systems: A 3D finite element study

被引:9
|
作者
Jung, Won-kyung [1 ,2 ]
Lee, Won-sup [3 ,4 ]
Kwon, Ho-Beom [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dent Res Inst, 101 Daehak Ro, Seoul 110744, South Korea
[2] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak Ro, Seoul 110744, South Korea
[3] Seoul Natl Univ, Grad Sch Dent, Dept Prosthodont, Seoul, South Korea
[4] Catholic Univ Korea, Dent Hosp, Dept Prosthodont, St Marys Hosp, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
STRESS-DISTRIBUTION; LOADING CONDITIONS; BONE;
D O I
10.1016/j.prosdent.2019.04.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Finite element analysis (FEA) has been used to evaluate the biomechanical behaviors of dental implants. However, in some FEA studies, the influence of the preload condition has been omitted to simplify the analysis. This might affect the results of biomechanical analysis significantly. The preload condition requires analysis. Purpose. The purpose of this FEA study was to evaluate and verify the effects of the presence of the preload condition on abutment screws under the occlusal load for external and internal hexagonal connection systems. Material and method. The finite element models consisting of bone blocks, 2 different implant systems (Osstem US and GS system; Osstem Implant Co), and crowns were created. With these components, a total of 6 models with different conditions were constructed for FEA: external hexagonal connection system only with preload (E0), external hexagonal connection system with no preload but occlusal load (EN), external hexagonal system with both preload and occlusal load (EP), internal hexagonal system only with preload (10), internal hexagonal system with no preload but occlusal load (IN), and internal hexagonal system with both preload and occlusal load (IP). An 113-degree oblique load (100 N) to the axis of the implant was applied on the occlusal surface of the crown for the models with occlusal load. A preload of 825 N was applied in the abutment screw of the models EO, EP, IO, and IP. The maximum von Mises stress, maximum principal stress, and maximum displacement of the components of the models were evaluated. Results. Both external and internal connection systems resulted in higher maximum von Mises stress and maximum principal stress values in the presence of preload in the abutment screw. The internal connection system showed higher displacement values than the external system with or without occlusal loading, and values tended to increase with the preload condition. Conclusion. The presence of a preload condition significantly affected the biomechanical behaviors of the components of 2 different connection systems. The preload condition should be included in FEA to achieve more realistic results.
引用
收藏
页码:474.e1 / 474.e8
页数:8
相关论文
共 50 条
  • [1] Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws
    Zipprich, Holger
    Rathe, Florian
    Pinz, Soeren
    Schlotmann, Luca
    Lauer, Hans-Christoph
    Ratka, Christoph
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : E25 - E32
  • [2] The effect of abutment material stiffness on the mechanical behavior of dental implant assemblies: A 3D finite element study
    Tonin, Bruna S. H.
    Fu, Jing
    He, Yiting
    Ye, Ning
    Chew, Hooi Pin
    Fok, Alex
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 142
  • [3] Effects of Marginal Bone Loss Progression on Stress Distribution in Different Implant-Abutment Connections and Abutment Materials: A 3D Finite Element Analysis Study
    Lin, Ching-Ping
    Shyu, Yi-Ting
    Wu, Yu-Ling
    Tsai, Ming-Hsu
    Chen, Hung-Shyong
    Wu, Aaron Yu-Jen
    MATERIALS, 2022, 15 (17)
  • [4] Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element Study
    Ferreira Koyama Takahashi, Jessica Mie
    Dayrell, Andreza Costa
    Xediek Consani, Rafael Leonardo
    de Arruda Nobilo, Mauro Antonio
    Pessanha Henriques, Guilherme Elias
    Mesquita, Marcelo Ferraz
    Journal of Oral Implantology, 2015, 41 (02) : 133 - 137
  • [5] Effects of implant diameter, implant-abutment connection type, and bone density on the biomechanical stability of implant components and bone: A finite element analysis study
    Lee, Hyeonjong
    Jo, Minhye
    Sailer, Irena
    Noh, Gunwoo
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04) : 716 - 728
  • [6] Different Conical Angle Connection of Implant and Abutment Behavior: A Static and Dynamic Load Test and Finite Element Analysis Study
    Kortvelyessy, Gyozo
    Szabo, Arpad Laszlo
    Pelsoczi-Kovacs, Istvan
    Tarjanyi, Tamas
    Toth, Zsolt
    Karpati, Krisztina
    Matusovits, Danica
    Hangyasi, Botond David
    Barath, Zoltan
    MATERIALS, 2023, 16 (05)
  • [7] Effects of diameters of implant and abutment screw on stress distribution within dental implant and alveolar bone: A threedimensional finite element analysis
    Shen, Yen -Wen
    Huang, Heng-Li
    Hsu, Jui-Ting
    Fuh, Lih-Jyh
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (02) : 1126 - 1134
  • [8] Stress Analysis in Anterior Single Unit Implant with Different Abutment Connection Designs: A Finite Element Study
    Kumma, Pattamapom
    Sareekuea, Patcharee
    Iadnagkhan, Panupong
    Puengpaiboon, Usanee
    Rattanapan, Nichapat
    Kunarak, Piriya
    Sukjamsri, Chamaipom
    2023 7TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND APPLICATIONS, ICBEA, 2023, : 93 - 97
  • [9] The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis
    Oğuz Eraslan
    Özgür İnan
    Clinical Oral Investigations, 2010, 14 : 411 - 416
  • [10] The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis
    Eraslan, Oguz
    Inan, Oezguer
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) : 411 - 416