Correction of Proton Resonance Frequency Shift MR-Thermometry Errors Caused by Heat-Induced Magnetic Susceptibility Changes during High Intensity Focused Ultrasound Ablations in Tissues Containing Fat

被引:27
作者
Baron, Paul [1 ]
Deckers, Roel [1 ]
de Greef, Martijn [1 ]
Merckel, Laura G. [1 ]
Bakker, Chris J. G. [1 ]
Bouwman, Job G. [1 ]
Bleys, Ronald L. A. W. [1 ]
van den Bosch, Maurice A. A. J. [1 ]
Bartels, Lambertus W. [1 ]
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
关键词
magnetic susceptibility; temperature; PRFS-based MR thermometry; MR-HIFU; breast tissue; CHEMICAL-SHIFT; BREAST-CANCER; TEMPERATURE; FIELD; DEPENDENCE; EFFICIENT;
D O I
10.1002/mrm.25063
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeIn this study, we aim to demonstrate the sensitivity of proton resonance frequency shift (PRFS) -based thermometry to heat-induced magnetic susceptibility changes and to present and evaluate a model-based correction procedure. Theory and MethodsTo demonstrate the expected temperature effect, field disturbances during high intensity focused ultrasound sonications were monitored in breast fat samples with a three-dimensional (3D) gradient echo sequence. To evaluate the correction procedure, the interface of tissue-mimicking ethylene glycol gel and fat was sonicated. During sonication, the temperature was monitored with a 2D dual flip angle multi-echo gradient echo sequence, allowing for PRFS-based relative and referenced temperature measurements in the gel and T-1-based temperature measurements in fat. The PRFS-based measurement in the gel was corrected by minimizing the discrepancy between the observed 2D temperature profile and the profile predicted by a 3D thermal model. ResultsThe HIFU sonications of breast fat resulted in a magnetic field disturbance which completely disappeared after cooling. For the correction method, the 5th to 95th percentile interval of the PRFS-thermometry error in the gel decreased from 3.8 degrees C before correction to 2.0-2.3 degrees C after correction. ConclusionThis study has shown the effects of magnetic susceptibility changes induced by heating of breast fatty tissue samples. The resultant errors can be reduced by the use of a model-based correction procedure. Magn Reson Med 72:1580-1589, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1580 / 1589
页数:10
相关论文
共 35 条
  • [1] BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
  • [2] Alias subtraction more efficient than conventional zero-padding in the Fourier-based calculation of the susceptibility induced perturbation of the magnetic field in MR
    Bouwman, Job G.
    Bakker, Chris J. G.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (02) : 621 - 630
  • [3] Statement of the science concerning locoregional treatments after preoperative chemotherapy for breast cancer: A National Cancer Institute conference
    Buchholz, Thomas A.
    Lehman, Constance D.
    Harris, Jay R.
    Pockaj, Barbara A.
    Khouri, Nagi
    Hylton, Nola F.
    Miller, Michael J.
    Whelan, Timothy
    Pierce, Lori J.
    Esserman, Laura J.
    Newman, Lisa A.
    Smith, Barbara L.
    Bear, Harry D.
    Mamounas, Eleftherios P.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2008, 26 (05) : 791 - 797
  • [4] Thermal ablation of uterine fibroids using MR-guided focused ultrasound-a truly non-invasive treatment modality
    Chapman, Alexander
    ter Haar, Gail
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (10) : 2505 - 2511
  • [5] MR TEMPERATURE MAPPING OF FOCUSED ULTRASOUND SURGERY
    CLINE, HE
    HYNYNEN, K
    HARDY, CJ
    WATKINS, RD
    SCHENCK, JF
    JOLESZ, FA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) : 628 - 636
  • [6] RLSQ - T1, T2, AND RHO-CALCULATIONS, COMBINING RATIOS AND LEAST-SQUARES
    DENKLEEF, JJEI
    CUPPEN, JJM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (06) : 513 - 524
  • [7] Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
    Deoni, SCL
    Rutt, BK
    Peters, TM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) : 515 - 526
  • [8] DEPOORTER J, 1995, MAGN RESON MED, V34, P359, DOI 10.1002/mrm.1910340313
  • [9] EXACT-SOLUTIONS TO THE MULTIREGION TIME-DEPENDENT BIOHEAT EQUATION .1. SOLUTION DEVELOPMENT
    DURKEE, JW
    ANTICH, PP
    LEE, CE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (07) : 847 - 867
  • [10] Simultaneous T1 measurements and proton resonance frequency shift based thermometry using variable flip angles
    Hey, S.
    de Smet, M.
    Stehning, C.
    Grull, H.
    Keupp, J.
    Moonen, C. T. W.
    Ries, M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 457 - 463