Generation of non-Gaussian stationary random excitations with specified cross-power spectral densities using zero memory non-linear transformation for fatigue test purposes

被引:5
作者
Cui, Song [1 ]
Zheng, Enlai [2 ]
机构
[1] Nanjing Inst Technol, Sch Automobile & Rail Transit, Nanjing, Peoples R China
[2] Nanjing Agr Univ, Dept Mech Engn, Nanjing, Peoples R China
关键词
Zero-memory non-linear methods; Super-Gaussian random excitations; Magnitude distortion; Cross-power spectral density; FIR filter; CONTROL ALGORITHM; VIBRATION;
D O I
10.1016/j.ymssp.2020.107535
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Zero-memory non-linear (ZMNL) methods have long been a type of very useful tools in creating super-Gaussian random excitations for fatigue test. The major drawback of this method is that the magnitude distortion can be seen in both auto-power spectral density (ASD) and cross power-spectral density (CSD) of the excitation if the dynamic range of the target power spectral density (PSD) is large. To study the problem, we introduced Fourier series of a Gaussian signal into a cubic system, which is a common mathematical model shared by most of the ZMNL functions. We found that the cubic system produces a component leading to the distortion of both ASD and CSD. Meanwhile, if the shape of the reference ASD is flat in a frequency band, the distortion will not happen in the band. Based on this findings, a novel method is proposed in this article. It employs a pseudo reference PSD with flat ASDs to generate non-Gaussian signals in order to avoid the PSD distortions. Designed FIR filters are then applied to rescale the ASDs of the generated signals. After, iterative processes are introduced to recover the kurtoses of these filtered signals. The method is applied on a two-input and two-output numerical model, the feasibility and the availability of the method is verified. Finally, two control schemes based on the proposed pseudo reference PSD method are provided for a shaker table test. Test results show that both control schemes can eliminate the mismatch between the target PSD and the measured PSD of a shaker table. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:23
相关论文
共 26 条
[1]   Cycle distribution and fatigue damage assessment in broad-band non-Gaussian random processes [J].
Benasciutti, D ;
Tovo, R .
PROBABILISTIC ENGINEERING MECHANICS, 2005, 20 (02) :115-127
[2]  
Benasciutti D, 2018, MATERIALWISS WERKST, V49, P345, DOI 10.1002/mawe.201700190
[3]  
Bendat J.S., 1998, NONLINEAR SYSTEM TEC
[4]  
Bendat J. S., 2000, RANDOM DATA ANAL MEA
[5]   The effort of the dynamic simulation on the fatigue damage evaluation of flexible mechanical systems loaded by non-Gaussian and non stationary loads [J].
Cianetti, F. ;
Palmieri, M. ;
Slavic, J. ;
Braccesi, C. ;
Morettini, G. .
INTERNATIONAL JOURNAL OF FATIGUE, 2017, 103 :60-72
[6]  
Cui S., 2020, COMPOS SCI TECHNOL
[7]   Control algorithm update for multi-input multi-output random environment test [J].
Cui, Song ;
Chen, Huaihai ;
He, Xudong ;
Zheng, Wei .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2018, 111 :643-662
[8]   Time-domain approach for multi-exciter random environment test [J].
Cui, Song ;
Chen, Huai-hai ;
He, Xu-dong .
JOURNAL OF SOUND AND VIBRATION, 2017, 398 :52-69
[9]   Matrix Power Control Algorithm for Multi-input Multi-output Random Vibration Test [J].
Cui Xuli ;
Chen Huaihai ;
He Xudong ;
Jiang Shuangyan .
CHINESE JOURNAL OF AERONAUTICS, 2011, 24 (06) :741-748
[10]  
Dewell L., 2002, APPL MECH REV, V55