Extending the throughput of Biacore 4000 biosensor to accelerate kinetic analysis of antibody-antigen interaction
被引:16
|
作者:
Kamat, Vishal
论文数: 0引用数: 0
h-index: 0
机构:
Regeneron Pharmaceut, Therapeut Prot, Biomol HTS Ctr, 777 Old Saw Mill River Rd, Tarrytown, NY 10591 USARegeneron Pharmaceut, Therapeut Prot, Biomol HTS Ctr, 777 Old Saw Mill River Rd, Tarrytown, NY 10591 USA
Kamat, Vishal
[1
]
Rafique, Ashique
论文数: 0引用数: 0
h-index: 0
机构:
Regeneron Pharmaceut, Therapeut Prot, Biomol HTS Ctr, 777 Old Saw Mill River Rd, Tarrytown, NY 10591 USARegeneron Pharmaceut, Therapeut Prot, Biomol HTS Ctr, 777 Old Saw Mill River Rd, Tarrytown, NY 10591 USA
Rafique, Ashique
[1
]
机构:
[1] Regeneron Pharmaceut, Therapeut Prot, Biomol HTS Ctr, 777 Old Saw Mill River Rd, Tarrytown, NY 10591 USA
The surface plasmon resonance (SPR) biosensors are being routinely used in different stages of drug discovery and development. However, the lack of high throughput SPR biosensors continues to be a primary bottleneck for the rapid kinetic screening of large panels of monoclonal antibodies (mAbs). To further increase the throughput of the Biacore 4000 biosensor, we have developed three kinetic screening assays to characterize mAb-antigen interactions (i) 16-mAb capture kinetic, (ii) single cycle kinetic (SCK), and (iii) parallel kinetic (PK). The performance of all three kinetic assays was evaluated by characterizing the binding of kinetically diverse human mAbs to four antigens with molecular weights of 1410, 29kD, 38kD, and 48kD and binding affinities ranging from 130pM to 200 nM. The binding rate constants measured using all three kinetic assays were reproducible across multiple experiments and correlated with the values generated using the conventional 8-mAb capture kinetic assay on the Biacore 4000 (R-2 > 0.94). Moreover, the 16-mAb capture assay decreased experiment time and analyte consumption by 35% and 50%, respectively. This work illustrates the significance of the 16-mAb capture kinetic, SCK, and PK assays to increase the throughput of Biacore 4000 and to support rapid kinetic screening of mAbs. (C) 2017 The Authors. Published by Elsevier Inc.
机构:
Jiangnan Univ, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
Jiangnan Univ, Sch Food Sci & Technol, Int Joint Res Lab Biointerface & Biodetect, Wuxi 214122, Jiangsu, Peoples R ChinaJiangnan Univ, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
Li, Yue
Liu, Liqiang
论文数: 0引用数: 0
h-index: 0
机构:
Jiangnan Univ, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
Jiangnan Univ, Sch Food Sci & Technol, Int Joint Res Lab Biointerface & Biodetect, Wuxi 214122, Jiangsu, Peoples R ChinaJiangnan Univ, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
Liu, Liqiang
Xu, Chuanlai
论文数: 0引用数: 0
h-index: 0
机构:
Jiangnan Univ, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
Jiangnan Univ, Sch Food Sci & Technol, Int Joint Res Lab Biointerface & Biodetect, Wuxi 214122, Jiangsu, Peoples R ChinaJiangnan Univ, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
Xu, Chuanlai
Kuang, Hua
论文数: 0引用数: 0
h-index: 0
机构:
Jiangnan Univ, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
Jiangnan Univ, Sch Food Sci & Technol, Int Joint Res Lab Biointerface & Biodetect, Wuxi 214122, Jiangsu, Peoples R ChinaJiangnan Univ, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
Kuang, Hua
Sun, Li
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Inspect & Quarantine, Beijing 100176, Peoples R ChinaJiangnan Univ, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China