Extending the throughput of Biacore 4000 biosensor to accelerate kinetic analysis of antibody-antigen interaction

被引:16
作者
Kamat, Vishal [1 ]
Rafique, Ashique [1 ]
机构
[1] Regeneron Pharmaceut, Therapeut Prot, Biomol HTS Ctr, 777 Old Saw Mill River Rd, Tarrytown, NY 10591 USA
关键词
Biacore; Surface plasmon resonance; Label-free optical biosensor; Monoclonal antibody; High throughput; Antibody-antigen interaction; Binding kinetic; Affinity; A100;
D O I
10.1016/j.ab.2017.04.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The surface plasmon resonance (SPR) biosensors are being routinely used in different stages of drug discovery and development. However, the lack of high throughput SPR biosensors continues to be a primary bottleneck for the rapid kinetic screening of large panels of monoclonal antibodies (mAbs). To further increase the throughput of the Biacore 4000 biosensor, we have developed three kinetic screening assays to characterize mAb-antigen interactions (i) 16-mAb capture kinetic, (ii) single cycle kinetic (SCK), and (iii) parallel kinetic (PK). The performance of all three kinetic assays was evaluated by characterizing the binding of kinetically diverse human mAbs to four antigens with molecular weights of 1410, 29kD, 38kD, and 48kD and binding affinities ranging from 130pM to 200 nM. The binding rate constants measured using all three kinetic assays were reproducible across multiple experiments and correlated with the values generated using the conventional 8-mAb capture kinetic assay on the Biacore 4000 (R-2 > 0.94). Moreover, the 16-mAb capture assay decreased experiment time and analyte consumption by 35% and 50%, respectively. This work illustrates the significance of the 16-mAb capture kinetic, SCK, and PK assays to increase the throughput of Biacore 4000 and to support rapid kinetic screening of mAbs. (C) 2017 The Authors. Published by Elsevier Inc.
引用
收藏
页码:75 / 86
页数:12
相关论文
共 13 条
[1]   Expanding the ProteOn XPR36 biosensor into a 36-ligand array protein interaction analysis [J].
Abdiche, Yasmina N. ;
Lindquist, Kevin C. ;
Pinkerton, Alanna ;
Pons, Jaume ;
Rajpal, Arvind .
ANALYTICAL BIOCHEMISTRY, 2011, 411 (01) :139-151
[2]   Exploring "one-shot" kinetics and small molecule analysis using the ProteOn XPR36 array biosensor [J].
Bravman, Tsafrir ;
Bronner, Vered ;
Lavie, Kobi ;
Notcovich, Ariel ;
Papalia, Giuseppe A. ;
Myszka, David G. .
ANALYTICAL BIOCHEMISTRY, 2006, 358 (02) :281-288
[3]   Kinetic screening of antibodies from crude hybridoma samples using Biacore [J].
Canziani, GA ;
Klakamp, S ;
Myszka, DG .
ANALYTICAL BIOCHEMISTRY, 2004, 325 (02) :301-307
[4]  
Davidoff SN, 2015, Label-Free Biosens Methods Drug Discov, P35
[5]  
Hearty Stephen, 2012, Methods Mol Biol, V907, P411, DOI 10.1007/978-1-61779-974-7_24
[6]   Exploring sensitivity & throughput of a parallel flow SPRi biosensor for characterization of antibody-antigen interaction [J].
Kamat, Vishal ;
Rafique, Ashique .
ANALYTICAL BIOCHEMISTRY, 2017, 525 :8-22
[7]   Analyzing a kinetic titration series using affinity biosensors [J].
Karlsson, R ;
Katsamba, PS ;
Nordin, H ;
Pol, E ;
Myszka, DG .
ANALYTICAL BIOCHEMISTRY, 2006, 349 (01) :136-147
[8]   SPR Imaging for High Throughput, Label-Free Interaction Analysis [J].
Lausted, Christopher ;
Hu, Zhiyuan ;
Hood, Leroy ;
Campbell, Charles T. .
COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2009, 12 (08) :741-751
[9]   High throughput ranking of recombinant avian scFv antibody fragments from crude lysates using the Biacore A100 [J].
Leonard, Paul ;
Safsten, Par ;
Hearty, Stephen ;
McDonnell, Barry ;
Finlay, William ;
O'Kennedy, Richard .
JOURNAL OF IMMUNOLOGICAL METHODS, 2007, 323 (02) :172-179
[10]  
Liu Y., 2014, FORTEBIO INTERACT, V7, P7