Renewable sol-gel carbon ceramic electrodes modified with a Ru-complex for the amperometric detection of L-cysteine and glutathione

被引:138
作者
Salimi, A [1 ]
Pourbeyram, S [1 ]
机构
[1] Kurdistan Univ, Fac Sci, Dept Chem, Sanandaj, Iran
关键词
modified electrode; carbon ceramic composite electrode; L-cysteine; glutathione; electrocatalytic oxidation; sol; -gel; ruthenium complex;
D O I
10.1016/S0039-9140(03)00125-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A renewable three-dimensional chemically modified carbon ceramic electrode containing Ru [(tpy)(bpy)Cl] PF6 was constructed by sol-gel technique. It exhibits an excellent electro-catalytic activity for oxidation Of L-cysteine and glutathione at pH range 2-8. Cyclic voltammetry was employed to characterize the electrochemical behavior of the. chemically modified electrode. The electrocatalytic behavior is further exploited as a sensitive detection scheme for L-cysteine and glutathione by hydrodynamic amperometry. Optimum pH value for detection is 2 for both L-cysteine and glutathione. The catalytic rate constants for L-cysteine and glutathione were determined, which were about 2.1 x 10(3) and 2.5 x 103 M-1 s(-1), respectively. Under the optimized condition the calibration curves are linear in the concentration range 5-685 and 5-700 muM for L-cysteine and glutathione determination, respectively. The detection limit (SIN = 3) and sensitivity is 1 muM, 5 nA/muM for L-cysteine and 1 muM, 7.8 - nA/muM for glutathione. The relative standard deviation (RSD) for the amperogram's currents with five injections of L-cysteine or glutathione at concentration range of linear calibration is < 1.5%. The advantages of this amperometric detector are: high sensitivity, good catalytic effect, short response time (t < 3 s), remarkable long-term stability, simplicity of preparation and reproducibility of surface fouling (RSD for six successive polishing is 3.31%). This sensor can be used as a chromatographic detector for analysis of L-cysteine and glutathione. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:205 / 214
页数:10
相关论文
共 37 条
[1]  
ANDRIEUX CP, 1978, J ELECTROANAL CHEM, V93, P163, DOI 10.1016/S0022-0728(78)80230-7
[2]   ACETAMINOPHEN HEPATOTOXICITY [J].
BLACK, M .
ANNUAL REVIEW OF MEDICINE, 1984, 35 :577-593
[3]   The electrocatalytic reactions of cysteine and cystine by water-soluble iron porphyrin, manganese porphyrin and iron(II) phenanthrolines [J].
Chen, SM .
ELECTROCHIMICA ACTA, 1997, 42 (11) :1663-1673
[4]   Determination of cysteine in human plasma by high-performance liquid chromatography and ultraviolet detection after pre-column derivatization with 2-chloro-1-methylpyridinium iodide [J].
Chwatko, G ;
Bald, E .
TALANTA, 2000, 52 (03) :509-515
[5]   FLOW-INJECTION AMPEROMETRY OF CYSTEINE AND GLUTATHIONE AT AN ELECTRODE MODIFIED WITH A RUTHENIUM-CONTAINING INORGANIC FILM [J].
COX, JA ;
GRAY, TJ .
ELECTROANALYSIS, 1990, 2 (02) :107-111
[6]   Electrocatalytic and analytical responses of 10-methylphenothiazine toward reduced glutathione [J].
Gong, X ;
Li, HL .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (01) :238-241
[7]   OXIDATION OF HYDRAZINE ON PLATINUM IN ACID SOLUTION [J].
HARRISON, JA ;
KHAN, ZA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1970, 28 (01) :131-&
[8]  
How W., 1991, J ELECTROANAL CHEM, V316, P155
[9]   Determination of thiols by capillary electrophoresis with amperometric detection at a coenzyme pyrroloquinoline quinone modified electrode [J].
Inoue, T ;
Kirchhoff, JR .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1349-1354
[10]   Electrochemical detection of thiols with a coenzyme pyrroloquinoline quinone modified electrode [J].
Inoue, T ;
Kirchhoff, JR .
ANALYTICAL CHEMISTRY, 2000, 72 (23) :5755-5760