Validation of a computational knee joint model using an alignment method for the knee laxity test and computed tomography

被引:13
作者
Kang, Kyoung-Tak [1 ]
Kim, Sung-Hwan [2 ]
Son, Juhyun [1 ]
Lee, Young Han [3 ,4 ]
Koh, Yong-Gon [5 ]
机构
[1] Yonsei Univ, Dept Mech Engn, 50 Yonsei Ro, Seoul 03722, South Korea
[2] Yonsei Univ, Coll Med, Arthroscopy & Joint Res Inst, Dept Orthoped Surg,Gangnam Severance Hosp, 211 Eonju Ro, Seoul 06273, South Korea
[3] Yonsei Univ, Coll Med, Med Convergence Res Inst, Dept Radiol,Res Inst Radiol Sci, 50-1 Yonsei Ro, Seoul 03722, South Korea
[4] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, 50-1 Yonsei Ro, Seoul 03722, South Korea
[5] Yonsei Sarang Hosp, Dept Orthopaed Surg, Joint Reconstruct Ctr, 50 Yonsei Ro, Seoul 06698, South Korea
关键词
3D imaging; computed tomography; computer simulation; knee joint; laxity test; CRUCIATE LIGAMENT RECONSTRUCTION; MEDIAL COLLATERAL LIGAMENT; FINITE-ELEMENT MODEL; MENISCAL ATTACHMENTS; ARTICULAR-CARTILAGE; COMPLETE TEARS; BIOMECHANICS; SENSITIVITY; GEOMETRY; BEHAVIOR;
D O I
10.3233/BME-171686
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BACKGROUND: Computational models have been identified as efficient techniques in the clinical decision-making process. However, computational model was validated using published data in most previous studies, and the kinematic validation of such models still remains a challenge. Recently, studies using medical imaging have provided a more accurate visualization of knee joint kinematics. OBJECTIVE: The purpose of the present study was to perform kinematic validation for the subject-specific computational knee joint model by comparison with subject's medical imaging under identical laxity condition. METHODS: The laxity test was applied to the anterior-posterior drawer under 90 flexion and the varus valgus under 20 flexion with a series of stress radiographs, a Telos device, and computed tomography. The loading condition in the computational subject-specific knee joint model was identical to the laxity test condition in the medical image. RESULTS: Our computational model showed knee laxity kinematic trends that were consistent with the computed tomography images, except for negligible differences because of the indirect application of the subject's in vivo material properties. CONCLUSIONS: Medical imaging based on computed tomography with the laxity test allowed us to measure not only the precise translation but also the rotation of the knee joint. This methodology will be beneficial in the validation of laxity tests for subject- or patient-specific computational models.
引用
收藏
页码:417 / 429
页数:13
相关论文
共 35 条
  • [1] [Anonymous], APPL MATH IRVINE
  • [2] Efficient probabilistic representation of tibiofemoral soft tissue constraint
    Baldwin, Mark A.
    Laz, Peter J.
    Stowe, Joshua Q.
    Rullkoetter, Paul J.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2009, 12 (06) : 651 - 659
  • [3] Sensitivity of the tibio-femoral response to finite element modeling parameters
    LBMC, French National Institute for Transport and Safety Research, INRETS UCBL1 UMR-T, 9406, Bron, France
    不详
    不详
    [J]. Comput. Methods Biomech. Biomed. Eng., 2007, 3 (209-221): : 209 - 221
  • [4] Validation of a three-dimensional model of the knee
    Blankevoort, L
    Huiskes, R
    [J]. JOURNAL OF BIOMECHANICS, 1996, 29 (07) : 955 - 961
  • [5] Subject-Specific Finite Element Modeling of the Tibiofemoral Joint Based on CT, Magnetic Resonance Imaging and Dynamic Stereo-Radiography Data in Vivo
    Carey, Robert E.
    Zheng, Liying
    Aiyangar, Ameet K.
    Harner, Christopher D.
    Zhang, Xudong
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (04):
  • [6] The anatomical tibial axis - Reliable rotational orientation in knee replacement
    Cobb, J. P.
    Dixon, H.
    Dandachli, W.
    Iranpour, F.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (08): : 1032 - 1038
  • [7] How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint
    Donahue, TLH
    Hull, ML
    Rashid, MM
    Jacobs, CR
    [J]. JOURNAL OF BIOMECHANICS, 2003, 36 (01) : 19 - 34
  • [8] Comparison of eight published static finite element models of the intact lumbar spine: Predictive power of models improves when combined together
    Dreischarf, M.
    Zander, T.
    Shirazi-Adl, A.
    Puttlitz, C. M.
    Adam, C. J.
    Chen, C. S.
    Goel, V. K.
    Kiapour, A.
    Kim, Y. H.
    Labus, K. M.
    Little, J. P.
    Park, W. M.
    Wang, Y. H.
    Wilke, H. J.
    Rohlmann, A.
    Schmidt, H.
    [J]. JOURNAL OF BIOMECHANICS, 2014, 47 (08) : 1757 - 1766
  • [9] INDELICATO PA, 1990, CLIN ORTHOP RELAT R, P174