Imaging of coronary stents using multislice computed tomography

被引:0
|
作者
Seifarth, H. [1 ]
Heindel, W. [1 ]
Maintz, D. [1 ]
机构
[1] Univ Klinikum Munster, Inst Klin Radiol, D-48149 Munster, Germany
来源
RADIOLOGE | 2010年 / 50卷 / 06期
关键词
Coronary CT angiography; Coronary artery stent; Stent restenosis; Edge-enhancing convolution kernel; BALLOON ANGIOPLASTY; ELUTING STENT; DIAGNOSTIC-ACCURACY; ARTERY DISEASE; CT ANGIOGRAPHY; RESTENOSIS; PATENCY; IMPLANTATION; ANTIPLATELET; EXPERIENCE;
D O I
10.1007/s00117-010-1990-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Coronary artery stenting has become the most important form of coronary revascularization. With the introduction of drug-eluting stents (DES) the rate of restenosis has declined but due to the delayed formation of intimal tissue the incidence of late (> 30 days after stent placement) and very late thrombosis of the stents is higher for DES. Visualization of the stent lumen is possible with multislice computed tomography (MSCT) but blooming artifacts hamper the delineation of the stent lumen. The severity of these artifacts and thus the width of the visible stent lumen depends on several factors, such as the thickness of the stent struts, the design of the stent and the underlying material itself. The most important factor influencing the extent of blooming artifacts is the convolution kernel selected for image reconstruction. Dedicated, edge-enhancing kernels offer superior lumen visualization compared to the soft or medium kernels used for coronary artery imaging. The trade-off using edge-enhancing kernels is an increase in image noise. Despite all efforts undertaken to enhance stent lumen visualization, stent imaging is still a challenge in MSCT. In the majority of stents currently used, sufficient lumen visualization is only possible in stents with a diameter larger than 3 mm. A position of the stent in the proximal segments of the coronary artery tree facilitates delineation of the stent lumen not only because of the relatively little motion but also because of the lesser extent of blooming artifacts obscuring the stent lumen if the stent is oriented perpendicular to the z-axis of the scanner.
引用
收藏
页码:507 / +
页数:6
相关论文
共 50 条
  • [1] Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation
    David Maintz
    Kai-Uwe Juergens
    Thomas Wichter
    Matthias Grude
    Walter Heindel
    Roman Fischbach
    European Radiology, 2003, 13 : 830 - 835
  • [2] Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation
    Maintz, D
    Juergens, KU
    Wichter, T
    Grude, M
    Heindel, W
    Fischbach, R
    EUROPEAN RADIOLOGY, 2003, 13 (04) : 830 - 835
  • [3] In vitro visualization of coronary stents with multislice computed tomography
    Nieman, K
    Munne, A
    Pattynama, PM
    De Feyter, PJ
    CIRCULATION, 2001, 104 (17) : 478 - 478
  • [4] Non-invasive multislice computed tomography coronary angiography for imaging coronary arteries, stents and bypass grafts
    Soon, KH
    Kelly, AM
    Cox, N
    Chaitowitz, I
    Bell, KW
    Lim, YL
    INTERNAL MEDICINE JOURNAL, 2006, 36 (01) : 43 - 50
  • [5] Imaging of coronary stent by multislice helical computed tomography
    Zhao, SH
    Nie, YK
    Cai, ZL
    Zhao, H
    Yang, L
    CIRCULATION, 2002, 106 (05) : 637 - 638
  • [6] Causes of longitudinal shortening of coronary stents: evaluation by multislice computed tomography
    Romaguera Torres, R.
    Roura, G.
    Gracida, M.
    Gomez-Lara, J.
    Ferreiro, J. L.
    Teruel, L.
    Sanchez-Elvira, G.
    Peris, S.
    Gomez-Hospital, J. A.
    Cequier, A.
    EUROPEAN HEART JOURNAL, 2014, 35 : 974 - 974
  • [7] Imaging of congenital coronary anomalies with multislice computed tomography
    Deibler, AR
    Kuzo, RS
    Vohringer, M
    Page, EE
    Safford, RE
    Patton, JN
    Lane, GE
    Morin, RL
    Gerber, TC
    MAYO CLINIC PROCEEDINGS, 2004, 79 (08) : 1017 - 1023
  • [8] Assessment of coronary arterial stents by multislice-computed tomography angiography
    Grude, M
    Maintz, D
    Paul, M
    Fischbach, R
    Breithardt, G
    Wichter, T
    EUROPEAN HEART JOURNAL, 2003, 24 : 329 - 329
  • [9] Coronary artery stents in multislice computed tomography -: In vitro artifact evaluation
    Mahnken, AH
    Buecker, A
    Wildberger, JE
    Ruebben, A
    Stanzel, S
    Vogt, F
    Günther, RW
    Blindt, R
    INVESTIGATIVE RADIOLOGY, 2004, 39 (01) : 27 - 33
  • [10] Darstellung von Koronarstents mit der ComputertomographieImaging of coronary stents using multislice computed tomography
    H. Seifarth
    W. Heindel
    D. Maintz
    Der Radiologe, 2010, 50 : 507 - 513