Four-port AC quantized hall resistance measurements

被引:4
|
作者
Ricketts, BW [1 ]
Fiander, JR [1 ]
Johnson, HL [1 ]
Small, GW [1 ]
机构
[1] CSIRO, Natl Measurement Lab, Lindfield, NSW 2070, Australia
关键词
impedance measurement; quantized Hall resistance (QHR); resistance measurement;
D O I
10.1109/TIM.2003.810016
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report four-port measurements of quantized Hall resistances (QHRs) over the frequency range of 200 Hz to 2000 kHz. The importance of capacitive current flow from the conducting layer of the QHR device is illustrated by effectively reversing the polarity of the potentials of a split guard layer in close proximity to the QHR device. The frequency dependence of the current coefficients of the quantized Hall resistances have been investigated.
引用
收藏
页码:579 / 583
页数:5
相关论文
共 50 条
  • [31] Equivalent electrical circuit representations of AC quantized Hall resistance standards
    Cage, ME
    Jeffery, A
    Matthews, J
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1999, 104 (06) : 529 - 556
  • [32] Equivalent electrical circuit representations of AC quantized Hall resistance standards
    Cage, M.E.
    Jeffery, A.
    Matthews, J.
    Journal of Research of the National Institute of Standards and Technology, 104 (06): : 529 - 556
  • [33] Error correction at four-port on-wafer s-parameter measurements
    Mernyei, Ferenc
    Aoki, Ikuro
    Matsuura, Hiroyuki
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1994, 2 : 870 - 873
  • [34] ACCURATE AC MEASUREMENTS OF THE QUANTIZED HALL RESISTANCE FROM 1-HZ TO 1,6-KHZ
    DELAHAYE, F
    METROLOGIA, 1995, 31 (05) : 367 - 373
  • [35] HIGH-PRECISION MEASUREMENTS OF THE QUANTIZED HALL RESISTANCE AT THE PTB
    BLIEK, L
    BRAUN, E
    MELCHERT, F
    WARNECKE, P
    SCHLAPP, W
    WEIMANN, G
    PLOOG, K
    EBERT, G
    DORDA, GE
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1985, 34 (02) : 304 - 305
  • [36] OPTIMIZATION OF THE CONTACT GEOMETRY FOR ACCURATE QUANTIZED HALL RESISTANCE MEASUREMENTS
    DOMINGUEZ, D
    VANKLITZING, K
    PLOOG, K
    METROLOGIA, 1989, 26 (03) : 197 - 201
  • [37] HIGH PRECISION MEASUREMENTS OF THE QUANTIZED HALL RESISTANCE AT THE PTB.
    Bliek, Leendert
    Braun, Erich
    Melchert, Friedmund
    Warnecke, Peter
    Schlapp, W.
    Weimann, G.
    Ploog, Klaus
    Ebert, Gunther
    Dorda, Gerhard E.
    IEEE Transactions on Instrumentation and Measurement, 1984, IM-34 (02)
  • [38] Suggested triple-series connection measurement tests of the ac quantized Hall resistance and the ac longitudinal resistance
    Cage, ME
    Jeffery, A
    Elmquist, RE
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 341 - 342
  • [39] Two-port versus four-port laparoscopic cholecystectomy
    C. M. Poon
    K. W. Chan
    D. W. H. Lee
    K. C. Chan
    C. W. Ko
    H. Y. Cheung
    K. W. Lee
    Surgical Endoscopy And Other Interventional Techniques, 2003, 17 (10): : 1624 - 1627
  • [40] Three-port versus four-port laparoscopic cholecystectomy
    Cerci, Celal
    Tarhan, Omer Ridvan
    Barut, Ibrahim
    Bulbul, Mahmut
    HEPATO-GASTROENTEROLOGY, 2007, 54 (73) : 15 - 16