Clinical Implications of Conduction Abnormalities and Arrhythmias After Transcatheter Aortic Valve Implantation

被引:15
|
作者
van der Boon, Robert M. A. [1 ]
Houthuizen, Patrick [2 ,3 ]
Nuis, Rutger-Jan [1 ]
van Mieghem, Nicolas M. [1 ]
Prinzen, Frits [3 ]
de Jaegere, Peter P. T. [1 ]
机构
[1] Erasmus MC, Thoraxctr, Dept Intervent Cardiol, Rotterdam, Netherlands
[2] Catharina Hosp, Dept Cardiol, Eindhoven, Netherlands
[3] Cardiovasc Res Inst Maastricht, Maastricht, Netherlands
关键词
Transcatheter aortic valve implantation (TAVI); Conduction abnormalities; Arrhythmias; Left bundle branch block; Atrioventricular block; Permanent pacemaker implantation; Atrial fibrillation; BUNDLE-BRANCH-BLOCK; CARDIAC-RESYNCHRONIZATION THERAPY; PREOPERATIVE ATRIAL-FIBRILLATION; PERMANENT PACEMAKER IMPLANTATION; PREDICTIVE FACTORS; PROGNOSTIC IMPLICATIONS; ATRIOVENTRICULAR-BLOCK; ELECTRICAL DELAY; FOLLOW-UP; REPLACEMENT;
D O I
10.1007/s11886-013-0429-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter aortic valve implantation (TAVI) has become an established treatment option for patients with aortic stenosis at prohibitive risk to undergo surgical aortic valve replacement. Despite conveying obvious clinical benefits and a decreasing frequency of complications, the occurrence of new conduction abnormalities and arrhythmias remains an important issue. Generally considered a minor complication, they may have a profound impact on prognosis and quality of life after TAVI. Therefore the purpose of this review is to assess and discuss the available information on clinical implications of both new conduction abnormalities and arrhythmias after TAVI.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Mitral Annulus Calcium Score An Independent Predictor of New Conduction System Abnormalities in Patients After Transcatheter Aortic Valve Implantation
    Brodov, Yafim
    Konen, Eli
    Di Segni, Mattia
    Samoocha, David
    Chernomordik, Fernando
    Barbash, Israel
    Regev, Ehud
    Raanani, Ehud
    Guetta, Victor
    Segev, Amit
    Fefer, Paul
    Glikson, Michael
    Goitein, Orly
    CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (01)
  • [22] Pathophysiology, incidence and predictors of conduction disturbances during Transcatheter Aortic Valve Implantation
    Barbanti, Marco
    Gulino, Simona
    Costa, Giuliano
    Tamburino, Corrado
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (02) : 135 - 147
  • [23] Rate and Predictors of Permanent Pacemaker Implantation after Transcatheter Aortic Valve Implantation: Current Status
    Russo, Elconora
    Potenza, Domenico R.
    Casclla, Michela
    Massaro, Raimondo
    Russo, Giulio
    Braccio, Maurizio
    Dello Russo, Antonio
    Cassese, Mauro
    CURRENT CARDIOLOGY REVIEWS, 2019, 15 (03) : 205 - 218
  • [24] Membranous septum morphology and risk of conduction abnormalities after transcatheter aortic valve implantation
    Jorgensen, Troels Hojsgaard
    Hansson, Nicolaj
    De Backer, Ole
    Bieliauskas, Gintautas
    Terkelsen, Christian Juhl
    Wang, Xi
    Jensen, Jesper Moller
    Christiansen, Evald Hoj
    Piazza, Nicolo
    Svendsen, Jesper Hastrup
    Norgaard, Bjarne Linde
    Sondergaard, Lars
    EUROINTERVENTION, 2022, 17 (13) : 1061 - +
  • [25] Use of Electrophysiological Studies in Transcatheter Aortic Valve Implantation
    Tovia-Brodie, Oholi
    Michowitz, Yoav
    Belhassen, Bernard
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2020, 9 (01) : 20 - 27
  • [26] Prosthesis depth and conduction disturbances after last generation balloon-expandable transcatheter aortic valve implantation
    Iacovelli, Fortunato
    Pignatelli, Antonio
    Giugliano, Giuseppe
    Stabile, Eugenio
    Cicala, Mariangela
    Salemme, Luigi
    Cioppa, Angelo
    Popusoi, Grigore
    Pucciarelli, Armando
    Verdoliva, Sebastiano
    Bortone, Alessandro Santo
    Losi, Maria-Angela
    Coscioni, Enrico
    Esposito, Giovanni
    Contegiacomo, Gaetano
    Tesorio, Tullio
    EUROPACE, 2018, 20 (01): : 116 - 123
  • [27] Conduction delays after transcatheter aortic valve implantation with balloon-expandable prosthesis and high implantation technique
    Iacovelli, Fortunato
    Giugliano, Giuseppe
    Gerardi, Donato
    Salemme, Luigi
    Cioppa, Angelo
    Pucciarelli, Armando
    Popusoi, Grigore
    Loizzi, Francesco
    Schettino, Giancarlo
    Favale, Stefano
    Solimene, Francesco
    Esposito, Giovanni
    Tesorio, Tullio
    Stabile, Eugenio
    HEART AND VESSELS, 2022, 37 (02) : 337 - 346
  • [28] Incidence and predictors of left bundle branch block after transcatheter aortic valve implantation
    Aktug, Oemer
    Dohmen, Guido
    Brehmer, Kathrin
    Koos, Ralph
    Altiok, Ertunc
    Deserno, Verena
    Herpertz, Ralf
    Autschbach, Ruediger
    Marx, Nikolaus
    Hoffmann, Rainer
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 160 (01) : 26 - 30
  • [29] Severe conduction defects requiring permanent pacemaker implantation in patients with a new-onset left bundle branch block after transcatheter aortic valve implantation
    Nijenhuis, V. J.
    Van Dijk, V. F.
    Chaldoupi, S. M.
    Balt, J. C.
    Ten Berg, J. M.
    EUROPACE, 2017, 19 (06): : 1015 - 1021
  • [30] Clinical Impact of Intraventricular Conduction Abnormalities After Transcatheter Aortic Valve Implantation With Balloon-Expandable Valves
    Miura, Mizuki
    Shirai, Shinichi
    Uemura, Yukari
    Hayashi, Masaomi
    Takiguchi, Hiroshi
    Ito, Shinya
    Yano, Mariko
    Kawaguchi, Tomohiro
    Morinaga, Takashi
    Isotani, Akihiro
    Kakumoto, Shinichi
    Seo, Katsuhiro
    Arai, Yoshio
    Sakaguchi, Genichi
    Ando, Kenji
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 123 (02) : 297 - 305