Atrial pacing leads following open heart surgery: Active or passive fixation?

被引:5
作者
Connelly, DT [1 ]
Steinhaus, DM [1 ]
Handlin, L [1 ]
Lemery, R [1 ]
Moutray, K [1 ]
Foley, L [1 ]
Davie, S [1 ]
Cardinal, D [1 ]
Lipke, J [1 ]
机构
[1] ST LUKES HOSP,MID AMER HEART INST,KANSAS CITY,MO 64111
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1997年 / 20卷 / 10期
关键词
D O I
10.1111/j.1540-8159.1997.tb06082.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The right atrial appendage is often amputated at the time of cardiopulmonary bypass. Because of concerns regarding lead displacement, use of active fixation atrial leads has been recommended in patients who require permanent atrial or dual chamber pacing after open heart surgery. We evaluated the acute and chronic performance of active and passive fixation atrial leads implanted at our institution between 1985 and 1993 in patients with previous open heart surgery. Of 78 consecutive patients, 38 had an active fixation atrial lead, 28 had a passive fixation steroid-eluting lead, and 12 had a passive fixation lead without steroid-eluting properties. At implantation, sensed P wave amplitudes were similar in the three groups, but lead impedance and threshold were significantly higher for active fixation leads compared to all passive fixation leads. During follow-up, atrial pacing thresholds were significantly higher, and sensed P wave amplitudes significantly lower, in the patients with active fixation leads compared to those with passive fixation leads. Loss of sensing occurred in 6 of 38 (16%) patients with active fixation leads and 1 of 40 (2.5%) patients with a passive fixation lead (P = 0.027). Atrial lead displacement occurred in two patients with active fixation leads and one with a passive fixation lead. Comparison with a parallel group of patients without previous open heart surgery demonstrated that atrial lead performance was similar in the two groups. We conclude that, when permanent atrial or dual chamber pacing is necessary in patients with prior open heart surgery, it is appropriate to implant a passive fixation atrial lead except on the infrequent occasions when a stable atrial position cannot be obtained.
引用
收藏
页码:2429 / 2433
页数:5
相关论文
共 14 条
[1]   ACTIVE FIXATION LEADS - LONG-TERM THRESHOLD REDUCTION USING A DRUG-INFUSED CERAMIC COLLAR [J].
ANDERSON, N ;
MATHIVANAR, R ;
SKALSKY, M ;
TUNSTELL, A ;
NG, M ;
HARMAN, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11) :1767-1771
[2]  
BELOTT PH, 1995, CLIN CARDIAC PACING, P447
[3]  
BOGNOLO D, 1981, PACE, V4, pA35
[4]   PERMANENT TRANSVENOUS ATRIAL-PACING AFTER HEART-SURGERY [J].
BOGNOLO, DA ;
VIJAYANAGAR, RR ;
ECKSTEIN, PF ;
JEFFERY, DL ;
RENDINA, E ;
MORELLI, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1982, 5 (06) :870-872
[5]  
ELGAMAL MIH, 1985, CARDIAC PACING ELECT, P649
[6]   A NEW STEROID-ELUTING SCREW-IN ELECTRODE [J].
FROHOLIG, G ;
SCHWAAB, B ;
SCHWERDT, H ;
LAWALL, P ;
TRENDELENBURG, M ;
SCHIEFFER, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (06) :1134-1142
[7]   ACTIVE FIXATION ATRIAL LEADS - RANDOMIZED COMPARISON OF 2 LEAD DESIGNS [J].
KAY, GN ;
ANDERSON, K ;
EPSTEIN, AE ;
PLUMB, VJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (08) :1355-1361
[8]   COMPARISON OF UNIPOLAR AND BIPOLAR ACTIVE FIXATION ATRIAL-PACING LEADS [J].
KAY, GN ;
EPSTEIN, AE ;
PLUMB, VJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (05) :544-549
[9]  
KERR CR, 1985, PACE, V8, P487
[10]   NECROPSY STUDY OF RIGHT ATRIAL APPENDAGE - MORPHOLOGY AND QUANTITATIVE MEASUREMENTS [J].
MANOLIS, AS ;
VARRIALE, P ;
BAPTIST, SJ .
CLINICAL CARDIOLOGY, 1988, 11 (11) :788-792