Study of mass transfer in a dynamic hollow-fibre liquid phase microextraction system

被引:7
作者
Hansson, Helena [1 ]
Colmsjo, Anders [1 ]
Nilsson, Ulrika [1 ]
机构
[1] Stockholm Univ, Dept Analyt Chem, S-10691 Stockholm, Sweden
关键词
Diffusion; Hollow-fibre liquid-phase microextraction; Human blood plasma; Nitrophenols; Supported liquid membrane; MEMBRANE EXTRACTION; CHROMATOGRAPHY; SAMPLES; DINITROPHENOLS;
D O I
10.1002/jssc.200900539
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The extraction characteristics of a dynamic hollow-fibre liquid phase microextraction system were investigated by studying the mass transfer and diffusion rates of dinitrophenols from plasma samples over the liquid membrane (dihexylether). The measured diffusion coefficients were compared with theoretical values calculated from Stokes diameters. The diffusion mechanism was simulated by computer and the most polar compounds, 2,4-dinitrophenol and 4,6-o-dinitrocresol, had associated diffusion coefficients that were close to the calculated theoretical values. 2-sec-Butyl-4,6 dinitrophenol and 2-tent-butyl-4,6-dinitrophenol, the compounds with the highest log P values, were retained by the polypropylene membrane, which reduced the experimentally observed diffusion rates to about half of the theoretical values. The retention was most likely due to dispersive forces interacting with the pore inner walls. Extraction was linearly correlated with time for all compounds and the repeatability was high (RSDs 7-11%), even for the shortest extraction times. Method LOD as the amount injected ranged between 0.3 and 3.1 ng for an extraction cycle of 213 s.
引用
收藏
页码:112 / 119
页数:8
相关论文
共 23 条
[1]   Advances and developments in membrane extraction for gas chromatography -: Techniques and applications [J].
Barri, Thaer ;
Jonsson, Jan-Ake .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) :16-38
[2]   Determination of trace levels of dinitrophenolic compounds in environmental water samples using hollow fiber supported liquid membrane extraction and high performance liquid chromatography [J].
Berhanu, T ;
Liu, JF ;
Romero, R ;
Megersa, N ;
Jönsson, JÅ .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1103 (01) :1-8
[3]   Dynamic hollow-fibre liquid phase microextraction of dinitrophenols from human plasma: Optimization of an extraction flow system using experimental design methodology [J].
Hansson, Helena ;
Lagerstrom, Malene ;
Aberg, Magnus ;
Nilsson, Ulrika .
TALANTA, 2009, 79 (03) :633-638
[4]   Assessment of a dynamic hollow-fibre liquid phase microextraction system for human blood plasma samples [J].
Hansson, Helena ;
Nilsson, Ulrika .
TALANTA, 2009, 77 (04) :1309-1314
[5]   Automated, on-line membrane extraction [J].
Hylton, Kamilah ;
Mitra, Somenath .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) :199-214
[6]   Sorbent- and liquid-phase microextraction techniques and membrane-assisted extraction in combination with gas chromatographic analysis:: A review [J].
Hyotylainen, Tuulia ;
Riekkola, Marja-Liisa .
ANALYTICA CHIMICA ACTA, 2008, 614 (01) :27-37
[7]  
Jönsson JÅ, 2001, J SEP SCI, V24, P495, DOI 10.1002/1615-9314(20010801)24:7<495::AID-JSSC495>3.0.CO
[8]  
2-B
[9]   Liquid membrane extraction in analytical sample preparation I.: Principles [J].
Jönsson, JÅ ;
Mathiasson, L .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (05) :318-325
[10]   Liquid-phase micro-extraction techniques in pesticide residue analysis [J].
Lambropoulou, Dimitra A. ;
Albanis, Triantafyllos A. .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2007, 70 (02) :195-228