Electrocatalytic determination of thiols using hybrid copper cobalt hexacyanoferrate modified glassy carbon electrode

被引:20
|
作者
Sharma, Vivek Vishal [1 ]
Guadagnini, Lorella [1 ]
Giorgetti, Marco [1 ]
Tonelli, Domenica [1 ]
机构
[1] Univ Bologna, Dipartimento Chim Ind Toso Montanari, Viale Risorgimento 4, I-40136 Bologna, Italy
关键词
Hexacyanoferrates; Electrosynthesis; Glassy carbon; L-Cysteine; 1,4-Butanedithiol; L-Glutathione; L-CYSTEINE; HYDROGEN-PEROXIDE; LIQUID-CHROMATOGRAPHY; GLUTATHIONE; HOMOCYSTEINE; ENHANCEMENT; STABILITY; PALLADIUM; OXIDATION; IDENTITY;
D O I
10.1016/j.snb.2015.12.067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical sensor based on a glassy carbon electrode (GCE) modified by a thin film of hybrid copper cobalt hexacyanoferrate (Cu-CoHCF) was prepared and tested for the determination of three thiols: L-cysteine (CySH), L-glutathione (GSH) and 1,4-butanedithiol (BdSH). Cyclic voltammetry (CV) measurements were carried out with the as prepared and thermally treated chemically modified electrode (CME) in phosphate buffer solution from pH 2 to 7. From the CV measurements, it was concluded that at pH higher than 5, the Cu-CoHCF layer was unstable and underwent significant fouling when biased at a potential at which the three thiols were electrocatalically oxidized. Following the preliminary CVs chronoamperometric measurements were carried out to determine the optimum conditions to develop an analytical method for the determination of thiols. Cysteine showed the lowest limit of detection (7.5 x 10(-7) M), but very low values were displayed also by GSH (2.5 x 10(-6)M) and BdSH (2.0 x 10(-6) M). The range of linearity extended up to 6.0 x 10(-5)M for CySH, 9.0 x 10(-6)M for GSH and 1.2 x 10(-4)M for BdSH without significant fouling of the CME. The analytical method was applied to the determination of GSH in a nutraceutical purchased from the local market. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 50 条
  • [41] Determination of cyanide in wastewaters using modified glassy carbon electrode with immobilized silver hexacyanoferrate nanoparticles on multiwall carbon nanotube
    Noroozifar, Meissam
    Khorasani-Motlagh, Mozhgan
    Taheri, Aboozar
    JOURNAL OF HAZARDOUS MATERIALS, 2011, 185 (01) : 255 - 261
  • [42] Electrocatalytic oxidation of aspirin and acetaminophen on a cobalt hydroxide nanoparticles modified glassy carbon electrode
    Houshmand, M.
    Jabbari, A.
    Heli, H.
    Hajjizadeh, M.
    Moosavi-Movahedi, A. A.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2008, 12 (09) : 1117 - 1128
  • [43] Electrocatalytic oxidation of aspirin and acetaminophen on a cobalt hydroxide nanoparticles modified glassy carbon electrode
    M. Houshmand
    A. Jabbari
    H. Heli
    M. Hajjizadeh
    A. A. Moosavi-Movahedi
    Journal of Solid State Electrochemistry, 2008, 12 : 1117 - 1128
  • [44] Kinetic Study of Electrocatalytic Oxidation of Carbohydrates on Cobalt Hydroxide Modified Glassy Carbon Electrode
    Karim-Nezhad, Ghasem
    Hasanzadeh, Mohammad
    Saghatforoush, Lotfali
    Shadjou, Nasrin
    Earshad, Sohrab
    Khalilzadeh, Balal
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (01) : 141 - 151
  • [45] Preparation of bilayer platinum and copper hexacyanoferrate hybrid film modified electrode and its electrocatalytic properties
    Chen, Shen-Ming
    Li, Sheh-Hung
    Thiagarajan, Soundappan
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2007, 154 (08) : E123 - E130
  • [46] Electrode modified with cobalt hexacyanoferrate for amperometric determination of hydrazine
    Shankaran, D.R.
    Narayanan, S.S.
    Elektrokhimiya, 2002, 38 (09): : 1098 - 1103
  • [47] Investigation of a Polyaniline-Coated Copper Hexacyanoferrate Modified Glassy Carbon Electrode as a Sulfite Sensor
    Yang, Yongfeng
    Yan, Yun
    Chen, Xinfang
    Zhai, Wenying
    Xu, Yuehua
    Liu, Youqin
    ELECTROCATALYSIS, 2014, 5 (04) : 344 - 353
  • [48] Investigation of a Polyaniline-Coated Copper Hexacyanoferrate Modified Glassy Carbon Electrode as a Sulfite Sensor
    Yongfeng Yang
    Yun Yan
    Xinfang Chen
    Wenying Zhai
    Yuehua Xu
    Youqin Liu
    Electrocatalysis, 2014, 5 : 344 - 353
  • [49] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Department of Pharmacy, Faculty of Medicine, University of Banja Luka, Save Mrkalja 14, Banja Luka
    78000, Bosnia and Herzegovina
    不详
    11000, Serbia
    不详
    11000, Serbia
    不详
    78000, Bosnia and Herzegovina
    Anal. Sci., 2 (353-358):
  • [50] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Vesna Antunović
    Tatjana Tripković
    Biljana Tomašević
    Rada Baošić
    Dijana Jelić
    Aleksandar Lolić
    Analytical Sciences, 2021, 37 (2) : 353 - 358