Extraction of Ascorbate Oxidase from Cucurbita maxima by Continuous Process in Perforated Rotating Disc Contactor Using Aqueous Two-Phase Systems

被引:14
作者
Porto, T. S. [1 ,2 ]
Marques, P. P. [1 ]
Porto, C. S. [1 ]
Moreira, K. A. [1 ,3 ]
Lima-Filho, J. L. [1 ]
Converti, A. [4 ]
Pessoa, A. [2 ]
Porto, A. L. F. [1 ,5 ]
机构
[1] Univ Fed Pernambuco, LIKA, BR-50670901 Recife, PE, Brazil
[2] Univ Sao Paulo, Dept Biochem & Pharmaceut Technol, Sao Paulo, Brazil
[3] Univ Fed Rural Pernambuco, Acad Unit Garanhuns, Recife, PE, Brazil
[4] Univ Genoa, Dept Chem & Proc Engn, Genoa, Italy
[5] Univ Fed Rural Pernambuco, Dept Anim Morphol & Physiol, Recife, PE, Brazil
基金
巴西圣保罗研究基金会;
关键词
Ascorbate oxidase; ATPS; Continuous extraction; Cucurbita maxima; PRDC; MASS-TRANSFER; PROTEIN EXTRACTION; FERMENTED BROTH; CRUDE EXTRACT; RECOVERY; HYDRODYNAMICS; PERFORMANCE; PREDICTION; COLUMN;
D O I
10.1007/s12010-009-8631-y
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The ascorbate oxidase is the enzyme used to determine the content of ascorbic acid in the pharmaceutical and food industries and clinics analyses. The techniques currently used for the purification of this enzyme raise its production cost. Thus, the development of alternative processes and with the potential to reduce costs is interesting. The application of aqueous two-phase system is proposed as an alternative to purification because it enables good separation of biomolecules. The objective of this study was to determine the conditions to continuously pre-purify the enzyme ascorbate oxidase by an aqueous two-phase system (PEG/citrate) using rotating column provided with perforated discs. Under the best conditions (20,000 g/mol PEG molar mass, 10% PEG concentration, and 25% citrate concentration), the system showed satisfactory results (partition coefficient, 3.35; separation efficiency, 54.98%; and purification factor, 1.46) and proved suitable for the pre-purification of ascorbate oxidase in continuous process.
引用
收藏
页码:1057 / 1064
页数:8
相关论文
共 21 条
  • [11] Prediction of the hydrodynamics of rotating disc contactors based on a new Monte-Carlo simulation method for drop breakage
    Ghalehchian, JS
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2002, 35 (07) : 604 - 612
  • [12] Mass transfer in aqueous two-phases system packed column
    Igarashi, L
    Kieckbusch, TG
    Franco, TT
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 807 (01): : 75 - 80
  • [13] Prediction of continuous phase axial mixing in rotating disc contactors
    Murugesan, T
    Regupathi, I
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2004, 37 (10) : 1293 - 1302
  • [14] Pessoa A., 2005, PURIFICACAO PRODUTOS
  • [15] Hydrodynamics and mass transfer in aqueous two-phase protein extraction using a continuous perforated rotating disc contactor
    Porto, ALF
    Sarubbo, LA
    Lima, JL
    Aires-Barros, MR
    Cabral, JMS
    Tambourgi, EB
    [J]. BIOPROCESS ENGINEERING, 2000, 22 (03) : 215 - 218
  • [16] Recovery of ascorbic oxidoreductase from crude extract with an aqueous two-phase system in a perforated rotating disc contactor
    Porto, ALF
    Sarubbo, LA
    Moreira, KA
    de Melo, HJF
    Lima-Filho, JL
    Campos-Takaki, GM
    Tambourgi, EB
    [J]. BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2004, 47 (05) : 821 - 826
  • [17] Liquid-liquid extraction of proteases from fermented broth by PEG/citrate aqueous two-phase system
    Porto, T. S.
    Medeiros e Silva, G. M.
    Porto, C. S.
    Cavalcanti, M. T. H.
    Neto, B. B.
    Lima-Filho, J. L.
    Converti, A.
    Porto, A. L. F.
    Pessoa, A., Jr.
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2008, 47 (04) : 716 - 721
  • [18] Performance of a pulsed-cap microcolumn for protein extraction
    Rabelo, APB
    Tambourgi, EB
    [J]. BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 20 (04) : 357 - 362
  • [19] Practical application of aqueous two-phase partition to process development for the recovery of biological products
    Rito-Palomares, M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 807 (01): : 3 - 11
  • [20] Performance of a perforated rotating disc contactor in the continuous extraction of a protein using the PEG-cashew-nut tree gum aqueous two-phase system
    Sarubbo, LA
    Oliveira, LA
    Porto, ALF
    Lima-Filho, JL
    Campos-Takaki, GM
    Tambourgi, EB
    [J]. BIOCHEMICAL ENGINEERING JOURNAL, 2003, 16 (03) : 221 - 227