Bio-impedance identifies an elevated extracellular fluid volume in hypoalbuminemic CAPD patients.

被引:0
|
作者
Jones, CH
Smye, SW
Newstead, CG
Will, EJ
Davison, AM
机构
[1] ST JAMES UNIV HOSP,DEPT RENAL MED,LEEDS LS9 7TF,W YORKSHIRE,ENGLAND
[2] ST JAMES UNIV HOSP,DEPT MED PHYS,LEEDS LS9 7TF,W YORKSHIRE,ENGLAND
关键词
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:1120 / 1120
页数:1
相关论文
共 50 条
  • [1] Measurement of extracellular fluid volume in the neonate using multiple frequency bio-impedance analysis
    Lingwood, BE
    Coghlan, JP
    Ward, LC
    Charles, BG
    Colditz, PB
    PHYSIOLOGICAL MEASUREMENT, 2000, 21 (02) : 251 - 262
  • [2] Extracellular fluid volume determined by bioelectric impedance and serum albumin in CAPD patients
    Jones, CH
    Smye, SW
    Newstead, CG
    Will, EJ
    Davison, AM
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (02) : 393 - 397
  • [3] Generalizability of extracellular-to-intracellular fluid ratio using bio-impedance spectroscopy
    Turner, AA
    Lozano-Nieto, A
    Bouffard, M
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (04) : 385 - 397
  • [4] Volume Status in Patients on Peritoneal Dialysis: The Role of Apelin and Bio-Impedance Spectroscopy
    Kazancioglu, Rumeyza
    Gursu, Meltem
    Karadag, Serhat
    Tatli, Emel
    Aydin, Zeki
    Uzun, Sami
    Sumnu, Abdullah
    Cebeci, Egemen
    Ozturk, Savas
    RENAL FAILURE, 2012, 34 (09) : 1068 - 1073
  • [5] Relation between residual urinary volume and peritoneal fluid kinetics in CAPD patients.
    VanOlden, RW
    Struijk, DG
    Hirallal, K
    Gorgels, JPMC
    Arisz, L
    Krediet, RT
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1997, 8 : A1346 - A1346
  • [6] Intercompartmental fluid shifts monitored by multifrequency bio-impedance spectroscopy (BIS).
    Zaluska, WT
    Schneditz, D
    Kaufman, AM
    Morris, AT
    Levin, NW
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A0887 - A0887
  • [7] Body fluid status assessment by bio-impedance analysis in patients presenting to the emergency department with dyspnea
    Park, Chan Soon
    Lee, Sang-Eun
    Cho, Hyun-Jai
    Kim, Yong-Jin
    Kang, Hyun-Jae
    Oh, Byung-Hee
    Lee, Hae-Young
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2018, 33 (05): : 911 - +
  • [8] BIO-IMPEDANCE MEASUREMENT ALLOWS DISPLAYING THE EARLY STAGES OF NEUTROPHIL EXTRACELLULAR TRAPS
    Linnemann, Caren
    Venturelli, Sascha
    Konrad, Franziska
    Nussler, Andreas K.
    Ehnert, Sabrina
    EXCLI JOURNAL, 2020, 19 : 1481 - 1495
  • [9] ASSOCIATION OF VASCULAR ACCESS FLOW AND VOLUME STATUS ON FISTULA ARM BY BIO-IMPEDANCE ANALYSIS IN HEMODIALYSIS PATIENTS
    Kim, Hyung Jong
    Ko, Eun Jung
    Lee, Younhee
    Jung, Hun
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 : 273 - 273
  • [10] MULTIFREQUENCY IMPEDANCE MEASUREMENTS OF EXTRACELLULAR FLUID VOLUME
    WITHERS, P
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 (01) : 71 - 73