Subchondral bone and cartilage thickness from MRI: effects of chemical-shift artifact

被引:36
作者
McGibbon, CA
Bencardino, J
Palmer, WE
机构
[1] Massachusetts Gen Hosp, Dept Orthopaed, Biomot Lab, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
subchondral bone; articular cartilage; chemical-shift artifact; thickness; magnetic resonance imaging;
D O I
10.1007/s10334-003-0001-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging (MRI) is the modality of choice for visualizing and quantifying articular cartilage thickness. However, difficulties persist in MRI of subchondral bone using spoiled gradient-echo (SPGR) and other gradient-echo sequences, primarily due to the effects of chemical-shift artifact. Fat-suppression techniques are often used to reduce these artifacts, but they prevent measurement of bone thickness. In this report, we assess the magnitude of chemical-shift effects (phase-cancellation and misregistration artifacts) on subchondral bone and cartilage thickness measurements in human femoral heads using a variety of pulse sequence parameters. Phase-cancellation effects were quantified by comparing measurements from in-phase images (TE = 13.5 ms) to out-of-phase images (TE = 15.8 ms). We also tested the assumption of the optimal in-phase TE by comparing thickness measures at small variations on TE (13.0, 13.5 and 14.0 ms). Misregistration effects were quantified by comparing measurements from water+fat images (water-only+fat-only images) to the measurements from in-phase (TE = 13.5) images. A correction algorithm was developed and applied to the in-phase measurements and then compared to measurements from water+fat images. We also compared thickness measurements at different image resolutions. Results showed that both phase-cancellation artifact and misregistration artifact were significant for bone thickness measurement, but not for cartilage thickness measurement. Using an in-phase TE and correction algorithm for misregistration artifact, the errors in bone thickness relative to water+fat images were non-significant. This information may be useful for developing pulse sequences for optimal imaging of both cartilage and subchondral bone.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 52 条
[1]   Treatment of bone-marrow oedema of the talus with the prostacyclin analogue iloprost - An MRI-controlled investigation of a new method [J].
Aigner, N ;
Petje, G ;
Steinboeck, G ;
Schneider, W ;
Krasny, C ;
Landsiedl, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :855-858
[2]   MR phase imaging to quantify bone volume fraction: Computer simulations and in vivo measurements [J].
Allein, S ;
Mihalopoulou, E ;
Luypaert, R ;
Louis, O ;
Panayiotakis, G ;
Eisendrath, H .
MAGNETIC RESONANCE IMAGING, 2000, 18 (03) :275-279
[3]  
Bailey AJ, 1997, GERONTOLOGY, V43, P296
[4]   Trabecular structure assessment in lumbar vertebrae specimens using quantitative magnetic resonance imaging and relationship with mechanical competence [J].
Beuf, O ;
Newitt, DC ;
Mosekilde, L ;
Majumdar, S .
JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (08) :1511-1519
[5]   Consistent fat suppression with compensated spectral-spatial pulses [J].
Block, W ;
Pauly, J ;
Kerr, A ;
Nishimura, D .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :198-206
[6]   Three-point Dixon chemical-shift imaging for evaluating articular cartilage defects in the knee joint on a low-field-strength open magnet [J].
Bredella, MA ;
Losasso, C ;
Moelleken, SC ;
Huegli, RW ;
Genant, HK ;
Tirman, PFJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1371-1375
[7]  
Brown M.A., 1999, MRI BASIC PRINCIPLES
[8]  
Burr DB, 1997, MICROSC RES TECHNIQ, V37, P343, DOI 10.1002/(SICI)1097-0029(19970515)37:4<343::AID-JEMT9>3.0.CO
[9]  
2-L
[10]   High-resolution MRI detects cartilage swelling at the early stages of experimental osteoarthritis [J].
Calvo, E ;
Palacios, I ;
Delgado, E ;
Ruiz-Cabello, J ;
Hernández, P ;
Sánchez-Pernaute, O ;
Egido, J ;
Herrero-Beaumont, G .
OSTEOARTHRITIS AND CARTILAGE, 2001, 9 (05) :463-472