Cerebral hemodynamics and the role of transcranial Doppler applications in the assessment and management of cerebral arteriovenous malformations

被引:15
作者
Busch, Kathryn J. [1 ]
Kiat, Hosen [1 ]
Stephen, Michael [1 ]
Simons, Mary [2 ]
Avolio, Alberto [1 ]
Morgan, Michael Kerin [1 ]
机构
[1] Macquarie Univ, Fac Med & Hlth Sci, Suite 202,2 Technol Pl, Sydney, NSW 2109, Australia
[2] Macquarie Univ, Macquarie Univ Lib, Sydney, NSW 2109, Australia
关键词
Arteriovenous malformation; Doppler; Hemodynamics; Management; Transcranial; Ultrasound; CODED DUPLEX SONOGRAPHY; BLOOD-FLOW-VELOCITY; REAL-TIME SONOGRAPHY; AGE-DEPENDENCE; ULTRASOUND; ARTERIES; EMBOLIZATION; REACTIVITY; DISEASE; AVMS;
D O I
10.1016/j.jocn.2016.01.029
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Dramatic hemodynamic changes occur following resection of brain arteriovenous malformations (AVM). Transcranial Doppler (TCD) records non-invasive velocity and pulsatility parameters. We undertook a systematic review to assess AVM hemodynamics including the time course of changes in velocity and pulsatility in patients undergoing AVM resection. The review employed the Embase and Medline databases. A search strategy was designed. An initial title search for clinical series on AVM and TCD was performed followed by a search for reports on AVM and TCD. A total of 283 publications were selected. Full text analysis produced 54 studies with extractable data regarding AVM, velocity and pulsatility. Two TCD techniques were utilized: conventional "blind" TCD (blind TCD); and transcranial color duplex Doppler (TCCD). Of these, 23 publications reported on blind TCD and seven on TCCD. The presence of high velocity and low pulsatility within AVM feeding arteries preoperatively followed by a postoperative decrease in velocity and subsequent increase in pulsatility of feeding arteries is established. The time sequence of hemodynamic changes following AVM resection using TCD remains uncertain, confounded by variations in methodology and timing of perioperative measurements. Of the two techniques, TCCD reported qualitative aspects including improved differentiation of feeding arteries from draining veins. However, there are a limited number of studies supporting this conclusion. Furthermore, none report reproducible changes with time from treatment. TCCD appears to be a useful technique to analyze the hemodynamic changes occurring following treatment of AVM, however little data is available. This is a field of research that is appropriate to pursue. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 46 条
[1]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[2]   Evaluation of arteriovenous malformations (AVMs) with transcranial color-coded duplex sonography - Does the location of an AVM influence its sonographic detection? [J].
Bartels, E .
JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (11) :1511-1517
[3]   Contrast-enhanced transcranial color-coded duplex sonography in ischemic cerebrovascular disease [J].
Baumgartner, RW ;
Arnold, M ;
Gonner, F ;
Staikow, I ;
Herrmann, C ;
Rivoir, A ;
Muri, RM .
STROKE, 1997, 28 (12) :2473-2478
[4]   Transcranial colour-coded duplex sonography of cerebral arteriovenous malformations [J].
Baumgartner, RW ;
Mattle, HP ;
Schroth, G .
NEURORADIOLOGY, 1996, 38 (08) :734-737
[5]   Transcranial color-coded duplex sonography [J].
Baumgartner, RW .
JOURNAL OF NEUROLOGY, 1999, 246 (08) :637-647
[6]   IMAGING OF CEREBRAL ARTERIOVENOUS-MALFORMATIONS BY TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY [J].
BECKER, GM ;
WINKLER, J ;
HOFFMANN, E ;
BOGDAHN, U .
NEURORADIOLOGY, 1990, 32 (04) :280-288
[7]   AGE DEPENDENCE OF FLOW VELOCITIES IN BASAL CEREBRAL-ARTERIES [J].
BODE, H ;
WAIS, U .
ARCHIVES OF DISEASE IN CHILDHOOD, 1988, 63 (06) :606-611
[8]   CONTRAST-ENHANCED TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY - RESULTS OF A PHASE-2 STUDY [J].
BOGDAHN, U ;
BECKER, G ;
SCHLIEF, R ;
REDDIG, J ;
HASSEL, W .
STROKE, 1993, 24 (05) :676-684
[9]   TRANSCRANIAL DOPPLER MEASUREMENTS OF THE MIDDLE CEREBRAL-ARTERY - EFFECT OF HEMATOCRIT [J].
BRASS, LM ;
PAVLAKIS, SG ;
DEVIVO, D ;
PIOMELLI, S ;
MOHR, JP .
STROKE, 1988, 19 (12) :1466-1469
[10]   TRANSCRANIAL PULSED DOPPLER MEASUREMENTS OF BLOOD-FLOW VELOCITY IN THE MIDDLE CEREBRAL-ARTERY - REFERENCE VALUES AT REST AND DURING HYPERVENTILATION IN HEALTHY-CHILDREN AND ADOLESCENTS IN RELATION TO AGE AND SEX [J].
BROUWERS, PJAM ;
VRIENS, EM ;
MUSBACH, M ;
WIENEKE, GH ;
VANHUFFELEN, AC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (01) :1-8