Determination of Menadione by Liquid Chromatography-Tandem Mass Spectrometry Using Pseudo Multiple Reaction Monitoring

被引:6
作者
Kamao, Maya [1 ]
Hirota, Yoshihisa [2 ]
Suhara, Yoshitomo [3 ]
Tsugawa, Naoko [4 ]
Nakagawa, Kimie [1 ]
Okano, Toshio [1 ]
Hasegawa, Hiroshi [1 ]
机构
[1] Kobe Pharmaceut Univ, Dept Hyg Sci, 4-19-1 Motoyamakita Machi, Kobe, Hyogo 6588558, Japan
[2] Shibaura Inst Technol, Coll Syst Engn & Sci, Dept Biosci & Engn, Lab Biochem, 307 Fukasaku, Minuma, Saitama 3378570, Japan
[3] Shibaura Inst Technol, Coll Syst Engn & Sci, Dept Biosci & Engn, Lab Organ Synth & Med Chem, 307 Fukasaku, Minuma, Saitama 3378570, Japan
[4] Osaka Shoin Womens Univ, Fac Hlth & Nutr, Lab Publ Hlth, 4-2-26 Hishiya Nishi, Higashiosaka, Osaka 5778550, Japan
基金
日本学术振兴会;
关键词
Menadione; vitamin K; pseudo MRM; LC-MS/MS; HUMAN PLASMA; VALPROIC ACID; LC-MS/MS; MENAQUINONE-4; VITAMIN-K-2; PHYLLOQUINONE VITAMIN-K-1; QUANTITATIVE-ANALYSIS; ANTIEPILEPTIC DRUGS; HIGH-THROUGHPUT; METABOLISM; URINE;
D O I
10.2116/analsci.33.863
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study aimed to develop a menadione (MD) determination method employing liquid chromatography-tandem mass spectrometry (LC-MS/MS) using a pseudo multiple reaction monitoring (MRM) technique, wherein two quadrupoles are used to monitor the same ion. Detection limits of 40 and 2 pg were obtained for MD and its deuterium-labeled form, respectively, whereas MD intra- and inter-assay coefficient of variation values were determined as 5.4 - 8.2%, with the corresponding recoveries equaling 90.5 - 109.6%. The developed method enables determination of MD in urine, plasma, cell extract, and culture media, demonstrating that pseudo multiple reaction monitoring can achieve quantification of compounds forming no suitable product ions, such as MD.
引用
收藏
页码:863 / 867
页数:5
相关论文
共 22 条
  • [1] Measurement of menadione in urine by HPLC
    Al Rajabi, Ala
    Peterson, James
    Choi, Sang-Woon
    Suttie, John
    Barakat, Susan
    Booth, Sarah L.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (26): : 2457 - 2460
  • [2] Demirkaya-Miloglu F, 2014, IRAN J PHARM RES, V13, P353
  • [3] MENADIONE-INDUCED CYTO-TOXICITY IS ASSOCIATED WITH PROTEIN THIOL OXIDATION AND ALTERATION IN INTRACELLULAR CA-2+ HOMEOSTASIS
    DIMONTE, D
    BELLOMO, G
    THOR, H
    NICOTERA, P
    ORRENIUS, S
    [J]. ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1984, 235 (02) : 343 - 350
  • [4] Development and Validation of the First Assay Method Coupling Liquid Chromatography with Chemiluminescence for the Simultaneous Determination of Menadione and Its Thioether Conjugates in Rat Plasma
    Elgawish, Mohamed Saleh
    Shimomai, Chikako
    Kishikawa, Naoya
    Ohyama, Kaname
    Wada, Mitsuhiro
    Kuroda, Naotaka
    [J]. CHEMICAL RESEARCH IN TOXICOLOGY, 2013, 26 (09) : 1409 - 1417
  • [5] LC-MS/MS method for simultaneous determination of valproic acid and major metabolites in human plasma
    Gao, Shouhong
    Miao, Haijun
    Tao, Xia
    Jiang, Bo
    Xiao, Ying
    Cai, Fei
    Yun, Yunlei
    Li, Jingxian
    Chen, Wansheng
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (21): : 1939 - 1944
  • [6] Development and characterization of a pseudo multiple reaction monitoring method for the quantification of human uromodulin in urine
    Hammond, Thomas G.
    Moes, Suzette
    Youhanna, Sonia
    Jennings, Paul
    Devuyst, Olivier
    Odermatt, Alex
    Jeno, Paul
    [J]. BIOANALYSIS, 2016, 8 (12) : 1279 - 1296
  • [7] Menadione (Vitamin K3) Is a Catabolic Product of Oral Phylloquinone (Vitamin K1) in the Intestine and a Circulating Precursor of Tissue Menaquinone-4 (Vitamin K2) in Rats
    Hirota, Yoshihisa
    Tsugawa, Naoko
    Nakagawa, Kimie
    Suhara, Yoshitomo
    Tanaka, Kiyoshi
    Uchino, Yuri
    Takeuchi, Atsuko
    Sawada, Natsumi
    Kamao, Maya
    Wada, Akimori
    Okitsu, Takashi
    Okano, Toshio
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 2013, 288 (46) : 33071 - 33080
  • [8] A high throughput and selective method for the estimation of valproic acid an antiepileptic drug in human plasma by tandem LC-MS/MS
    Jain, Deepak S.
    Subbaiah, Gunta
    Sanyal, Mallika
    Shrivastav, Pranav
    [J]. TALANTA, 2007, 72 (01) : 80 - 88
  • [9] Quantitative analysis of low-abundance serological proteins with peptide affinity-based enrichment and pseudo-multiple reaction monitoring by hybrid quadrupole time-of-flight mass spectrometry
    Kim, Kwang Hoe
    Ahn, Yeong Hee
    Ji, Eun Sun
    Lee, Ju Yeon
    Kim, Jin Young
    An, Hyun Joo
    Yoo, Jong Shin
    [J]. ANALYTICA CHIMICA ACTA, 2015, 882 : 38 - 48
  • [10] Simple and accurate quantitative analysis of ten antiepileptic drugs in human plasma by liquid chromatography/tandem mass spectrometry
    Kim, Kwon-Bok
    Seo, Kyung-Ah
    Kim, Sung-Eun
    Bae, Soo Kyung
    Kim, Dong-Hyun
    Shin, Jae-Gook
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (04) : 771 - 777