Evaluation of measures aimed to reduce serious adverse transfusion reactions (hemovigilance data from 1997 to 2008)

被引:0
作者
Funk, M. B. [1 ]
Guenay, S. [1 ]
Lohmann, A. [1 ]
Henseler, O. [1 ]
Keller-Stanislawski, B. [1 ]
机构
[1] Paul Ehrlich Inst, Referat Pharmakovigilanz 2 S2, D-63225 Langen, Germany
关键词
Hemovigilance; Safety standard; Measures; Reduction of serious transfusion reactions; Reporting frequency; HAEMOVIGILANCE SYSTEM; BLOOD; ORGANIZATION; EXPERIENCE; PLATELETS; GERMANY;
D O I
10.1007/s00103-010-1037-8
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
On the basis of reports of serious transfusion reactions, measures aimed to improve the safety standard of the manufacturing process of blood components were evaluated from 1997-2008. Measures of the Paul-Ehrlich-Institut (PEI) as well as recommendations of the Advisory Committee "Blood" were considered. Reporting frequencies before and after the implementation of measures were compared. After the implementation of NAT pool testing, a reduction of virus transmission was seen for red blood cell concentrates (RBC) from 1.0/106 to 0.5/106 units and for platelet concentrates (PC) from 3.0/106 to 0.0/106 units. After the implementation of a pre-donation sampling, however, no reduction of bacterial infections associated with PC administration (> 9.0/106) was identified. To reduce the frequency of TRALI associated with FFP administration (11.2/106 units), the use of plasma from male donors or female donors without a history of pregnancy was established in September 2009. Without specific measures of risk reduction, the reporting frequency of severe allergic transfusion reaction increased for all blood components during the investigation period (from 0.8/106 to 6.2/106 RBC units). The benefit of measures to improve safety standards should be evaluated repeatedly by collecting precise hemovigilance data.
引用
收藏
页码:347 / 356
页数:10
相关论文
共 22 条
[1]   Hemovigilance network in France:: organization and analysis of immediate transfusion incident reports from 1994 to 1998 [J].
Andreu, G ;
Morel, P ;
Forestier, F ;
Debeir, J ;
Rebibo, D ;
Janvier, G ;
Hervé, P .
TRANSFUSION, 2002, 42 (10) :1356-1364
[2]   Recommendations of the ISBT Working Party on Granulocyte Immunobiology for leucocyte antibody screening in the investigation and prevention of antibody-mediated transfusion-related acute lung injury [J].
Bierling, P. ;
Bux, J. ;
Curtis, B. ;
Flesch, B. ;
Fung, I. ;
Lucas, G. ;
Macek, M. ;
Muniz-Diaz, E. ;
Porcelijn, I. ;
Reil, A. ;
Sachs, U. ;
Schuller, R. ;
Tsuno, N. ;
Uhrynowska, M. ;
Urbaniak, S. ;
Valentin, N. ;
Wikman, A. ;
Zupanska, B. .
VOX SANGUINIS, 2009, 96 (03) :266-269
[3]   Transfusion-related acute lung injury (TRALI): a serious adverse event of blood transfusion [J].
Bux, J .
VOX SANGUINIS, 2005, 89 (01) :1-10
[4]   Ten years of hemovigilance reports of transfusion-related acute lung injury in the United Kingdom and the impact of preferential use of male donor plasma [J].
Chapman, Catherine E. ;
Stainsby, Dorothy ;
Jones, Hilary ;
Love, Elizabeth ;
Massey, Edwin ;
Win, Nay ;
Navarrete, Cristina ;
Lucas, Geoff ;
Soni, Neil ;
Morgan, Cliff ;
Choo, Louise ;
Cohen, Hannah ;
Williamson, Lorna M. .
TRANSFUSION, 2009, 49 (03) :440-452
[5]   Bacterial screening of apheresis platelets and the residual risk of septic transfusion reactions: the American Red Cross experience (2004-2006) [J].
Eder, Anne F. ;
Kennedy, Jean M. ;
Dy, Beth A. ;
Notari, Edward P. ;
Weiss, John W. ;
Fang, Chyang T. ;
Wagner, Stephen ;
Dodd, Roger Y. ;
Benjamin, Richard J. .
TRANSFUSION, 2007, 47 (07) :1134-1142
[6]  
*EHN, DEF ADV TRANSF EV
[7]   Hemovigilance in Germany -: Reports to the Paul-Ehrlich-Institut between January 1995 and December 2002 concerning suspected transfusion reactions [J].
Graul, A ;
Heiden, M ;
Gräf, K ;
Keller-Stanislawski, B .
TRANSFUSION MEDICINE AND HEMOTHERAPY, 2003, 30 (05) :232-238
[8]  
GRAUL A, 1999, BUNDESGESUNDHBL, V42, P143
[9]   Will Genotyping Replace Serology in Future Routine Blood Grouping? Opinion 2 [J].
Hustinx, Hein ;
Fontana, Stefano ;
Gowland, Peter ;
Niederhauser, Christoph .
TRANSFUSION MEDICINE AND HEMOTHERAPY, 2009, 36 (03) :228-229
[10]   The German Haemovigilance System-reports of serious adverse transfusion reactions between 1997 and 2007 [J].
Keller-Stanislawski, B. ;
Lohmann, A. ;
Guenay, S. ;
Heiden, M. ;
Funk, M. B. .
TRANSFUSION MEDICINE, 2009, 19 (06) :340-349