Aerosol Delivery of DNA/Liposomes to the Lung for Cystic Fibrosis Gene Therapy

被引:46
作者
Davies, Lee A. [1 ,2 ]
Nunez-Alonso, Graciela A. [1 ,2 ]
McLachlan, Gerry [2 ,3 ,4 ]
Hyde, Stephen C. [1 ,2 ]
Gill, Deborah R. [1 ,2 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, Nuffield Div Clin Lab Sci, Gene Med Res Grp, Oxford OX3 9DU, England
[2] United Kingdom Cyst Fibrosis Gene Therapy Consort, London, England
[3] Univ Edinburgh, Roslin Inst, Roslin EH25 9RG, Midlothian, Scotland
[4] Univ Edinburgh, RDSVS, Roslin EH25 9RG, Midlothian, Scotland
关键词
CPG-FREE PLASMIDS; DNA COMPLEXES; PHYSICOCHEMICAL PROPERTIES; DOUBLE-BLIND; EXPRESSION; OPTIMIZATION; IMPACTOR; VECTOR; JET;
D O I
10.1089/humc.2014.019
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Lung gene therapy is being evaluated for a range of acute and chronic diseases, including cystic fibrosis (CF). As these therapies approach clinical realization, it is becoming increasingly clear that the ability to efficiently deliver gene transfer agents (GTAs) to target cell populations within the lung may prove just as critical as the gene therapy formulation itself in terms of generating positive clinical outcomes. Key to the success of any aerosol gene therapy is the interaction between the GTA and nebulization device. We evaluated the effects of aerosolization on our preferred formulation, plasmid DNA (pDNA) complexed with the cationic liposome GL67A (pDNA/GL67A) using commercially available nebulizer devices. The relatively high viscosity (6.3 +/- 0.1 cP) and particulate nature of pDNA/GL67A formulations hindered stable aerosol generation in ultrasonic and vibrating mesh nebulizers but was not problematic in the jet nebulizers tested. Aerosol size characteristics varied significantly between devices, but the AeroEclipse II nebulizer operating at 50 psi generated stable pDNA/GL67A aerosols suitable for delivery to the CF lung (mass median aerodynamic diameter 3.4 +/- 0.1 mu m). Importantly, biological function of pDNA/GL67A formulations was retained after nebulization, and although aerosol delivery rate was lower than that of other devices (0.17 +/- 0.01 ml/min), the breath-actuated AeroEclipse II nebulizer generated aerosol only during the inspiratory phase and as such was more efficient than other devices with 83 +/- 3% of generated aerosol available for patient inhalation. On the basis of these results, we have selected the AeroEclipse II nebulizer for the delivery of pDNA/GL67A formulations to the lungs of CF patients as part of phase IIa/b clinical studies.
引用
收藏
页码:97 / 107
页数:11
相关论文
共 37 条
[1]   Toxicology study assessing efficacy and safety of repeated administration of lipid/DNA complexes to mouse lung [J].
Alton, E. W. F. W. ;
Boyd, A. C. ;
Cheng, S. H. ;
Davies, J. C. ;
Davies, L. A. ;
Dayan, A. ;
Gill, D. R. ;
Griesenbach, U. ;
Higgins, T. ;
Hyde, S. C. ;
Innes, J. A. ;
McLachlan, G. ;
Porteous, D. ;
Pringle, I. ;
Scheule, R. K. ;
Sumner-Jones, S. .
GENE THERAPY, 2014, 21 (01) :89-95
[2]   A randomised, double-blind, placebo-controlled phase IIB clinical trial of repeated application of gene therapy in patients with cystic fibrosis [J].
Alton, Eric W. F. W. ;
Boyd, A. Christopher ;
Cheng, Seng H. ;
Cunningham, Steve ;
Davies, Jane C. ;
Gill, Deborah R. ;
Griesenbach, Uta ;
Higgins, Tracy ;
Hyde, Stephen C. ;
Innes, J. Alastair ;
Murray, Gordon D. ;
Porteous, David J. .
THORAX, 2013, 68 (11) :1075-1077
[3]   Cationic lipid-mediated CFTR gene transfer to the lungs and nose of patients with cystic fibrosis:: a double-blind placebo-controlled trial [J].
Alton, EWFW ;
Stern, M ;
Farley, R ;
Jaffe, A ;
Chadwick, SL ;
Phillips, J ;
Davies, J ;
Smith, SN ;
Browning, J ;
Davies, MG ;
Hodson, ME ;
Durham, SR ;
Li, D ;
Jeffery, PK ;
Scallan, M ;
Balfour, R ;
Eastman, SJ ;
Cheng, SH ;
Smith, AE ;
Meeker, D ;
Geddes, DM .
LANCET, 1999, 353 (9157) :947-954
[4]   Studies on aerosol delivery of plasmid DNA using a mesh Nebulizer [J].
Arulmuthu, Eugene R. ;
Williams, David J. ;
Baldascini, Helen ;
Versteeg, Henk K. ;
Hoare, Mike .
BIOTECHNOLOGY AND BIOENGINEERING, 2007, 98 (05) :939-955
[5]   Determination of nebulizer droplet size distribution: A method based on impactor refrigeration [J].
Berg, Elna ;
Svensson, Jan Olof ;
Asking, Lars .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2007, 20 (02) :97-104
[6]   Electrohydrodynamic comminution: A novel technique for the aerosolisation of plasmid DNA [J].
Davies, LA ;
Hannavy, K ;
Davies, N ;
Pirrie, A ;
Coffee, RA ;
Hyde, SC ;
Gill, DR .
PHARMACEUTICAL RESEARCH, 2005, 22 (08) :1294-1304
[7]   Enhanced lung gene expression after aerosol delivery of concentrated pDNA/PEI complexes [J].
Davies, Lee A. ;
McLachlan, Gerry ;
Sumner-Jones, Stephanie G. ;
Ferguson, David ;
Baker, Alison ;
Tennant, Peter ;
Gordon, Catherine ;
Vrettou, Christina ;
Baker, Eilidh ;
Zhu, Jie ;
Alton, Eric W. F. W. ;
Collie, David D. S. ;
Porteous, David J. ;
Hyde, Stephen C. ;
Gill, Deborah R. .
MOLECULAR THERAPY, 2008, 16 (07) :1283-1290
[8]   The use of CpG-free plasmids to mediate persistent gene expression following repeated aerosol delivery of pDNA/PEI complexes [J].
Davies, Lee A. ;
Hyde, Stephen C. ;
Nunez-Alonso, Graciela ;
Bazzani, Reto P. ;
Harding-Smith, Rebekka ;
Pringle, Ian A. ;
Lawton, Anna E. ;
Abdullah, Syahril ;
Roberts, Thomas C. ;
McCormick, Dominique ;
Sumner-Jones, Stephanie G. ;
Gill, Deborah R. .
BIOMATERIALS, 2012, 33 (22) :5618-5627
[9]   DRUG NEBULIZER DESIGN AND PERFORMANCE - BREATH ENHANCED JET VS CONSTANT OUTPUT JET VS ULTRASONIC [J].
DENNIS, JH .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1995, 8 (03) :277-280
[10]   Aerosol delivery of robust polyethyleneimine-DNA complexes for gene therapy and genetic immunization [J].
Densmore, CL ;
Orson, FM ;
Xu, B ;
Kinsey, BM ;
Waldrep, JC ;
Hua, P ;
Bhogal, B ;
Knight, V .
MOLECULAR THERAPY, 2000, 1 (02) :180-188