Highly sensitive and selective amperometric sensors for nanomolar detection of iodate and periodate based on glassy carbon electrode modified with iridium oxide nanoparticles

被引:28
|
作者
Salimi, Abdollah [1 ,2 ]
Hallaj, Rahman [1 ]
Kavosi, Begard [1 ]
Hagighi, Behzad [3 ]
机构
[1] Univ Kurdistan, Dept Chem, Sanandaj, Iran
[2] Univ Kurdistan, Res Ctr Nanotechnol, Sanandaj, Iran
[3] Inst Adv Studies Basic Sci, Dept Chem, Gava Zang, Zanjan, Iran
关键词
Iridium oxide; Nanoparticles; Iodate; Periodate; Flow injection analysis; Amperometry; ULTRA-TRACE AMOUNTS; FABRICATION; REDUCTION; BROMATE; DEPOSITION;
D O I
10.1016/j.aca.2009.12.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Iridium oxide nanoparticles are grown on a glassy carbon electrode by electrode positing method. The electrochemical behavior and electrocatalytic activity of modified electrode towards reduction of iodate and periodate are studied. The reductions of both ions occur at the unusual positive peak potential of 0.7 V vs. reference electrode. The modified electrode is employed successfully for iodate and periodates detection using cyclic voltammetry, hydrodynamic amperometry and flow injection analysis (FIA). In the performed experiments, flow injection amperometric determination of iodate and periodate yielded calibration curves with the following characteristics: linear dynamic range up to 100 and 80 mu M, sensitivity of 140.9 and 150.6 nA mu M-1 and detection limits of 5 and 36nM, respectively. The repeatability of the modified electrode for 21 injections of 1.5 mu M of iodate solution is 1.5%. The interference effects of NO2-, NO3-, ClO3-, BrO3-. ClO4-. SO42-. Cu2+, Zn2+, Mn2+, Mg2+, Cd2+, Ca2+, Na+, K+, NH4+ and K+, CH3COO- and glucose were negligible at the concentration ratio of more than 1000. The obtained attractive analytical performance together with high selectivity and simplicity of the proposed method provide an effective and a novel modified electrode to develop an iodate and periodate sensor. Sensitivity, selectivity, the liner concentration range and the detection limit of the developed sensor are all much better than all known similar sensors in the literature for iodate and periodate determination. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 50 条
  • [41] Amperometric detection of morphine at preheated glassy carbon electrode modified with multiwall carbon nanotubes
    Salimi, A
    Hallaj, R
    Khayatian, GR
    ELECTROANALYSIS, 2005, 17 (10) : 873 - 879
  • [42] Eutectic mixture-functionalized carbon nanomaterials for selective amperometric detection of nitrite using modified glassy carbon electrode
    Abo-Hamad, Ali
    AlSaadi, Mohammed AbdulHakim
    Hashim, Mohd Ali
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 812 : 107 - 114
  • [43] Photoelectrochemical amperometric sensing of cyanide using a glassy carbon electrode modified with graphene oxide and titanium dioxide nanoparticles
    Rahman Hallaj
    Nasibeh Haghighi
    Microchimica Acta, 2017, 184 : 3581 - 3590
  • [44] Photoelectrochemical amperometric sensing of cyanide using a glassy carbon electrode modified with graphene oxide and titanium dioxide nanoparticles
    Hallaj, Rahman
    Haghighi, Nasibeh
    MICROCHIMICA ACTA, 2017, 184 (09) : 3581 - 3590
  • [45] Voltammetric and amperometric determination of iodate using a modified glassy carbon electrode based on PW12/MOF/P@ERGO nanohybrid
    Ravanbakhsh, Hamid
    Dianat, Somayeh
    SENSING AND BIO-SENSING RESEARCH, 2023, 40
  • [46] Selective and Sensitive Nitrite Sensor Based on Glassy Carbon Electrode Modified by Silver Nanochains
    Shaikh, Tayyaba
    Ibupoto, Zaffar Hussain
    Talpur, Farah N.
    Sirajuddin
    Khaskheli, Abdul Rauf
    Agheem, Muhammad H.
    Siddiqui, Samia
    Tahira, Aneela
    Willander, Magnus
    Yu, Cong
    ELECTROANALYSIS, 2017, 29 (02) : 415 - 422
  • [47] A cobalt oxide nanocubes interleaved reduced graphene oxide nanocomposite modified glassy carbon electrode for amperometric detection of serotonin
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Numan, Arshid
    Shahabuddin, Syed
    Alizadeh, Mandi
    Khiew, Poi Sim
    Chiu, Wee Siong
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 100 : 388 - 395
  • [48] A Highly Sensitive Amperometric Glucose Biosensor Based on a Nano-cube Cu2O Modified Glassy Carbon Electrode
    Ma Zhen-Zhen
    Yu Hui-Cheng
    Wu Zhao-Yang
    Wu Yan
    Xiao Fu-Bing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (05) : 822 - 826
  • [49] Amperometric NADH Biosensor Based on Magnetic Chitosan Microspheres/Poly(thionine) Modified Glassy Carbon Electrode
    Liu, Ya
    Zhang, Hai-Li
    Lai, Guo-Song
    Yu, Ai-Min
    Huang, Yu-Mei
    Han, De-Yan
    ELECTROANALYSIS, 2010, 22 (15) : 1725 - 1732
  • [50] Highly sensitive amperometric detection of bilirubin using enzyme and gold nanoparticles on sol-gel film modified electrode
    Kannan, Palanisamy
    Chen, Hailan
    Lee, Victor Tswen-Wen
    Kim, Dong-Hwan
    TALANTA, 2011, 86 : 400 - 407