Influence of steep Trendelenburg position and CO2 pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during robotic prostatectomy

被引:159
|
作者
Kalmar, A. F. [1 ]
Foubert, L. [2 ]
Hendrickx, J. F. A. [2 ]
Mottrie, A. [3 ]
Absalom, A. [1 ]
Mortier, E. P. [4 ]
Struys, M. M. R. F. [1 ,4 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Anesthesiol, Groningen, Netherlands
[2] OLV Clin, Dept Anaesthesia & Intens Care Med, Aalst, Belgium
[3] OLV Clin, Dept Urol, Aalst, Belgium
[4] Univ Ghent, Dept Anesthesia, B-9000 Ghent, Belgium
关键词
brain; blood flow; intracranial pressure; lung compliance; position; Trendelenburg; surgery; urological; RADICAL PROSTATECTOMY; PRESSURE; INSUFFLATION; SURGERY;
D O I
10.1093/bja/aeq018
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The steep (40 degrees) Trendelenburg position optimizes surgical exposure during robotic prostatectomy. The goal of the current study was to investigate the combined effect of this position and CO2 pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during these procedures. Physiological data were recorded during the whole surgical procedure in 31 consecutive patients who underwent robotic endoscopic radical prostatectomy under general anaesthesia. Heart rate, mean arterial pressure, central venous pressure, Sp(o2), Pe'(co2), P-Plat, tidal volume, compliance, and minute ventilation were monitored and recorded. Arterial samples were obtained to determine the arterial-to-end-tidal CO2 tension gradient. Continuous regional cerebral tissue oxygen saturation (Sct(o2)) was determined by near-infrared spectroscopy. Although patients were in the Trendelenburg position, all variables investigated remained within a clinically acceptable range. Cerebral perfusion pressure (CPP) decreased from 77 mm Hg at baseline to 71 mm Hg (P=0.07), and Sct(o2) increased from 70% to 73% (P < 0.001). Pe'(co2) increased from 4.12 to 4.79 kPa (P < 0.001) and the arterial-to-Pe'(co2) tension difference increased from 1.06 kPa in the normal position to a maximum of 1.41 kPa (P < 0.001) after 2 h in the Trendelenburg position. The combination of the prolonged steep Trendelenburg position and CO2 pneumoperitoneum was well tolerated. Haemodynamic and pulmonary variables remained within safe limits. Regional cerebral oxygenation was well preserved and CPP remained within the limits between which cerebral blood flow is usually considered to be maintained by cerebral autoregulation.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 6 条
  • [1] Cerebral haemodynamic physiology during steep Trendelenburg position and CO2 pneumoperitoneum
    Kalmar, A. F.
    Dewaele, F.
    Foubert, L.
    Hendrickx, J. F.
    Heeremans, E. H.
    Struys, M. M. R. F.
    Absalom, A.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (03) : 478 - 484
  • [2] A comparative analysis of the effects of sevoflurane and propofol on cerebral oxygenation during steep Trendelenburg position and pneumoperitoneum for robotic-assisted laparoscopic prostatectomy
    Doe, Aya
    Kumagai, Motoi
    Tamura, Yuichiro
    Sakai, Akira
    Suzuki, Kenji
    JOURNAL OF ANESTHESIA, 2016, 30 (06) : 949 - 955
  • [3] Effects of pneumoperitoneum and steep Trendelenburg position on cerebral hemodynamics during robotic-assisted laparoscopic radical prostatectomy A randomized controlled study
    Chen, Ke
    Wang, Lizhen
    Wang, Qing
    Liu, Xuesheng
    Lu, Yao
    Li, Yuanhai
    Wong, Gordon Tin Chun
    MEDICINE, 2019, 98 (21)
  • [4] Haemodynamics and cardiac function during robotic-assisted laparoscopic prostatectomy in steep Trendelenburg position
    Haas, Sebastian
    Haese, Alexander
    Goetz, Alwin E.
    Kubitz, Jens C.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2011, 7 (04) : 408 - 413
  • [5] Effects of Pneumoperitoneum and the Steep Trendelenburg Position on Heart Rate Variability and Cerebral Oxygenation during Robotic Sacrocolpopexy
    Matanes, Emad
    Weissman, Amir
    Rivlin, Aleksandr
    Lauterbach, Roy
    Amit, Amnon
    Wiener, Zeev
    Lowenstein, Lior
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2018, 25 (01) : 70 - 75
  • [6] Effect of pneumoperitoneum and Trendelenburg position on internal carotid artery blood flow measured by ultrasound during robotic prostatectomy
    Yu, Jihion
    Park, Jun-Young
    Hong, Jun Hyuk
    Hwang, Jai-Hyun
    Kim, Young-Kug
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2022, 42 (02) : 139 - 145