Axial behaviour of semi-lightweight aggregate concrete-filled steel tube columns - A DOE approach

被引:18
作者
Abhilash, M. [1 ]
Jhanjhari, Sanyam [1 ]
Parthiban, P. [1 ]
Karthikeyan, J. [1 ]
机构
[1] Natl Inst Technol, Dept Civil Engn, Tiruchirappalli, Tamil Nadu, India
关键词
Concrete-filled steel tube columns; Calcite powder pellets; Semi-lightweight aggregate concrete; 2(k) factorial design; Analysis of variance; Regression analysis; OF-THE-ART; TUBULAR COLUMNS; STRENGTH; DESIGN;
D O I
10.1016/j.jcsr.2019.05.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The main purpose of this paper is to present the experimental investigation on the axial behaviour of concrete-filled steel tube columns using semi-lightweight aggregate concrete as an infill type. The paper describes the effect of variation in the diameter (D), width (B), thickness (t) and length-to-diameter (L/D) ratio of steel tube with a special type of core concrete on the ultimate axial load (N-ue) and the associated axial shortening (delta(ue)) for both the circular and the square CFST columns. The experimental campaign involves, finding the mechanical properties of steel, concrete and the Axial compression tests conducted on the CFST specimens. The 2(k) factorial design; a DOE approach is implemented primarily. Subsequently ANOVA, a statistical tool is used to analyze and compare the different combinations for reducing the error variance and finding the most influential factor on N-ue and delta(ue), Basic prediction models are proposed to predict the response N-ue and delta(ue) for the CFST columns and further, the Response surface method is implemented to revise the models for interaction between the different combinations. Comparisons are made with the existing design codes like ANSI/AISC 360-10 and EN-1994 (Eurocode 4) to validate. The proposed model predictions thus, validate the experimental results with good accuracy. The tests confirmed the considerable influence of semi-lightweight aggregate concrete on the performance of CFST columns. In addition, the confinement improves the strength of the infill concrete and thus validates the use of semi-lightweight aggregate concrete as an infill to the CFST columns for structural purpose and particularly for reduced self-weight, (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:16
相关论文
共 29 条
[1]  
ACI, 2019, 318M11 ACI
[2]  
AISC, 2019, 36010 ANSIAISC
[3]  
[Anonymous], 2001, SYNOPSIS STUDIES MON
[4]  
[Anonymous], DESIGN ANAL EXPT
[5]   Ultimate moment capacity of foamed and lightweight aggregate concrete-filled steel tubes [J].
Assi, IM ;
Qudeimat, EM ;
Hunaiti, YM .
STEEL AND COMPOSITE STRUCTURES, 2003, 3 (03) :199-212
[6]   Behavior and strength of partially encased composite columns with built-up shapes [J].
Chicoine, T ;
Tremblay, R ;
Massicotte, B ;
Ricles, JM ;
Lu, LW .
JOURNAL OF STRUCTURAL ENGINEERING, 2002, 128 (03) :279-288
[7]   Behavior of rectangular concrete-filled high-strength steel tubular columns with different aspect ratio [J].
Du, Yansheng ;
Chen, Zhihua ;
Yu, Yujie .
THIN-WALLED STRUCTURES, 2016, 109 :304-318
[8]   Experimental behavior and design method of rectangular concrete-filled tubular columns using Q460 high-strength steel [J].
Du, Yansheng ;
Chen, Zhihua ;
Xiong, Ming-Xiang .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 125 :856-872
[9]  
EN, 2019, 199411 EN BRIT STAND
[10]  
Fu Z.Q., 2011, GeoHunan International Conference 2011, P24