Prosthesis-Patient Mismatch After Aortic Valve Replacement in the PARTNER 2 Trial and Registry

被引:68
|
作者
Ternacle, Julien [1 ]
Pibarot, Philippe [1 ]
Herrmann, Howard C. [2 ]
Kodali, Susheel [3 ]
Leipsic, Jonathon [4 ]
Blanke, Philipp [4 ]
Jaber, Wael [5 ]
Mack, Michael J. [6 ]
Clavel, Marie-Annick [1 ]
Salaun, Erwan [1 ]
Guzzetti, Ezequiel [1 ]
Annabi, Mohamed-Salah [1 ]
Bernier, Mathieu [1 ]
Beaudoin, Jonathan [1 ]
Khalique, Omar K. [3 ]
Weissman, Neil J. [7 ]
Douglas, Pamela [8 ]
Bax, Jeroen [9 ]
Dahou, Abdellaziz [10 ]
Xu, Ke [11 ]
Alu, Maria [3 ,10 ]
Rogers, Erin [11 ]
Leon, Martin [3 ,10 ]
Thourani, Vinod H. [12 ]
Abbas, Amr E. [13 ,14 ]
Hahn, Rebecca T. [3 ,10 ]
机构
[1] Univ Laval, Quebec Heart & Lung Inst, Quebec City, PQ, Canada
[2] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Columbia Univ, Med Ctr, NewYork Presbyterian Hosp, New York, NY USA
[4] Univ British Columbia, St Pauls Hosp, Vancouver, BC, Canada
[5] Cleveland Clin, Cleveland, OH 44106 USA
[6] Baylor Scott & White Healthcare, Plano, TX USA
[7] Georgetown Univ, MedStar Heath Res Inst, Washington, DC USA
[8] Duke Univ, Duke Clin Res Inst, Med Ctr, Durham, NC USA
[9] Leiden Univ, Dept Cardiol, Med Ctr, Leiden, Netherlands
[10] Cardiovasc Res Fdn, New York, NY USA
[11] Edwards Lifesci, Irvine, CA USA
[12] Marcus Valve Ctr, Piedmont Heart Inst, Dept Cardiovasc Surg, Atlanta, GA USA
[13] Oakland Univ, William Beaumont Sch Med, Auburn Hills, MI USA
[14] Beaumont Hosp Royal Oak, Royal Oak, MI USA
关键词
aortic stenosis; effective orifice area; prosthetic heart valve; prosthesis-patient mismatch; transcatheter aortic valve replacement; transvalvular pressure gradient; INTERMEDIATE-RISK PATIENTS; END-POINT DEFINITIONS; LONG-TERM SURVIVAL; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; TRANSCATHETER; OUTCOMES; IMPACT; IMPLANTATION; STENOSIS;
D O I
10.1016/j.jcin.2021.03.069
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). BACKGROUND TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series. METHODS The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi <= 0.85 cm(2)/m2 (<= 0.70 if obese: body mass index >= 30 kg/m(2)) and severe if EOAi <= 0.65 cm(2)/m(2) (<= 0.55 if obese). PPMM was determined by the core lab-measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization. RESULTS The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR. CONCLUSIONS EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR. (C) 2021 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:1466 / 1477
页数:12
相关论文
共 50 条
  • [31] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Levesque, Thomas
    Eltchaninoff, Helene
    Chabannes, Romain
    Barbe, Thomas
    Dosseh, Olivier
    Tron, Christophe
    Bettinger, Nicolas
    Bouhzam, Najime
    Hemery, Thibaut
    le Pessec, Guillaume
    Fauvel, Charles
    Cribier, Alain
    Pibarot, Philippe
    Durand, Eric
    CANADIAN JOURNAL OF CARDIOLOGY, 2024, 40 (01) : 113 - 122
  • [32] Prosthesis-Patient Mismatch After Aortic Valve Replacement: Is It Time for a Redefinition?
    Mannacio, Vito
    De Amicis, Vincenzo
    Vosa, Carlo
    ANNALS OF THORACIC SURGERY, 2014, 97 (04): : 1482 - 1482
  • [33] Incidence and Prognosis of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement for Bicuspid Aortic Stenosis
    Yamanaka, Futoshi
    Shishido, Koki
    Moriyama, Noriaki
    Ochiai, Tomoki
    Miyashita, Hirokazu
    Yokoyama, Hiroaki
    Sugiyama, Yoichi
    Yashima, Fumiaki
    Ohno, Yohei
    Nishina, Hidetaka
    Izumo, Masaki
    Asami, Masahiko
    Naganuma, Toru
    Mizutani, Kazuki
    Yamawaki, Masahiro
    Tada, Norio
    Shirai, Shinichi
    Noguchi, Masahiko
    Ueno, Hiroshi
    Takagi, Kensuke
    Watanabe, Yusuke
    Yamamoto, Masanori
    Saito, Shigeru
    Hayashida, Kentaro
    JACC-CARDIOVASCULAR INTERVENTIONS, 2025, 18 (04) : 492 - 502
  • [34] Impact of Pre-Existing Prosthesis-Patient Mismatch on Survival Following Aortic Valve-in-Valve Procedures
    Pibarot, Philippe
    Simonato, Matheus
    Barbanti, Marco
    Linke, Axel
    Kornowski, Ran
    Rudolph, Tanja
    Spence, Mark
    Moat, Neil
    Aldea, Gabriel
    Mennuni, Marco
    Iadanza, Alessandro
    Amrane, Hafid
    Gaia, Diego
    Kim, Won-Keun
    Napodano, Massimo
    Baumbach, Hardy
    Finkelstein, Ariel
    Kobayashi, Junjiro
    Brecker, Stephen
    Don, Creighton
    Cerillo, Alfredo
    Unbehaun, Axel
    Attias, David
    Nejjari, Mohammed
    Jones, Noah
    Fiorina, Claudia
    Tchetche, Didier
    Philippart, Raphael
    Spargias, Konstantinos
    Hernandez, Jose-Maria
    Latib, Azeem
    Dvir, Danny
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (02) : 133 - 141
  • [35] Impact of Valve Size on Prosthesis-Patient Mismatch and Aortic Valve Gradient After Transcatheter versus Surgical Aortic Valve Replacement
    Aalaei-Andabili, Seyed Hossein
    Lee, Teng C.
    Waheed, Nida
    Bavry, Anthony A.
    Petersen, John W.
    Wayangankar, Siddharth
    Arnaoutakis, George J.
    Anderson, R. David
    Beaver, Thomas M.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2019, 14 (03) : 243 - 250
  • [36] Surgical versus transcatheter aortic valve replacement: Impact of patient-prosthesis mismatch on outcomes
    Alnajar, Ahmed
    Hamad, Naser
    Azhar, Muhammad Z.
    Mousa, Yaseen
    Arora, Yingyot
    Lamelas, Joseph
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 5388 - 5394
  • [37] Racial Differences in the Incidence and Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Park, Hanbit
    Ahn, Jung-Min
    Kang, Do-Yoon
    Kim, Juyong Brian
    Yeung, Alan C.
    Nishi, Takeshi
    Fearon, William F.
    Cantey, Eric Page
    Flaherty, James D.
    Davidson, Charles J.
    Malaisrie, S. Christopher
    Kim, Sehee
    Yun, Sung-Cheol
    Ko, Euihong
    Lee, Seung-Ah
    Kim, Dae-Hee
    Kim, Ho Jin
    Kim, Joon Bum
    Choo, Suk Jung
    Park, Duk-Woo
    Park, Seung-Jung
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (24) : 2670 - 2681
  • [38] Impact of prosthesis-patient mismatch on early haemodynamic status after aortic valve replacement
    Kindo, Michel
    Minh, Tam Hoang
    Perrier, Stephanie
    Petit-Eisenmann, Helene
    Bentz, Jonathan
    Cristinar, Mircea
    Ajob, Gharib
    Collange, Olivier
    Mazzucotelli, Jean-Philippe
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (01) : 48 - 54
  • [39] Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation
    Morita, Shigeki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2016, 64 (08) : 435 - 440
  • [40] Prosthesis-patient mismatch defined by cardiac computed tomography versus echocardiography after transcatheter aortic valve replacement
    Fukui, Miho
    Garcia, Santiago
    Lesser, John R.
    Gossl, Mario
    Tang, Liang
    Caye, David
    Newell, Marc
    Hashimoto, Go
    Lopes, Bernardo B. C.
    Stanberry, Larissa, I
    Enriquez-Sarano, Maurice
    Pibarot, Philippe
    Hahn, RebeccaT
    Sorajja, Paul
    Cavalcante, Joao L.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (05) : 403 - 411