Mechanical behavior of human morselized cancellous bone in triaxial compression testing

被引:56
|
作者
Brodt, MD
Swan, CC
Brown, TD
机构
[1] Univ Iowa, Orthopaed Biomech Lab, Dept Orthopaed Surg, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Mech Engn, Iowa City, IA 52242 USA
[4] Univ Iowa, Dept Civil & Environm Engn, Iowa City, IA 52242 USA
关键词
D O I
10.1002/jor.1100160108
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Despite its widespread use as graft material in orthopaedic surgical procedures, morselized cancellous bone has not yet been well characterized from the standpoint of its mechanical properties. To accommodate the noncohesive nature of this loose particulate form of bone, a triaxial compression test apparatus commonly used in engineering soil mechanics was adapted for the testing of fresh-frozen human morselized cancellous bone specimens. Triaxial compression tests were run to 30% axial strain at five different levels of confining pressure ranging from 0.276 to 8.552 MPa. The measured axial stress versus axial strain behavior was bimodal, characterized initially by relatively stiff linear behavior, then by a rapid transition to a much more compliant (but, again, approximately linear) domain until test cessation. The apparent axial moduli of both response regions were found to be nearly linear functions of the transverse confining pressure. As typically prepared surgically, the distribution of particle size was found to have approximately 80% of the bone graft, by weight, encompassed in particles 0.43-3.2 mm in size. Triaxial tests of samples segregated by size showed that particle size had no appreciable effect on apparent material properties. The nominal Young's modulus and Poisson's ratio of morselized cancellous bone were 100 MPa and 0.2, respectively.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 50 条
  • [31] MECHANICAL PROPERTY DISTRIBUTIONS IN THE CANCELLOUS BONE OF THE HUMAN PROXIMAL FEMUR
    BROWN, TD
    FERGUSON, AB
    ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (03): : 429 - 437
  • [32] Experimental investigation of the anisotropic mechanical behavior of phyllite under triaxial compression
    Xu, Guowen
    He, Chuan
    Su, Ang
    Chen, Ziquan
    INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2018, 104 : 100 - 112
  • [33] Experimental Study on the Mechanical Behavior of Coal under Triaxial Dynamic Compression
    Cheng, Chunhui
    Xue, Sheng
    Han, Yidan
    MINERALS, 2022, 12 (10)
  • [34] Mechanical properties of cancellous bone in the human mandibular condyle are anisotropic
    Giesen, EBW
    Ding, M
    Dalstra, M
    van Eijden, TMGJ
    JOURNAL OF BIOMECHANICS, 2001, 34 (06) : 799 - 803
  • [35] Structural and material mechanical properties of human vertebral cancellous bone
    Nicholson, PHF
    Cheng, XG
    Lowet, G
    Boonen, S
    Davie, MWJ
    Dequeker, J
    Van der Perre, G
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (08) : 729 - 737
  • [36] SYNOPTIC VIEW OF MECHANICAL-BEHAVIOR OF ROCKS UNDER TRIAXIAL COMPRESSION
    GUSTKIEWICZ, J
    ROCK AT GREAT DEPTH, VOL 1: ROCK MECHANICS AND ROCK PHYSICS AT GREAT DEPTH, 1989, : 3 - 10
  • [37] EFFECT OF PASTEURIZATION ON THE MECHANICAL-PROPERTIES OF HUMAN CANCELLOUS BONE
    EASTLUND, T
    ZIMMERMAN, R
    BECHTOLD, J
    TRANSFUSION, 1993, 33 (07) : 615 - 616
  • [38] Recycled aggregate concrete - Mechanical behavior under uniaxial and triaxial compression
    Folino, Paula
    Xargay, Hernan
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 56 : 21 - 31
  • [39] Bone stiffness predicts strength similarly for human vertebral cancellous bone in compression and for cortical bone in tension
    Fyhrie, DP
    Vashishth, D
    BONE, 2000, 26 (02) : 169 - 173
  • [40] Influence of Water Saturation and Real-Time Testing Temperature on Mechanical Behavior of Sandstone Under Conventional Triaxial Compression
    Yang, Sheng-Qi
    Huang, Yan-Hua
    Tian, Wen-Ling
    ROCK MECHANICS AND ROCK ENGINEERING, 2021, 54 (08) : 4355 - 4367