Mechanical behavior of human morselized cancellous bone in triaxial compression testing

被引:56
|
作者
Brodt, MD
Swan, CC
Brown, TD
机构
[1] Univ Iowa, Orthopaed Biomech Lab, Dept Orthopaed Surg, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Mech Engn, Iowa City, IA 52242 USA
[4] Univ Iowa, Dept Civil & Environm Engn, Iowa City, IA 52242 USA
关键词
D O I
10.1002/jor.1100160108
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Despite its widespread use as graft material in orthopaedic surgical procedures, morselized cancellous bone has not yet been well characterized from the standpoint of its mechanical properties. To accommodate the noncohesive nature of this loose particulate form of bone, a triaxial compression test apparatus commonly used in engineering soil mechanics was adapted for the testing of fresh-frozen human morselized cancellous bone specimens. Triaxial compression tests were run to 30% axial strain at five different levels of confining pressure ranging from 0.276 to 8.552 MPa. The measured axial stress versus axial strain behavior was bimodal, characterized initially by relatively stiff linear behavior, then by a rapid transition to a much more compliant (but, again, approximately linear) domain until test cessation. The apparent axial moduli of both response regions were found to be nearly linear functions of the transverse confining pressure. As typically prepared surgically, the distribution of particle size was found to have approximately 80% of the bone graft, by weight, encompassed in particles 0.43-3.2 mm in size. Triaxial tests of samples segregated by size showed that particle size had no appreciable effect on apparent material properties. The nominal Young's modulus and Poisson's ratio of morselized cancellous bone were 100 MPa and 0.2, respectively.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 50 条
  • [21] Experimental study of the mechanical behavior of plastic concrete in triaxial compression
    Mahboubi, A
    Ajorloo, A
    CEMENT AND CONCRETE RESEARCH, 2005, 35 (02) : 412 - 419
  • [22] Cavitary acetabular defects treated with morselized cancellous bone graft and cementless cups
    G. C. T. Pereira
    E. N. Kubiak
    B. Levine
    F. S. Chen
    P. E. Di Cesare
    International Orthopaedics, 2007, 31 : 445 - 450
  • [23] TESTING OF CONCRETE IN TRIAXIAL COMPRESSION
    SOLOMENT.GG
    INDUSTRIAL LABORATORY, 1967, 33 (04): : 590 - &
  • [24] Mechanical triaxial compression machines
    Fedorova E.A.
    Journal of Mining Science, 2008, 44 (04) : 421 - 428
  • [25] Adsorption and release of antibiotics from morselized cancellous bone - In vitro studies of 8 antibiotics
    Witso, E
    Persen, L
    Loseth, K
    Bergh, K
    ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (03): : 298 - 304
  • [26] Mechanical Behaviour of Cancellous Bone: Compression and Three-Point Bending Test
    Ghazali, Farah Amira Mohd
    Syahrom, Ardiyansyah
    MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2022, 18 (03): : 295 - 303
  • [27] Anatomical variation of human cancellous bone mechanical properties in vitro
    Hobatho, MC
    Rho, JY
    Ashman, RB
    BONE RESEARCH IN BIOMECHANICS, 1997, 40 : 157 - 173
  • [28] Mechanical properties of cancellous bone in the human mandibular condyle are anisotropic
    Wang, SJ
    JOURNAL OF BIOMECHANICS, 2002, 35 (04) : 549 - 549
  • [29] Experimental Study on Macroscopic Mechanical Behavior of SFRC under Triaxial Compression
    Wang, Z. L.
    Zhu, H. H.
    Wang, J. G.
    Zhu, B.
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2012, 19 (08) : 653 - 662
  • [30] Laboratory investigation on mechanical behavior of artificial ice under triaxial compression
    Xu, Xiangtian
    Yuan, Junhong
    Bai, Ruiqiang
    ADVANCES IN MATERIALS AND MATERIALS PROCESSING IV, PTS 1 AND 2, 2014, 887-888 : 903 - 906