Compressed Sensing in Hyperpolarized 3He Lung MRI

被引:54
作者
Ajraoui, Salma [1 ]
Lee, Kuan J. [1 ]
Deppe, Martin H. [1 ]
Parnell, Steven R. [1 ]
Parra-Robles, Juan [1 ]
Wild, Jim M. [1 ]
机构
[1] Univ Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
(3)helium; compressed sensing; hyperpolarized; lungs; MRI; 2D; VENTILATION; RESOLUTION;
D O I
10.1002/mrm.22302
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work, the application of compressed sensing techniques to the acquisition and reconstruction of hyperpolarized He-3 lung MR images was investigated. The sparsity of He-3 lung images in the wavelet domain was investigated through simulations based on fully sampled Cartesian two-dimensional and three-dimensional He-3 lung ventilation images, and the k-spaces of 2D and 3D images were undersampled randomly and reconstructed by minimizing the L1 norm. The simulation results show that temporal resolution can be readily improved by a factor of 2 for two-dimensional and 4 to 5 for three-dimensional ventilation imaging with He-3 with the levels of signal to noise ratio (SNR) (similar to 19) typically obtained. The feasibility of producing accurate functional apparent diffusion coefficient (ADC) maps from undersampled data acquired with fewer radio-frequency pulses was also demonstrated, with the preservation of quantitative information (mean ADC(cs) similar to mean ADC(ful) similar to 0.16 cm(2) sec(-1)). Prospective acquisition of 2-fold undersampled two-dimensional He-3 images with a compressed sensing k-space pattern was then demonstrated in a healthy volunteer, and the results were compared to the equivalent fully sampled images (SNRcs = 34, SNRfull = 19). Magn Reson Med 63:1059-1069, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1059 / 1069
页数:11
相关论文
共 21 条
[11]   Signal dynamics in magnetic resonance imaging of the lung with hyperpolarized noble gases [J].
Möller, HE ;
Chen, XJ ;
Chawla, MS ;
Driehuys, B ;
Hedlund, LW ;
Johnson, GA .
JOURNAL OF MAGNETIC RESONANCE, 1998, 135 (01) :133-143
[12]  
MUGLER JP, 2005, P INT SOC MAG RES ME
[13]  
MUGLER JP, 1998, P 6 ISMRM
[14]   Dynamic spiral MRI of pulmonary gas flow using hyperpolarized 3He:: Preliminary studies in healthy and diseased lungs [J].
Salerno, M ;
Altes, TA ;
Brookeman, JR ;
de Lange, EE ;
Mugler, JP .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :667-677
[15]   Functional MRI of the lung using hyperpolarized 3-helium gas [J].
van Beek, EJR ;
Wild, JM ;
Kauczor, HU ;
Schreiber, W ;
Mugler, JP ;
de Lange, EE .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (04) :540-554
[16]   Single-scan acquisition of registered hyperpolarized 3He ventilation and ADC images using a hybrid 2D gradient-echo sequence [J].
Wild, Jim M. ;
Woodhouse, Neil ;
Teh, Kevin .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1185-1189
[17]   3D volume-localized pO2, measurement in the human lung with 3He MRI [J].
Wild, JM ;
Fichele, S ;
Woodhouse, N ;
Paley, MNJ ;
Kasuboski, L ;
van Beek, JR .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) :1055-1064
[18]   Comparison between 2D and 3D gradient-echo sequences for MRI of human lung ventilation with hyperpolarized 3He [J].
Wild, JM ;
Woodhouse, N ;
Paley, MNJ ;
Fichele, S ;
Said, Z ;
Kasuboski, L ;
van Beek, EJR .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) :673-678
[19]   Dynamic radial projection MRI of inhaled hyperpolarized 3He gas [J].
Wild, JM ;
Paley, MNJ ;
Kasuboski, L ;
Swift, A ;
Fichele, S ;
Woodhouse, N ;
Griffiths, PD ;
van Beek, EJR .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) :991-997
[20]   k-space filtering in 2D gradient-echo breath-hold hyperpolarized 3He MRI:: Spatial resolution and signal-to-noise ratio considerations [J].
Wild, JM ;
Paley, MNJ ;
Viallon, M ;
Schreiber, WG ;
van Beek, EJR ;
Griffiths, PD .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :687-695