机构:
Univ Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, EnglandUniv Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, England
Ajraoui, Salma
[1
]
Lee, Kuan J.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, EnglandUniv Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, England
Lee, Kuan J.
[1
]
Deppe, Martin H.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, EnglandUniv Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, England
Deppe, Martin H.
[1
]
Parnell, Steven R.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, EnglandUniv Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, England
Parnell, Steven R.
[1
]
Parra-Robles, Juan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, EnglandUniv Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, England
Parra-Robles, Juan
[1
]
Wild, Jim M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, EnglandUniv Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, England
Wild, Jim M.
[1
]
机构:
[1] Univ Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, England
In this work, the application of compressed sensing techniques to the acquisition and reconstruction of hyperpolarized He-3 lung MR images was investigated. The sparsity of He-3 lung images in the wavelet domain was investigated through simulations based on fully sampled Cartesian two-dimensional and three-dimensional He-3 lung ventilation images, and the k-spaces of 2D and 3D images were undersampled randomly and reconstructed by minimizing the L1 norm. The simulation results show that temporal resolution can be readily improved by a factor of 2 for two-dimensional and 4 to 5 for three-dimensional ventilation imaging with He-3 with the levels of signal to noise ratio (SNR) (similar to 19) typically obtained. The feasibility of producing accurate functional apparent diffusion coefficient (ADC) maps from undersampled data acquired with fewer radio-frequency pulses was also demonstrated, with the preservation of quantitative information (mean ADC(cs) similar to mean ADC(ful) similar to 0.16 cm(2) sec(-1)). Prospective acquisition of 2-fold undersampled two-dimensional He-3 images with a compressed sensing k-space pattern was then demonstrated in a healthy volunteer, and the results were compared to the equivalent fully sampled images (SNRcs = 34, SNRfull = 19). Magn Reson Med 63:1059-1069, 2010. (C) 2010 Wiley-Liss, Inc.