Attenuation-based kV pair selection in dual source dual energy computed tomography angiography of the chest: impact on radiation dose and image quality

被引:7
作者
Renapurkar, Rahul D. [1 ]
Primak, Andrew [2 ]
Azok, Joseph [1 ]
Lempel, Jason [1 ]
Tandon, Yasmeen [3 ]
Bullen, Jennifer [4 ]
Dong, Frank [5 ]
Karim, Wadih [1 ]
Graham, Ruffin [1 ]
机构
[1] Cleveland Clin, Imaging Inst, Thorac Imaging, L10,9500 Euclid Ave, Cleveland, OH 44195 USA
[2] Siemens Med Solut, Malvern, PA USA
[3] Case Western Reserve Univ, Dept Radiol, Metro Hlth Med Ctr, Cleveland, OH 44109 USA
[4] Cleveland Clin, Quantitat Hlth Sci, 9500 Euclid Ave, Cleveland, OH 44195 USA
[5] Cleveland Clin, Sect Med Phys, Cleveland, OH 44106 USA
关键词
Dual energy CT; CT angiography; Pulmonary embolism; CARE kV; Attenuation; TUBE VOLTAGE SELECTION; ITERATIVE RECONSTRUCTION; CLINICAL-APPLICATIONS; POTENTIAL SELECTION; CT ANGIOGRAPHY; PULMONARY; PERFUSION; EXPOSURE; VOLUME;
D O I
10.1007/s00330-016-4714-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the impact of attenuation-based kilovoltage (kV) pair selection in dual source dual energy (DSDE)-pulmonary embolism (PE) protocol examinations on radiation dose savings and image quality. A prospective study was carried out on 118 patients with suspected PE. In patients in whom attenuation-based kV pair selection selected the 80/140Sn kV pair, the pre-scan 100/140Sn CTDIvol (computed tomography dose index volume) values were compared with the pre-scan 80/140Sn CTDIvol values. Subjective and objective image quality parameters were assessed. Attenuation-based kV pair selection switched to the 80/140Sn kV pair ("switched" cohort) in 63 out of 118 patients (53%). The mean 100/140Sn pre-scan CTDIvol was 8.8 mGy, while the mean 80/140Sn pre-scan CTDIvol was 7.5 mGy. The average estimated dose reduction for the "switched" cohort was 1.3 mGy (95% CI 1.2, 1.4; p < 0.001), representing a 15% reduction in dose. After adjusting for patient weight, mean attenuation was significantly higher in the "switched" vs. "non-switched" cohorts in all five pulmonary arteries and in all lobes on iodine maps. This study demonstrates that attenuation-based kV pair selection in DSDE examination is feasible and can offer radiation dose reduction without compromising image quality. aEuro cent Attenuation-based kV pair selection in dual energy examination is feasible. aEuro cent It can offer radiation dose reduction to approximately 50% of patients. aEuro cent Approximate 15% reduction in radiation dose was achieved using this technique. aEuro cent The image quality is not compromised by use of attenuation-based kV pair selection.
引用
收藏
页码:3283 / 3289
页数:7
相关论文
共 24 条
[1]   Prognostic value of perfusion defect volume at dual energy CTA in patients with pulmonary embolism: Correlation with CTA obstruction scores, CT parameters of right ventricular dysfunction and adverse clinical outcome [J].
Apfaltrer, Paul ;
Bachmann, Valentin ;
Meyer, Mathias ;
Henzler, Thomas ;
Barraza, John M. ;
Gruettner, Joachim ;
Walter, Thomas ;
Schoepf, U. Joseph ;
Schoenberg, Stefan O. ;
Fink, Christian .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) :3592-3597
[2]   Estimated Patient Dose Indexes in Adult and Pediatric MDCT: Comparison of Automatic Tube Voltage Selection With Fixed Tube Current, Fixed Tube Voltage, and Weight-Based Protocols [J].
Baker, Mark E. ;
Karim, Wadih ;
Bullen, Jennifer A. ;
Primak, Andrew N. ;
Dong, Frank F. ;
Herts, Brian R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (03) :592-598
[3]   First Clinical Evaluation of High-Pitch Dual-Source Computed Tomographic Angiography Comparing Automated Tube Potential Selection With Automated Tube Current Modulation [J].
Beeres, Martin ;
Williams, Kimberly ;
Bauer, Ralf W. ;
Scholtz, Jan ;
Kaup, Moritz ;
Gruber-Rouh, Tatjana ;
Lee, Clara ;
Wichmann, Julian L. ;
Frellesen, Claudia ;
Nour-Eldin, Nour-Eldin A. ;
Vogl, Thomas J. ;
Kerl, Josef Matthias ;
Bodelle, Boris .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (04) :624-628
[4]  
de Broucker T, 2012, Diagn Interv Imaging, V93, P852, DOI 10.1016/j.diii.2012.07.009
[5]   Attenuation-based automatic kilovolt (kV)-selection in computed tomography of the chest: Effects on radiation exposure and image quality [J].
Eller, Achim ;
Wuest, Wolfgang ;
Scharf, Michael ;
Brand, Michael ;
Achenbach, Stephan ;
Uder, Michael ;
Lell, Michael M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) :2386-2391
[6]   Chronic Thromboembolic Pulmonary Hypertension [J].
Fedullo, Peter ;
Kerr, Kim M. ;
Kim, Nick H. ;
Auger, William R. .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183 (12) :1605-1613
[7]   Dual-Energy CT Angiography for Assessment of Regional Pulmonary Perfusion in Patients With Chronic Thromboembolic Pulmonary Hypertension: Initial Experience [J].
Hoey, Edward T. D. ;
Mirsadraee, Saeed ;
Pepke-Zaba, Joanna ;
Jenkins, David P. ;
Gopalan, Deepa ;
Screaton, Nicholas J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (03) :524-532
[8]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628
[9]   Dual-Energy CT: Clinical Applications in Various Pulmonary Diseases [J].
Kang, Mi-Jin ;
Park, Chang Min ;
Lee, Chang-Hyun ;
Goo, Jin Mo ;
Lee, Hyun Ju .
RADIOGRAPHICS, 2010, 30 (03) :685-698
[10]  
McCollough C, 2014, AAPM REP, P6